112 research outputs found

    Single-shot real-time femtosecond imaging of temporal focusing

    Get PDF
    While the concept of focusing usually applies to the spatial domain, it is equally applicable to the time domain. Real-time imaging of temporal focusing of single ultrashort laser pulses is of great significance in exploring the physics of the space–time duality and finding diverse applications. The drastic changes in the width and intensity of an ultrashort laser pulse during temporal focusing impose a requirement for femtosecond-level exposure to capture the instantaneous light patterns generated in this exquisite phenomenon. Thus far, established ultrafast imaging techniques either struggle to reach the desired exposure time or require repeatable measurements. We have developed single-shot 10-trillion-frame-per-second compressed ultrafast photography (T-CUP), which passively captures dynamic events with 100-fs frame intervals in a single camera exposure. The synergy between compressed sensing and the Radon transformation empowers T-CUP to significantly reduce the number of projections needed for reconstructing a high-quality three-dimensional spatiotemporal datacube. As the only currently available real-time, passive imaging modality with a femtosecond exposure time, T-CUP was used to record the first-ever movie of non-repeatable temporal focusing of a single ultrashort laser pulse in a dynamic scattering medium. T-CUP’s unprecedented ability to clearly reveal the complex evolution in the shape, intensity, and width of a temporally focused pulse in a single measurement paves the way for single-shot characterization of ultrashort pulses, experimental investigation of nonlinear light-matter interactions, and real-time wavefront engineering for deep-tissue light focusing

    Single-shot stereo-polarimetric compressed ultrafast photography for light-speed observation of high-dimensional optical transients with picosecond resolution

    Get PDF
    Simultaneous and efficient ultrafast recording of multiple photon tags contributes to high-dimensional optical imaging and characterization in numerous fields. Existing high-dimensional optical imaging techniques that record space and polarization cannot detect the photon’s time of arrival owing to the limited speeds of the state-of-the-art electronic sensors. Here, we overcome this long-standing limitation by implementing stereo-polarimetric compressed ultrafast photography (SP-CUP) to record light-speed high-dimensional events in a single exposure. Synergizing compressed sensing and streak imaging with stereoscopy and polarimetry, SP-CUP enables video-recording of five photon tags (x, y, z: space; t: time of arrival; and ψ: angle of linear polarization) at 100 billion frames per second with a picosecond temporal resolution. We applied SP-CUP to the spatiotemporal characterization of linear polarization dynamics in early-stage plasma emission from laser-induced breakdown. This system also allowed three-dimensional ultrafast imaging of the linear polarization properties of a single ultrashort laser pulse propagating in a scattering medium

    Multiview optical resolution photoacoustic microscopy

    Get PDF
    Optical resolution photoacoustic microscopy (OR-PAM), while providing high lateral resolution, has been limited by its relatively poor acoustically determined axial resolution. Although this limitation has been tackled in recent works by using either broadband acoustic detection or nonlinear photoacoustic effects, a flexible solution with three-dimensional optical resolution in reflection mode remains desired. Herein we present a multiview OR-PAM technique. By imaging the sample from multiple view angles and reconstructing the data using a multiview deconvolution method, we have experimentally demonstrated an isotropic optical resolution in three dimensions

    Label-free high-throughput photoacoustic tomography of suspected circulating melanoma tumor cells in patients in vivo

    Get PDF
    Significance: Detection and characterization of circulating tumor cells (CTCs), a key determinant of metastasis, are critical for determining risk of disease progression, understanding metastatic pathways, and facilitating early clinical intervention. Aim: We aim to demonstrate label-free imaging of suspected melanoma CTCs. Approach: We use a linear-array-based photoacoustic tomography system (LA-PAT) to detect melanoma CTCs, quantify their contrast-to-noise ratios (CNRs), and measure their flow velocities in most of the superficial veins in humans. Results: With LA-PAT, we successfully imaged suspected melanoma CTCs in patients in vivo, with a CNR >9. CTCs were detected in 3 of 16 patients with stage III or IV melanoma. Among the three CTC-positive patients, two had disease progression; among the 13 CTC-negative patients, 4 showed disease progression. Conclusions: We suggest that LA-PAT can detect suspected melanoma CTCs in patients in vivo and has potential clinical applications for disease monitoring in melanoma

    Multiview Hilbert transformation in full-ring transducer array-based photoacoustic computed tomography

    Get PDF
    Based on the photoacoustic (PA) effect, PA tomography directly measures specific optical absorption, i.e., absorbed optical energy per unit volume. We recently developed a full-ring ultrasonic transducer array-based photoacoustic computed tomography (PACT) system for small-animal whole-body imaging. The system has a full-view detection angle and high in-plane resolution (∼100  μm). However, due to the bandpass frequency response of the piezoelectric transducer elements and the limited elevational detection coverage of the full-ring transducer array, the reconstructed images present bipolar (i.e., both positive and negative) pixel values, which cause ambiguities in image interpretation for physicians and biologists. We propose a multiview Hilbert transformation method to recover the unipolar initial pressure for full-ring PACT. The effectiveness of the proposed algorithm was first validated by numerical simulations and then demonstrated with ex vivo mouse brain structural imaging and in vivo mouse whole-body imaging

    Multiview Hilbert transformation for full-view photoacoustic computed tomography using a linear array

    Get PDF
    Due to their low cost, hand-held convenience, wide selection of bandwidths, and ultrasound imaging capability, linear ultrasonic transducer arrays have been widely studied for photoacoustic computed tomography (PACT). As linear-array PACT suffers from a limited view, full-view imaging requires either the transducer or the object to be rotated. So far, both the central frequencies and bandwidth of linear transducer arrays applied in full-view PACT are low, limiting the spatial resolutions of the reconstructed images. Here, we present a multiview high-frequency PACT imaging system implemented with a commercial 40-MHz central frequency linear transducer array. By rotating the object through multiple angles with respect to the linear transducer array, we acquired full-view photoacoustic pressure measurements. Further, to quantify the unipolar initial pressures and overcome the limitations of the single-view Hilbert transformation, we developed a multiview Hilbert transformation method. The in-plane spatial resolution of this full-view linear-array PACT was quantified to be isotropically 60 μm within a 10×10  mm^2 field of view. The system was demonstrated by imaging both a leaf skeleton and a zebrafish in vivo

    Improving image quality in compressed ultrafast photography with a space- and intensity-constrained reconstruction algorithm

    Get PDF
    The single-shot compressed ultrafast photography (CUP) camera is the fastest receive-only camera in the world. In this work, we introduce an external CCD camera and a space- and intensity-constrained (SIC) reconstruction algorithm to improve the image quality of CUP. The CCD camera takes a time-unsheared image of the dynamic scene. Unlike the previously used unconstrained algorithm, the proposed algorithm incorporates both spatial and intensity constraints, based on the additional prior information provided by the external CCD camera. First, a spatial mask is extracted from the time-unsheared image to define the zone of action. Second, an intensity threshold constraint is determined based on the similarity between the temporally projected image of the reconstructed datacube and the time-unsheared image taken by the external CCD. Both simulation and experimental studies showed that the SIC reconstruction improves the spatial resolution, contrast, and general quality of the reconstructed image
    • …
    corecore