66 research outputs found
Preserving normal facial nerve function and improving hearing outcome in large vestibular schwannomas with a combined approach: planned subtotal resection followed by gamma knife radiosurgery.
To perform planned subtotal resection followed by gamma knife surgery (GKRS) in a series of patients with large vestibular schwannoma (VS), aiming at an optimal functional outcome for facial and cochlear nerves.
Patient characteristics, surgical and dosimetric features, and outcome were collected prospectively at the time of treatment and during the follow-up.
A consecutive series of 32 patients was treated between July 2010 and June 2016. Mean follow-up after surgery was 29 months (median 24, range 4-78). Mean presurgical tumor volume was 12.5 cm3 (range 1.47-34.9). Postoperative status showed normal facial nerve function (House-Brackmann I) in all patients. In a subgroup of 17 patients with serviceable hearing before surgery and in which cochlear nerve preservation was attempted at surgery, 16 (94.1%) retained serviceable hearing. Among them, 13 had normal hearing (Gardner-Robertson class 1) before surgery, and 10 (76.9%) retained normal hearing after surgery. Mean duration between surgery and GKRS was 6.3 months (range 3.8-13.9). Mean tumor volume at GKRS was 3.5 cm3 (range 0.5-12.8), corresponding to mean residual volume of 29.4% (range 6-46.7) of the preoperative volume. Mean marginal dose was 12 Gy (range 11-12). Mean follow-up after GKRS was 24 months (range 3-60). Following GKRS, there were no new neurological deficits, with facial and hearing functions remaining identical to those after surgery in all patients. Three patients presented with continuous growth after GKRS, were considered failures, and benefited from the same combined approach a second time.
Our data suggest that large VS management, with planned subtotal resection followed by GKRS, might yield an excellent clinical outcome, allowing the normal facial nerve and a high level of cochlear nerve functions to be retained. Our functional results with this approach in large VS are comparable with those obtained with GKRS alone in small- and medium-sized VS. Longer term follow-up is necessary to fully evaluate this approach, especially regarding tumor control
Clinical implementation of deep learning-based automated left breast simultaneous integrated boost radiotherapy treatment planning.
Automation in radiotherapy treatment planning aims to improve both the quality and the efficiency of the process. The aim of this study was to report on a clinical implementation of a Deep Learning (DL) auto-planning model for left-sided breast cancer.
The DL model was developed for left-sided breast simultaneous integrated boost treatments under deep-inspiration breath-hold. Eighty manual dose distributions were revised and used for training. Ten patients were used for model validation. The model was then used to design 17 clinical auto-plans. Manual and auto-plans were scored on a list of clinical goals for both targets and organs-at-risk (OARs). For validation, predicted and mimicked dose (PD and MD, respectively) percent error (PE) was calculated with respect to manual dose. Clinical and validation cohorts were compared in terms of MD only.
Median values of both PD and MD validation plans fulfilled the evaluation criteria. PE was < 1% for targets for both PD and MD. PD was well aligned to manual dose while MD left lung mean dose was significantly less (median:5.1 Gy vs 6.1 Gy). The left-anterior-descending artery maximum dose was found out of requirements (median values:+5.9 Gy and + 2.9 Gy, for PD and MD respectively) in three validation cases, while it was reduced for clinical cases (median:-1.9 Gy). No other clinically significant differences were observed between clinical and validation cohorts.
Small OAR differences observed during the model validation were not found clinically relevant. The clinical implementation outcomes confirmed the robustness of the model
Reduction of Respiratory Motion During PET/CT by Pulsatile-Flow Ventilation: A First Clinical Evaluation.
Respiratory motion negatively affects PET/CT image quality and quantitation. A novel Pulsatile-Flow Ventilation (PFV) system reducing respiratory motion was applied in spontaneously breathing patients to induce sustained apnea during PET/CT.
Four patients (aged 65 ± 14 y) underwent PET/CT for pulmonary nodule staging (mean, 11 ± 7 mm; range, 5-18 mm) at 63 ± 3 min after (18)F-FDG injection and then at 47 ± 7 min afterward, during PFV-induced apnea (with imaging lasting ≥8.5 min). Anterior-posterior thoracic amplitude, SUVmax, and SUVpeak (SUVmean in a 1-cm-diameter sphere) were compared.
