90 research outputs found

    Wild edible plant consumption and age-related cataracts in a rural Lebanese elderly population : a case control study

    Get PDF
    Thesis, McGill University, 2007Abstract in English and FrenchAppendices missingThe Mediterranean diet is characterized by considerable diversity and high consumption of wild leafy greens which are excellent sources of antioxidants, including lutein and zeaxanthin. The latter are the only carotenoids present in the human lens and observational and intervention studies suggest they may be protective against age-related cataracts. To better understand the role of dietary diversity in general (and lutein and zeaxanthin in particular) in preventing age-related cataracts and the determinants of wild leafy greens’ consumption, dietary and socioeconomic data were collected from one hundred cases and controls randomly selected from Hermel, a poor and fairly traditional Lebanese rural area. Results showed that dietary diversity and antioxidants (including but not limited to lutein and zeaxanthin) are inversely related to age-related cataracts and that wild leafy greens seem to substantially contribute to protection against age-related cataracts by optimizing nutrient and antioxidant intake especially in those of low socio-economic status

    Knowledge, practice and attitudes regarding antibiotics use among Lebanese dentists

    Get PDF
    Objectives: Explore antibiotic use, assess conformity with evidence-practice guidelines, and describe knowledge and attitudinal factors among Lebanese dentists. Methods: National cross-sectional telephonic survey, using a standardized questionnaire addressing demographic, educational and professional data, usual antibiotics prophylactic and curative prescription pattern and influential factors, knowledge concerning antibiotics use in selected patient-populations, and attitude regarding antimicrobial resistance. Analyses used descriptive statistics, and bivariate analysis to observe predictors of higher knowledge. Results: the overall response rate for the study was around 21%. 322 dentists participated. On average, 17.51% of consultations resulted in antibiotic use; previous antibiotic experience mostly influenced prescriptions (81.3%). Referral of pregnant and lactating women and cardiac patients, when antibiotics are needed, was high (26.9%, 28.5% and 79.4%, respectively). Macrolides were the dominant first-line antibiotics in penicillin allergy (47.4%). Penicillins were most common for pregnant and lactating women. Penicillins (95.0%), 2g (63.9%), and 1 hour pre-procedure (34%) were the main components of prophylaxis for cardiac patients. Prophylactic and curative use varied widely; few dentists exhibited guideline-conform prescriptions. Mean knowledge scores of prophylaxis for cardiac and non-cardiac patients, and antibiotics’ side effects were predominantly poor (46.75±14.82, 39.21±33.09 and 20.27±18.77, respectively over 100). Practicing outside Beirut, undergraduate qualification in Lebanon, and post-graduate qualification predicted higher knowledge. 75.9% acknowledged the contribution of dentistry-based prescribing to antibiotic resistance and 94.7% knew at least one cause of resistance. Conclusions: Dentists show positive attitude towards antimicrobial resistance. Yet, they lack uniformity in antibiotic stewardship. Poor knowledge and guideline-incongruent prophylactic and therapeutic prescribing are observed. Development of targeted interventions is needed to promote judicious antibiotic use within Lebanese dentistry

    SOPROLIFE System: An Accurate Diagnostic Enhancer

    Get PDF
    Objectives. The aim of this study was to evaluate a light-emitting diode fluorescence tool, the SOPROLIFE light-induced fluorescence evaluator, and compare it to the international caries detection and assessment system-II (ICDAS-II) in the detection of occlusal caries. Methods. A total of 219 permanent posterior teeth in 21 subjects, with age ranging from 15 to 65 years, were examined. An intraclass correlation coefficient (ICC) was computed to assess the reliability between the two diagnostic methods. Results. The results showed a high reliability between the two methods (ICC = 0.92; IC = 0.901–0.940; P<0.001). The SOPROLIFE blue fluorescence mode had a high sensitivity (87%) and a high specificity (99%) when compared to ICDAS-II. Conclusion. Compared to the most used visual method in the diagnosis of occlusal caries lesions, the finding from this study suggests that SOPROLIFE can be used as a reproducible and reliable assessment tool. At a cut-off point, categorizing noncarious lesions and visual change in enamel, SOPROLIFE shows a high sensitivity and specificity. We can conclude that financially ICDAS is better than SOPROLIFE. However SOPROLIFE is easier for clinicians since it is a simple evaluation of images. Finally in terms of efficiency SOPROLIFE is not superior to ICDAS but tends to be equivalent with the same advantages

    Insights into water coordination associated with the Cu(II)/Cu(I) electron transfer at a biomimetic Cu centre.

    Get PDF
    International audienceThe coordination properties of the biomimetic complex [Cu(TMPA)(H2O)](CF3SO3)2 (TMPA = tris(2-pyridylmethyl)amine) have been investigated by electrochemistry combined with UV-Vis and EPR spectroscopy in different non-coordinating media including imidazolium-based room-temperature ionic liquids, for different water contents. The solid-state X-ray diffraction analysis of the complex shows that the cupric centre lies in a N4O coordination environment with a nearly perfect trigonal bipyramidal geometry (TBP), the water ligand being axially coordinated to Cu(II). In solution, the coordination geometry of the complex remains TBP in all media. Neither the triflate ion nor the anions of the ionic liquids were found to coordinate the copper centre. Cyclic voltammetry in all media shows that the decoordination of the water molecule occurs upon monoelectronic reduction of the Cu(II) complex. Back-coordination of the water ligand at the cuprous state can be detected by increasing the water content and/or decreasing the timescale of the experiment. Numerical simulations of the voltammograms allow the determination of kinetics and thermodynamics for the water association-dissociation mechanism. The resulting data suggest that (i) the binding/unbinding of water at the Cu(I) redox state is relatively slow and equilibrated in all media, and (ii) the binding of water at Cu(I) is somewhat faster in the ionic liquids than in the non-coordinating solvents, while the decoordination process is weakly sensitive to the nature of the solvents. These results suggest that ionic liquids favour water exchange without interfering with the coordination sphere of the metal centre. This makes them promising media for studying host-guest reactions with biomimetic complexes

