1,152 research outputs found

    Subarcsecond Submillimeter Imaging of the Ultracompact HII Region G5.89-0.39

    Full text link
    We present the first subarcsecond submillimeter images of the enigmatic ultracompact HII region (UCHII) G5.89-0.39. Observed with the SMA, the 875 micron continuum emission exhibits a shell-like morphology similar to longer wavelengths. By using images with comparable angular resolution at five frequencies obtained from the VLA archive and CARMA, we have removed the free-free component from the 875 micron image. We find five sources of dust emission: two compact warm objects (SMA1 and SMA2) along the periphery of the shell, and three additional regions further out. There is no dust emission inside the shell, supporting the picture of a dust-free cavity surrounded by high density gas. At subarcsecond resolution, most of the molecular gas tracers encircle the UCHII region and appear to constrain its expansion. We also find G5.89-0.39 to be almost completely lacking in organic molecular line emission. The dust cores SMA1 and SMA2 exhibit compact spatial peaks in optically-thin gas tracers (e.g. 34SO2), while SMA1 also coincides with 11.9 micron emission. In CO(3-2), we find a high-velocity north/south bipolar outflow centered on SMA1, aligned with infrared H2 knots, and responsible for much of the maser activity. We conclude that SMA1 is an embedded intermediate mass protostar with an estimated luminosity of 3000 Lsun and a circumstellar mass of ~1 Msun. Finally, we have discovered an NH3 (3,3) maser 12 arcsec northwest of the UCHII region, coincident with a 44 GHz CH3OH maser, and possibly associated with the Br gamma outflow source identified by Puga et al. (2006).Comment: 41 pages, 11 figures, published in The Astrophysical Journal (2008) Volume 680, Issue 2, pp. 1271-1288. An error in the registration of the marker positions in Figure 11 has been corrected in this versio

    OH-selected AGB and post-AGB stellar objects II.Blue versus red evolution off the AGB

    Get PDF
    Using objects found in a systematic survey of the galactic Plane in the 1612-MHz OH line, we discuss in detail two ``sequences'' of post-AGB evolution, a red and a blue. We argue that the red and the blue groups separate by initial mass at 4Msun, based on evolutionary-sequence turn-off colours, spectral energy distributions, outflow velocities and scaleheight. The higher-mass (blue) objects may have earlier AGB termination. The lower-mass (red) objects undergo very sudden reddening for IRAS colour R21\sim1.2; these sources must all undergo a very similar process at AGB termination. The transition colour corresponds to average initial masses of 1.7Msun. A combined IRAS-MSX colour proves a very sensitive tool to distinguish lower-mass, early post-AGB objects from sources still on the AGB and also to distinguish more evolved post-AGB objects from star-forming regions. The high-mass blue objects are the likely precursors of bipolar planetary nebulae, whereas the low-mass red objects will evolve into elliptical planetary nebulae.Comment: 12 pages, LaTex, 7 figures (1 colour), AJ (accepted

    OH-selected AGB and post-AGB objects I.Infrared and maser properties

    Full text link
    Using 766 compact objects from a survey of the galactic Plane in the 1612-MHz OH line, new light is cast on the infrared properties of evolved stars on the TP-AGB and beyond. The usual mid-infrared selection criteria, based on IRAS colours, largely fail to distinguish early post-AGB stages. A two-colour diagram from narrower-band MSX flux densities, with bimodal distributions, provides a better tool to do the latter. Four mutually consistent selection criteria for OH-masing red PPNe are given, as well as two for early post-AGB masers and one for all post--AGB masers, including the earliest ones. All these criteria miss a group of blue, high-outflow post-AGB sources with 60-mum excess; these will be discussed in detail in Paper II. The majority of post-AGB sources show regular double-peaked spectra in the OH 1612-MHz line, with fairly low outflow velocities, although the fractions of single peaks and irregular spectra may vary with age and mass. The OH flux density shows a fairly regular relation with the stellar flux and the envelope optical depth, with the maser efficiency increasing with IRAS colour R21. The OH flux density is linearly correlated with the 60-mum flux density.Comment: 16 pages, LaTex, 22 figures, AJ (accepted

    A Spitzer IRS Spectral Atlas of Luminous 8 micron Sources in the Large Magellanic Cloud

