    Investigation of Axial and Angular Sampling in Multi-Detector Pinhole-SPECT Brain Imaging

    Get PDF
    We designed a dedicated multi-detector multi-pinhole brain SPECT scanner to generate images of higher quality compared to general-purpose systems. The system, AdaptiSPECT-C, is intended to adapt its sensitivity-resolution trade-off by varying its aperture configurations allowing both high-sensitivity dynamic and high-spatial-resolution static imaging. The current system design consists of 23 detector heads arranged in a truncated spherical geometry. In this work, we investigated the axial and angular sampling capability of the current stationary system design. Two data acquisition schemes using limited rotation of the gantry and two others using axial translation of the imaging bed were also evaluated concerning their impact on image quality through improved sampling. Increasing both angular and axial sampling in the current prototype system resulted in quantitative improvements in image quality metrics and qualitative appearance of the images as determined in studies with specifically selected phantoms. Visual improvements for the brain phantoms with clinical distributions were less pronounced but presented quantitative improvements in the fidelity (normalized root-mean-square error (NRMSE)) and striatal specific binding ratio (SBR) for a dopamine transporter (DAT) distribution, and in NRMSE and activity recovery for a brain perfusion distribution. More pronounced improvements with increased sampling were seen in contrast recovery coefficient, bias, and coefficient of variation for a lesion in the brain perfusion distribution. The negligible impact of the most cranial ring of detectors on axial sampling, but its significant impact on sensitivity and angular sampling in the cranial portion of the imaging volume-of-interest were also determined

    Inclusion of quasi-vertex views in a brain-dedicated multi-pinhole SPECT system for improved imaging performance

    Get PDF
    With brain-dedicated multi-detector systems employing pinhole apertures the usage of detectors facing the top of the patient\u27s head (i.e., quasi-vertex views) can provide the advantage of additional viewing from close to the brain for improved detector coverage. In this paper, we report the results of simulation and reconstruction studies to investigate the impact of the quasi-vertex views on the imaging performance of AdaptiSPECT-C, a brain-dedicated stationary SPECT system under development. In this design, both primary and scatter photons from regions located inferior to the brain can contribute to SPECT projections acquired by the quasi-vertex views, and thus degrade AdaptiSPECT-C imaging performance. In this work, we determined the proportion, origin, and nature (i.e., primary, scatter, and multiple-scatter) of counts emitted from structures within the head and throughout the body contributing to projections from the different AdaptiSPECT-C detector rings, as well as from a true vertex view detector. We simulated phantoms used to assess different aspects of image quality (i.e., uniform sphere and Derenzo), as well as anthropomorphic phantoms with multiple count levels emulating clinical(123)I activity distributions (i.e., DaTscan and perfusion). We determined that attenuation and scatter in the patient\u27s body greatly diminish the probability of the photons emitted outside the volume of interest reaching to detectors and being recorded within the 15% photopeak energy window. In addition, we demonstrated that the inclusion of the residual of such counts in the system acquisition does not degrade visual interpretation or quantitative analysis. The addition of the quasi-vertex detectors increases volumetric sensitivity, angular sampling, and spatial resolution leading to significant enhancement in image quality, especially in the striato-thalamic and superior regions of the brain. Besides, the use of quasi-vertex detectors improves the recovery of clinically relevant metrics such as the striatal binding ratio and mean activity in selected cerebral structures

    GPU-accelerated generic analytic simulation and image reconstruction platform for multi-pinhole SPECT systems

    No full text
    We introduce a generic analytic simulation and image reconstruction software platform for multi-pinhole (MPH) SPECT systems. The platform is capable of modeling common or sophisticated MPH designs as well as complex data acquisition schemes. Graphics processing unit (GPU) acceleration was utilized to make a high-performance computing software. Herein, we describe the software platform and provide verification studies of the simulation and image reconstruction software.This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]

    Investigation of a Monte Carlo simulation and an analytic-based approach for modeling the system response for clinical I-123 brain SPECT imaging

    No full text
    The use of accurate system response modeling has been proven to be an essential key of SPECT image reconstruction, with its usage leading to overall improvement of image quality. The aim of this work was to investigate the imaging performance using an XCAT brain perfusion phantom of two modeling strategies, one based on analytic techniques and the other one based on GATE Monte-Carlo simulation. In addition, an efficient forced detection approach to improve the overall simulation efficiency was implemented and its performance was evaluated. We demonstrated that accurate modeling of the system matrix generated by Monte-Carlo simulation for iterative reconstruction leads to superior performance compared to analytic modeling in the case of clinical I-123 brain imaging. It was also shown that the use of the forced detection approach provided a quantitative and qualitative enhancement of the reconstruction.This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]

    Investigation of a Monte Carlo simulation and an analytic-based approach for modeling the system response for clinical I-123 brain SPECT imaging