PFV PET/CT reduced thoracic amplitude (80%), increased mean lesion SUVmax (29%) and SUVpeak (11%), decreased lung background SUVpeak (25%), improved lesion detectability, and increased SUVpeak lesion-to-background ratio (54%). On linear regressions, SUVmax and SUVpeak significantly improved (by 35% and 23%, respectively; P ≤ 0.02).
PFV-induced apnea reduces thoracic organ motion and increases lesion SUV, detectability, and delineation, thus potentially affecting patient management by improving diagnosis, prognostication, monitoring, and external-radiation therapy planning
Hepatobiliary scintigraphy allows the evaluation of short-term functional toxicity of liver stereotactic body radiotherapy: Results of a pilot study.
To study the potential of (99m)Tc-Mebrofenin hepatobiliary scintigraphy (HBS) in identifying the short-term variations of liver function after stereotactic body radiotherapy (SBRT) for liver cancers.
We treated with SBRT 3 patients (pts) affected by a cholangiocarcinoma and 3 patient presenting liver metastases (3x15 Gy, 4 pts; 5x8 Gy, 1 pt; 6x5 Gy, 1 pt). All patients received HBS before and 3 months after SBRT, which were co-registered with the simulation CT-scan. Structures corresponding to isodoses from 10-90 Gy were created, with intervals of 10 Gy. Finally, the variations of the mean activity (MBq) in each isodose structure have been calculated. Then, a linear regression analysis was performed.
We showed a linear reduction of the activity, significantly related to the delivered dose (p<0.01), and a reduction of the perfusion of 0.78% for each delivered Gy. The linear equation has predictive value of the loss of the function of 96% (R2 = 0.9605).
HBS could improve treatment plans for liver SBRT, by allowing the identification of the liver function variations after SBRT and, potentially, the prediction of remnant liver function after SBRT. These preliminary results should be confirmed on long-term prospective data and larger population
Curative management of a cardiac metastasis from lung cancer revealed by an electrical storm.
Although cardiac metastases (CM) are more common than primary cardiac malignant tumors, they remain a rare localization of metastatic cancer. Until recently, CM were surgically treated as a palliative approach because of a lack of ablative solutions even for oligometastatic patients. Technological advances in radiation therapy (RT) in thoracic oncology have led to high precision delivery that enlarged the indications for stereotactic body radiotherapy (SBRT). To date, there are limited reports of cardiac SBRT for CM. Herein, we report a cardiac SBRT performed in curative intent for a lung cancer patient metastatic to the heart
On the interplay effect for moving targets treated with the CyberKnife static tracking system.
To assess the interplay effect amplitude between different planned MU distributions and respiratory patterns in the CyberKnife system when treating moving targets with static tracking technique.
Small- and Large-Respiratory Motions (SRM and LRM) differing in amplitude and frequency were simulated in a semi-anthropomorphic dynamic thorax phantom. The interplay effect was evaluated for both respiration motions in terms of GTV coverage and conformity for three plans designed with an increasing range of MU per beam (small, medium and large). Each plan was delivered three times changing the initial beam-on phase to assess the inter-fraction variation. Dose distributions were measured using radiochromic films placed in the GTV axial and sagittal planes.
Generally, SRM plans gave higher GTV coverage and were less dependent on beam-on phases than LRM plans. For SRM (LRM) plans, the GTV coverage ranged from 95.2% to 99.7% (85.9% to 99.8%). Maximum GTV coverage was found for large MU plans in SRM and for small MU plans in LRM. Minimum GTV coverage was found for medium MU plans for both SRM and LRM. For SRM plans, dose conformity decreased with increasing MU range while the variation was reduced for LRM plans. Large MU plans reduced the inter-fraction variation for SRM and LRM.
We confirmed the interplay effect between target motion and beam irradiation time for CyberKnife static tracking. Plans with large MU per beam improved the GTV coverage for small motion amplitude and the inter-fraction dose variation for large motion amplitude
- …