    Full text link
    We present an atlas of Spitzer Space Telescope Infrared Spectrograph (IRS) spectra of highly luminous, compact mid-infrared sources in the Large Magellanic Cloud. Sources were selected on the basis of infrared colors and 8 micron (MSX) fluxes indicative of highly evolved, intermediate- to high-mass stars with current or recent mass loss at large rates. We determine the chemistry of the circumstellar envelope from the mid-IR continuum and spectral features and classify the spectral types of the stars. In the sample of 60 sources, we find 21 Red Supergiants (RSGs), 16 C-rich Asymptotic Giant Branch (AGB) stars, 11 HII regions, 4 likely O-rich AGB stars, 4 Galactic O-rich AGB stars, 2 OH/IR stars, and 2 B[e] supergiants with peculiar IR spectra. We find that the overwhelming majority of the sample AGB stars (with typical IR luminosities ~1.0E4 L_sun) have C-rich envelopes, while the O-rich objects are predominantly luminous RSGs with L_IR ~ 1.0E5 L_sun. We determine mean bolometric corrections to the stellar K-band flux densities and find that for carbon stars, the bolometric corrections depend on the infrared color, whereas for RSGs, the bolometric correction is independent of IR color. Our results reveal that objects previously classified as PNe on the basis of IR colors are in fact compact HII regions with very red IRS spectra that include strong atomic recombination lines and PAH emission features. We demonstrate that the IRS spectral classes in our sample separate clearly in infrared color-color diagrams that use combinations of 2MASS data and synthetic IRAC/MIPS fluxes derived from the IRS spectra. On this basis, we suggest diagnostics to identify and classify, with high confidence levels, IR-luminous evolved stars and HII regions in nearby galaxies using Spitzer and near-infrared photometry.Comment: 46 pages, 9 figures; accepted for publication in AJ; abstract abridge

    Hipparcos period-luminosity relations for Miras and semiregular variables

    Full text link
    We present period-luminosity diagrams for nearby Miras and semiregulars, selecting stars with parallaxes better than 20 per cent and well-determined periods. Using K-band magnitudes, we find two well-defined P-L sequences, one corresponding to the standard Mira P-L relation and the second shifted to shorter periods by a factor of about 1.9. The second sequence only contains semiregular variables, while the Mira sequence contains both Miras and semiregulars. Several semiregular stars show double periods in agreement with both relations. The Whitelock evolutionary track is shown to fit the data, indicating that the semiregulars are Mira progenitors. The transition between the two sequences may correspond to a change in pulsation mode or to a change in the stellar structure. Large amplitude pulsations leading to classical Mira classification occur mainly near the tip of the local AGB luminosity function.Comment: 10 pages with figures, accepted by ApJ Letter

    Reliability of the Q Force; a mobile instrument for measuring isometric quadriceps muscle strength

    Get PDF
    BACKGROUND: The ability to generate muscle strength is a pre-requisite for all human movement. Decreased quadriceps muscle strength is frequently observed in older adults and is associated with a decreased performance and activity limitations. To quantify the quadriceps muscle strength and to monitor changes over time, instruments and procedures with a sufficient reliability are needed. The Q Force is an innovative mobile muscle strength measurement instrument suitable to measure in various degrees of extension. Measurements between 110 and 130° extension present the highest values and the most significant increase after training. The objective of this study is to determine the test-retest reliability of muscle strength measurements by the Q Force in older adults in 110° extension. METHODS: Forty-one healthy older adults, 13 males and 28 females were included in the study. Mean (SD) age was 81.9 (4.89) years. Isometric muscle strength of the Quadriceps muscle was assessed with the Q Force at 110° of knee extension. Participants were measured at two sessions with a three to eight day interval between sessions. To determine relative reliability, the intraclass correlation coefficient (ICC) was calculated. To determine absolute reliability, Bland and Altman Limits of Agreement (LOA) were calculated and t-tests were performed. RESULTS: Relative reliability of the Q Force is good to excellent as all ICC coefficients are higher than 0.75. Generally a large 95 % LOA, reflecting only moderate absolute reliability, is found as exemplified for the peak torque left leg of -18.6 N to 33.8 N and the right leg of -9.2 N to 26.4 N was between 15.7 and 23.6 Newton representing 25.2 % to 39.9 % of the size of the mean. Small systematic differences in mean were found between measurement session 1 and 2. CONCLUSION: The present study shows that the Q Force has excellent relative test-retest reliability, but limited absolute test-retest reliability. Since the Q Force is relatively cheap and mobile it is suitable for application in various clinical settings, however, its capability to detect changes in muscle force over time is limited but comparable to existing instruments

    Revealing the mid-infrared emission structure of IRAS 16594-4656 and IRAS 07027-7934

