391 research outputs found

    cExternal beam radiation results in minimal changes in post void residual urine volumes during the treatment of clinically localized prostate cancer

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To evaluate the impact of external beam radiation therapy (XRT) on weekly ultrasound determined post-void residual (PVR) urine volumes in patients with prostate cancer.</p> <p>Methods</p> <p>125 patients received XRT for clinically localized prostate cancer. XRT was delivered to the prostate only (n = 66) or if the risk of lymph node involvement was greater than 10% to the whole pelvis followed by a prostate boost (n = 59). All patients were irradiated in the prone position in a custom hip-fix mobilization device with an empty bladder and rectum. PVR was obtained at baseline and weekly. Multiple clinical and treatment parameters were evaluated as predictors for weekly PVR changes.</p> <p>Results</p> <p>The mean patient age was 73.9 years with a mean pre-treatment prostate volume of 53.3 cc, a mean IPSS of 11.3 and a mean baseline PVR of 57.6 cc. During treatment, PVR decreased from baseline in both cohorts with the absolute difference within the limits of accuracy of the bladder scanner. Alpha-blockers did not predict for a lower PVR during treatment. There was no significant difference in mean PVR urine volumes or differences from baseline in either the prostate only or pelvic radiation groups (p = 0.664 and p = 0.458, respectively). Patients with a larger baseline PVR (>40 cc) had a greater reduction in PVR, although the greatest reduction was seen between weeks one and three. Patients with a small PVR (<40 cc) had no demonstrable change throughout treatment.</p> <p>Conclusion</p> <p>Prostate XRT results in clinically insignificant changes in weekly PVR volumes, suggesting that radiation induced bladder irritation does not substantially influence bladder residual urine volumes.</p

    Intensity-modulated radiation therapy: emerging cancer treatment technology

    Get PDF
    The use of intensity-modulated radiation therapy (IMRT) is rapidly advancing in the field of radiation oncology. Intensity-modulated radiation therapy allows for improved dose conformality, thereby affording the potential to decrease the spectrum of normal tissue toxicities associated with IMRT. Preliminary results with IMRT are quite promising; however, the clinical data is relatively immature and overall patient numbers remain small. High-quality IMRT requires intensive physics support and detailed knowledge of three-dimensional anatomy and patterns of tumour spread. This review focuses on basic principles, and highlights the clinical implementation of IMRT in head and neck and prostate cancer

    Biological-effective versus conventional dose volume histograms correlated with late genitourinary and gastrointestinal toxicity after external beam radiotherapy for prostate cancer: a matched pair analysis

    Get PDF
    BACKGROUND: To determine whether the dose-volume histograms (DVH's) for the rectum and bladder constructed using biological-effective dose (BED-DVH's) better correlate with late gastrointestinal (GI) and genitourinary (GU) toxicity after treatment with external beam radiotherapy for prostate cancer than conventional DVH's (C-DVH's). METHODS: The charts of 190 patients treated with external beam radiotherapy with a minimum follow-up of 2 years were reviewed. Six patients (3.2%) were found to have RTOG grade 3 GI toxicity, and similarly 6 patients (3.2%) were found to have RTOG grade 3 GU toxicity. Average late C-DVH's and BED-DVH's of the bladder and rectum were computed for these patients as well as for matched-pair control patients. For each matched pair the following measures of normalized difference in the DVH's were computed: (a) δ(AUC )= (Area Under Curve [AUC] in grade 3 patient – AUC in grade 0 patient)/(AUC in grade 0 patient) and (b) δ(V60 )= (Percent volume receiving = 60 Gy [V60] in grade 3 patient – V60 in grade 0 patient)/(V60 in grade 0 patient). RESULTS: As expected, the grade 3 curve is to the right of and above the grade 0 curve for all four sets of average DVH's – suggesting that both the C-DVH and the BED-DVH can be used for predicting late toxicity. δ(AUC )was higher for the BED-DVH's than for the C-DVH's – 0.27 vs 0.23 (p = 0.036) for the rectum and 0.24 vs 0.20 (p = 0.065) for the bladder. δ(V60 )was also higher for the BED-DVH's than for the C-DVH's – 2.73 vs 1.49 for the rectum (p = 0.021) and 1.64 vs 0.71 (p = 0.021) for the bladder. CONCLUSIONS: When considering well-established dosimetric endpoints used in evaluating treatment plans, BED-DVH's for the rectum and bladder correlate better with late toxicity than C-DVH's and should be considered when attempting to minimize late GI and GU toxicity after external beam radiotherapy for prostate cancer

