28 research outputs found

    Direct Signal Detection Without Data‐Aided: A MIMO Functional Network Approach

    Get PDF
    Functional network (FN) has been successfully applied in many fields, but so far no methods of direct signal detection (DSD) using FN have been published. In this chapter, a novel DSD approach using FN, which can be applied to cases with a plural source signal sequence, with short sequence, and even with the absence of a training sequence, is presented. Firstly, a multiple‐input multiple‐output FN (MIMOFN), in which the initial input vector is devised via QR decomposition of the receiving signal matrix, is constructed to solve the special issues of DSD. In the meantime, the design method for the neural function of this special MIMOFN is proposed. Then the learning rule for the parameters of neural functions is trained and updated by back‐propagation (BP) algorithm. The correctness and effectiveness of the new approach are verified by simulation results, together with some special simulation phenomena of the algorithm. The proposed method can detect the source sequence directly from the observed output data by utilizing MIMOFN without a training sequence and estimating the channel impulse response

    Enhancement of Fluorescent Labeling via a Composited Thin Film

    Get PDF
    Fluorescent labeling is the prevailing imaging technique in cell biological research. When statistical investigations on a large number of cells are involved, experimental study is required for both low magnification to get a reliable statistical population and high contrast to achieve accurate diagnosis on the nature of the cells’ perturbation. As microscope objectives of low magnification generally yield low collection efficiency, such studies are limited by the fluorescence signal weakness. To overcome this technological insufficiency, Le Moal et al. proposed a method based on metal-coated substrates that enhanced the fluorescence process and improved collection efficiency in fluorescence microscope observation and that could be directly used with a common microscope setup. In this paper, we use an Ag-Si3N4-Ag multilayer film coated on the substrate and numerically analyse the optical behavior of a fluorophore which was placed above the composited film coated on the substrate. The results shows that by using an Ag-Si3N4-Ag composited film the fluorescence imaging can be enhanced remarkably

    Mid-infrared tunable intracavity singly resonant optical parametric oscillator based on Mgo : PPLN

    No full text
    In this paper, we demonstrated a continuous-wave intracavity singly resonant optical parametric oscillator based on periodically poled MgO:LiNbO3 (MgO:PPLN) pumped by a diode-pumped Nd:YVO4 laser at 1064 nm. The singly resonant optical parametric oscillator only outputs the idler light as its cavity high reflectivity was coated at the signal light. When the temperature was controlled at 120°C and the grating period set at 30.5 μm for the MgO:PPLN, a maximum idler output power of 1.27 W and central wavelength at 3251 nm were obtained under an incident diode pump power of 12.4 W, corresponding to the conversion efficiency of 10.2%. By changing the temperature and the grating period of MgO:PPLN crystal, widely tunable mid-infrared spectra from 2.95 to 4.16 μm were achieved.Published versio

    1.96-μm Tm:YAG Ceramic Laser

    No full text

    Passively Q-Switched KTA Cascaded Raman Laser with 234 and 671 cm−1 Shifts

    No full text
    A compact KTA cascaded Raman system driven by a passively Q-switched Nd:YAG/Cr4+:YAG laser at 1064 nm was demonstrated for the first time. The output spectra with different cavity lengths were measured. Two strong lines with similar intensity were achieved with a 9 cm length cavity. One is the first-Stokes at 1146.8 nm with a Raman shift of 671 cm−1, and the other is the Stokes at 1178.2 nm with mixed Raman shifts of 234 cm−1 and 671 cm−1. At the shorter cavity length of 5 cm, the output Stokes lines with high intensity were still at 1146.8 nm and 1178.2 nm, but the intensity of 1178.2 nm was higher than that of 1146.8 nm. The maximum average output power of 540 mW was obtained at the incident pump power of 10.5 W with the pulse repetition frequency of 14.5 kHz and the pulse width around 1.1 ns. This compact passively Q-switched KTA cascaded Raman laser can yield multi-Stokes waves, which enrich laser output spectra and hold potential applications for remote sensing and terahertz generation

    Mutation EthA(W21R) confers co-resistance to prothionamide and ethionamide in both Mycobacterium bovis BCG and Mycobacterium tuberculosis H37Rv

    No full text
    Ethionamide (ETA) and prothionamide (PRO) are interchangeably used in tuberculosis (TB) chemotherapy regimens. Subtle discrepancies between biochemical and genetic information on the modes of sensitivity and resistance of isoniazid (INH) and ETA warrants further studies. We report a new mutation - EthA(W21R) - in Mycobacterium bovis Bacillus Calmette-Guerin that corresponds with co-resistance to both PRO and ETA, which to the best of our knowledge has not been reported before. Our findings suggest that mutation EthA(W21R) could be used as a marker site for testing PRO and ETA cross-resistance
    corecore