    Full text link
    TIMMI2 diffraction-limited mid-infrared images of a multipolar proto-planetary nebula IRAS 16594-4656 and a young [WC] elliptical planetary nebula IRAS 07027-7934 are presented. Their dust shells are for the first time resolved (only marginally in the case of IRAS 07027-7934) by applying the Lucy-Richardson deconvolution algorithm to the data, taken under exceptionally good seeing conditions (<0.5"). IRAS 16594-4656 exhibits a two-peaked morphology at 8.6, 11.5 and 11.7 microns which is mainly attributed to emission from PAHs. Our observations suggest that the central star is surrounded by a toroidal structure observed edge-on with a radius of 0.4" (~640 AU at an assumed distance of 1.6 kpc) with its polar axis at P.A.~80 degrees, coincident with the orientation defined by only one of the bipolar outflows identified in the HST optical images. We suggest that the material expelled from the central source is currently being collimated in this direction and that the multiple outflow formation has not been coeval. IRAS 07027-7934 shows a bright, marginally extended emission (FWHM=0.3") in the mid-infrared with a slightly elongated shape along the N-S direction, consistent with the morphology detected by HST in the near-infrared. The mid-infrared emission is interpreted as the result of the combined contribution of small, highly ionized PAHs and relatively hot dust continuum. We propose that IRAS 07027-7934 may have recently experienced a thermal pulse (likely at the end of the AGB) which has produced a radical change in the chemistry of its central star.Comment: 35 pages, 8 figures (figures 1, 2, 4 and 6 are in low resolution) accepted for publication in Ap

    Spitzer Space Telescope spectral observations of AGB stars in the Fornax dwarf spheroidal galaxy

    Get PDF
    We have observed five carbon-rich AGB stars in the Fornax dwarf spheroidal (dSph) galaxy, using the Infrared Spectrometer on board the Spitzer Space Telescope. The stars were selected from a near-infrared survey of Fornax and include the three reddest stars, with presumably the highest mass-loss rates, in that galaxy. Such carbon stars probably belong to the intermediate-age population (2-8 Gyr old and metallicity of [Fe/H] -1) of Fornax. The primary aim of this paper is to investigate mass-loss rate, as a function of luminosity and metallicity, by comparing AGB stars in several galaxies with different metallicities. The spectra of three stars are fitted with a radiative transfer model. We find that mass-loss rates of these three stars are 4-7x10^-6 Msun yr-1. The other two stars have mass-loss rates below 1.3x10^-6 Msun yr-1. We find no evidence that these rates depend on metallicity, although we do suggest that the gas-to-dust ratio could be higher than at solar metallicity, in the range 240 to 800. The C2H2 bands are stronger at lower metallicity because of the higher C/O ratio. In contrast, the SiC fraction is reduced at low metallicity, due to low silicon abundance. The total mass-loss rate from all known carbon-rich AGB stars into the interstellar medium of this galaxy is of the order of 2x10^-5 Msun yr-1. This is much lower than that of the dwarf irregular galaxy WLM, which has a similar visual luminosity and metallicity. The difference is attributed to the younger stellar population of WLM. The suppressed gas-return rate to the ISM accentuates the difference between the relatively gas-rich dwarf irregular and the gas-poor dwarf spheroidal galaxies. Our study will be useful to constrain gas and dust recycling processes in low metallicity galaxies.Comment: MNRAS accepte

    Survey of Planetary Nebulae at 30 GHz with OCRA-p

    Full text link
    We report the results of a survey of 442 planetary nebulae at 30 GHz. The purpose of the survey is to develop a list of planetary nebulae as calibration sources which could be used for high frequency calibration in future. For 41 PNe with sufficient data, we test the emission mechanisms in order to evaluate whether or not spinning dust plays an important role in their spectra at 30 GHz. The 30-GHz data were obtained with a twin-beam differencing radiometer, OCRA-p, which is in operation on the Torun 32-m telescope. Sources were scanned both in right ascension and declination. We estimated flux densities at 30 GHz using a free-free emission model and compared it with our data. The primary result is a catalogue containing the flux densities of 93 planetary nebulae at 30 GHz. Sources with sufficient data were compared with a spectral model of free-free emission. The model shows that free-free emission can generally explain the observed flux densities at 30 GHz thus no other emission mechanism is needed to account for the high frequency spectra.Comment: 10 pages, 7 Postscript figures, to be published in A&

    Retention, savings and interlimb transfer of reactive gait adaptations in humans following unexpected perturbations

    Get PDF
    Reactive locomotor adaptations are crucial for safe mobility, but remain relatively unexplored. Here we assess reactive gait adaptations, and their retention, savings and interlimb transfer. Using new methods to normalise walking speed and perturbation magnitude, we expose eighteen healthy adults to ten unexpected treadmill belt accelerations during walking (the first and last perturbing the right leg, the others perturbing the left leg) on two days, one month apart. Analysis of the margins of stability using kinematic data reveals that humans reactively adapt gait, improving stability and taking fewer recovery steps, and fully retain these adaptations over time. On re-exposure, retention and savings lead to further improvements in stability. Currently, the role of interlimb transfer is unclear. Our findings show that humans utilise retention and savings in reactive gait adaptations to benefit stability, but that interlimb transfer may not be exclusively responsible for improvements following perturbations to the untrained limb
    corecore