    Long-term biochemical results after high-dose-rate intensity modulated brachytherapy with external beam radiotherapy for high risk prostate cancer

    Get PDF
    Abstract Background Biochemical control from series in which radical prostatectomy is performed for patients with unfavorable prostate cancer and/or low dose external beam radiation therapy are given remains suboptimal. The treatment regimen of HDR brachytherapy and external beam radiotherapy is a safe and very effective treatment for patients with high risk localized prostate cancer with excellent biochemical control and low toxicity.</p

    Distinct effects of rectum delineation methods in 3D-confromal vs. IMRT treatment planning of prostate cancer

    Get PDF
    BACKGROUND: The dose distribution to the rectum, delineated as solid organ, rectal wall and rectal surface, in 3D conformal (3D-CRT) and intensity-modulated radiotherapy treatment (IMRT) planning for localized prostate cancer was evaluated. MATERIALS AND METHODS: In a retrospective planning study 3-field, 4-field and IMRT treatment plans were analyzed for ten patients with localized prostate cancer. The dose to the rectum was evaluated based on dose-volume histograms of 1) the entire rectal volume (DVH) 2) manually delineated rectal wall (DWH) 3) rectal wall with 3 mm wall thickness (DWH(3)) 4) and the rectal surface (DSH). The influence of the rectal filling and of the seminal vesicles' anatomy on these dose parameters was investigated. A literature review of the dose-volume relationship for late rectal toxicity was conducted. RESULTS: In 3D-CRT (3-field and 4-field) the dose parameters differed most in the mid-dose region: the DWH showed significantly lower doses to the rectum (8.7% ± 4.2%) compared to the DWH(3 )and the DSH. In IMRT the differences between dose parameters were larger in comparison with 3D-CRT. Differences were statistically significant between DVH and all other dose parameters and between DWH and DSH. Mean doses were increased by 23.6% ± 8.7% in the DSH compared to the DVH in the mid-dose region. Furthermore, both the rectal filling and the anatomy of the seminal vesicles influenced the relationship between the dose parameters: a significant correlation of the difference between DVH and DWH and the rectal volume was seen in IMRT treatment. DISCUSSION: The method of delineating the rectum significantly influenced the dose representation in the dose-volume histogram. This effect was pronounced in IMRT treatment planning compared to 3D-CRT. For integration of dose-volume parameters from the literature into clinical practice these results have to be considered

    Intensity modulated radiotherapy for high risk prostate cancer based on sentinel node SPECT imaging for target volume definition

    Get PDF
    BACKGROUND: The RTOG 94-13 trial has provided evidence that patients with high risk prostate cancer benefit from an additional radiotherapy to the pelvic nodes combined with concomitant hormonal ablation. Since lymphatic drainage of the prostate is highly variable, the optimal target volume definition for the pelvic lymph nodes is problematic. To overcome this limitation, we tested the feasibility of an intensity modulated radiation therapy (IMRT) protocol, taking under consideration the individual pelvic sentinel node drainage pattern by SPECT functional imaging. METHODS: Patients with high risk prostate cancer were included. Sentinel nodes (SN) were localised 1.5–3 hours after injection of 250 MBq (99m)Tc-Nanocoll using a double-headed gamma camera with an integrated X-Ray device. All sentinel node localisations were included into the pelvic clinical target volume (CTV). Dose prescriptions were 50.4 Gy (5 × 1.8 Gy / week) to the pelvis and 70.0 Gy (5 × 2.0 Gy / week) to the prostate including the base of seminal vesicles or whole seminal vesicles. Patients were treated with IMRT. Furthermore a theoretical comparison between IMRT and a three-dimensional conformal technique was performed. RESULTS: Since 08/2003 6 patients were treated with this protocol. All patients had detectable sentinel lymph nodes (total 29). 4 of 6 patients showed sentinel node localisations (total 10), that would not have been treated adequately with CT-based planning ('geographical miss') only. The most common localisation for a probable geographical miss was the perirectal area. The comparison between dose-volume-histograms of IMRT- and conventional CT-planning demonstrated clear superiority of IMRT when all sentinel lymph nodes were included. IMRT allowed a significantly better sparing of normal tissue and reduced volumes of small bowel, large bowel and rectum irradiated with critical doses. No gastrointestinal or genitourinary acute toxicity Grade 3 or 4 (RTOG) occurred. CONCLUSION: IMRT based on sentinel lymph node identification is feasible and reduces the probability of a geographical miss. Furthermore, IMRT allows a pronounced sparing of normal tissue irradiation. Thus, the chosen approach will help to increase the curative potential of radiotherapy in high risk prostate cancer patients
    • …
    corecore