    No full text
    The use of accurate system response modeling has been proven to be an essential key of SPECT image reconstruction, with its usage leading to overall improvement of image quality. The aim of this work was to investigate the imaging performance using an XCAT brain perfusion phantom of two modeling strategies, one based on analytic techniques and the other one based on GATE Monte-Carlo simulation. In addition, an efficient forced detection approach to improve the overall simulation efficiency was implemented and its performance was evaluated. We demonstrated that accurate modeling of the system matrix generated by Monte-Carlo simulation for iterative reconstruction leads to superior performance compared to analytic modeling in the case of clinical I-123 brain imaging. It was also shown that the use of the forced detection approach provided a quantitative and qualitative enhancement of the reconstruction.This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]

    Primary, scatter, and penetration characterizations of parallel-hole and pinhole collimators for I-123 SPECT

    No full text
    Multi-pinhole (MPH) collimators are known to provide better trade-off between sensitivity and resolution for preclinical, as well as for smaller regions in clinical SPECT imaging compared to conventional collimators. In addition to this geometric advantage, MPH plates typically offer better stopping power for penetration than the conventional collimators, which is especially relevant for I-123 imaging. The I-123 emits a series of high-energy ( \u3e 300 keV, ~2.5% abundance) gamma photons in addition to the primary emission (159 keV, 83% abundance). Despite their low abundance, high-energy photons penetrate through a low-energy parallel-hole (LEHR) collimator much more readily than the 159 keV photons, resulting in large downscatter in the photopeak window. In this work, we investigate the primary, scatter, and penetration characteristics of a single pinhole collimator that is commonly used for I-123 thyroid imaging and our two MPH collimators designed for I-123 DaTscan imaging for Parkinson\u27s Disease, in comparison to three different parallel-hole collimators through a series of experiments and Monte Carlo simulations. The simulations of a point source and a digital human phantom with DaTscan activity distribution showed that our MPH collimators provide superior count performance in terms of high primary counts, low penetration, and low scatter counts compared to the parallel-hole and single pinhole collimators. For example, total scatter, multiple scatter, and collimator penetration events for the LEHR were 2.5, 7.6 and 14 times more than that of MPH within the 15% photopeak window. The total scatter fraction for LEHR was 56% where the largest contribution came from the high-energy scatter from the back compartments (31%). For the same energy window, the total scatter for MPH was 21% with only 1% scatter from the back compartments. We therefore anticipate that using MPH collimators, higher quality reconstructions can be obtained in a substantially shorter acquisition time for I-123 DaTscan and thyroid imaging

    Preliminary investigation of AdaptiSPECT-C designs with square or square and hexagonal detectors employing direct and oblique apertures

    No full text
    We report our investigation of system designs and 3D reconstruction for a dedicated brain-imaging SPECT system using multiple square or square and hexagonal detector modules. The system employs shuttering to vary which of multiple pinhole apertures are enabled to pass photons through to irradiate the detectors. Both multiplexed and nonmultiplexed irradiation by the pinholes are investigated. Sampling is assessed by simulated imaging of a uniform activity concentration in a spherical tub filling the VOI and a tailored Defrise phantom consisting of a series of activity containing slabs aligned axially. Potential image quality for clinical imaging is assessed through simulated imaging of an XCAT brain phantom with an activity distribution simulating perfusion imaging.This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]

    Cerebral SPECT imaging with different acquisition schemes using varying levels of multiplexing versus sensitivity in an adaptive multi-pinhole brain-dedicated scanner

    No full text
    Application of multi-pinhole collimator in pinhole-based SPECT increases detection sensitivity. The presence of multiplexing in projection images due to the usage of multiple pinholes can further improve the sensitivity at the cost of adding data ambiguity. We are developing a next-generation adaptive brain-dedicated SPECT system -AdaptiSPECT-C. The AdaptiSPECT-C can adapt the multiplexing level and system sensitivity using adaptable pinhole modules. In this study, we investigated the performance of 4 data acquisition schemes with different multiplexing levels and sensitivities on cerebral SPECT imaging. Schemes #1, #2, and #3 have \u3c 1%, 67%, and 31% overall multiplexing, respectively, while the 4th scheme without multiplexing is considered as ground truth. The ground-truth and schemes #1-3 have 1.0, 1.7, 5.1, and 4.0 times higher sensitivity, respectively, compared to a dual-headed parallel-hole SPECT system at matched spatial resolution. A customized XCAT brain perfusion digital phantom emulating the distribution of I-123 N-isopropyl iodoamphetamine (IMP) in a 99th percentile size male was used for simulations. Data acquisition for each scheme was performed at two count levels (low-count and high-count relative to the recommended clinical count level). The normalized root-mean-square error (NRMSE) for schemes #1, #2, and #3 with the low-count (high-count) scenario showed 11%, 4%, and 5% (10%, 5%, and 6%) deviation, respectively, from that of the multiplex-free ground truth. For both the low-count and high-count scenarios, scheme #1 resulted in the least accurate activity ratio (AR) for almost all the analyzed gray-matter brain regions. Further schemes #2 or #3 led to the most accurate AR values with both low-count and high-count scenarios for all the analyzed gray-matter regions. It was thus observed that even with this large head size which leads to significant multiplexing levels, the higher sensitivity from multiplexing could to some extent mitigate the data ambiguity and be translated into reconstructed images of higher quality