    Bidimensional spectroelectrochemistry: application of a new device in the study of a o-vanillin-copper(II) complex

    Get PDF
    A new bidimensional spectroelectrochemistry setup for UV-Vis absorption measurements has been developed. The new device has been used to follow electrochemical reactions using two different arrangements: 1) a near-normal configuration that supplies information about the processes taking place both on the electrode surface and in the solution adjacent to it, and 2) a long-optical-pathway configuration based on a mobile slit that controls the position of a light beam passing parallel and adjacent to the electrode surface providing information only about the processes taking place in solution during the electrochemical reaction. The new setup has been validated using o-tolidine, a typical reference system for spectroelectrochemistry. The electrochemical mechanism of oxidation/reduction of Cu(o-Va)2(H2O)2 complex (o-Va = o-Vanillin = 2-hydroxy-3-methoxybenzaldehyde) has been studied using bidimensional UV-Vis absorption spectroelectrochemistry. This Cu(II) complex exhibits antimutagenic, anticarcinogenic and superoxide dismutase mimic properties.Junta de Castilla y LeĂłn (BU033U16), and Ministerio de EconomĂ­a y Competitividad (CTQ2014-55583-R, CTQ2014-61914-EXP, CTQ2015-71955-REDT)CONICET, UNLP, Junta de Castilla y LeĂłn (BU033U16), and Ministerio de EconomĂ­a y Competitividad (CTQ2014-55583-R, CTQ2014-61914-EXP, CTQ2015-71955-REDT

    Fluorescence devices for the detection of dental caries

    Get PDF
    BACKGROUND: Caries is one of the most prevalent and preventable conditions worldwide. If identified early enough then non‐invasive techniques can be applied, and therefore this review focusses on early caries involving the enamel surface of the tooth. The cornerstone of caries detection is a visual and tactile dental examination, however alternative methods of detection are available, and these include fluorescence‐based devices. There are three categories of fluorescence‐based device each primarily defined by the different wavelengths they exploit; we have labelled these groups as red, blue, and green fluorescence. These devices could support the visual examination for the detection and diagnosis of caries at an early stage of decay. OBJECTIVES: Our primary objectives were to estimate the diagnostic test accuracy of fluorescence‐based devices for the detection and diagnosis of enamel caries in children or adults. We planned to investigate the following potential sources of heterogeneity: tooth surface (occlusal, proximal, smooth surface or adjacent to a restoration); single point measurement devices versus imaging or surface assessment devices; and the prevalence of more severe disease in each study sample, at the level of caries into dentine. SEARCH METHODS: Cochrane Oral Health's Information Specialist undertook a search of the following databases: MEDLINE Ovid (1946 to 30 May 2019); Embase Ovid (1980 to 30 May 2019); US National Institutes of Health Ongoing Trials Register (ClinicalTrials.gov, to 30 May 2019); and the World Health Organization International Clinical Trials Registry Platform (to 30 May 2019). We studied reference lists as well as published systematic review articles. SELECTION CRITERIA: We included diagnostic accuracy study designs that compared a fluorescence‐based device with a reference standard. This included prospective studies that evaluated the diagnostic accuracy of single index tests and studies that directly compared two or more index tests. Studies that explicitly recruited participants with caries into dentine or frank cavitation were excluded. DATA COLLECTION AND ANALYSIS: Two review authors extracted data independently using a piloted study data extraction form based on the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS‐2). Sensitivity and specificity with 95% confidence intervals (CIs) were reported for each study. This information has been displayed as coupled forest plots and summary receiver operating characteristic (SROC) plots, displaying the sensitivity‐specificity points for each study. We estimated diagnostic accuracy using hierarchical summary receiver operating characteristic (HSROC) methods. We reported sensitivities at fixed values of specificity (median 0.78, upper quartile 0.90). MAIN RESULTS: We included a total of 133 studies, 55 did not report data in the 2 x 2 format and could not be included in the meta‐analysis. 79 studies which provided 114 datasets and evaluated 21,283 tooth surfaces were included in the meta‐analysis. There was a high risk of bias for the participant selection domain. The index test, reference standard, and flow and timing domains all showed a high proportion of studies to be at low risk of bias. Concerns regarding the applicability of the evidence were high or unclear for all domains, the highest proportion being seen in participant selection. Selective participant recruitment, poorly defined diagnostic thresholds, and in vitro studies being non‐generalisable to the clinical scenario of a routine dental examination were the main reasons for these findings. The dominance of in vitro studies also means that the information on how the results of these devices are used to support diagnosis, as opposed to pure detection, was extremely limited. There was substantial variability in the results which could not be explained by the different devices or dentition or other sources of heterogeneity that we investigated. The diagnostic odds ratio (DOR) was 14.12 (95% CI 11.17 to 17.84). The estimated sensitivity, at a fixed median specificity of 0.78, was 0.70 (95% CI 0.64 to 0.75). In a hypothetical cohort of 1000 tooth sites or surfaces, with a prevalence of enamel caries of 57%, obtained from the included studies, the estimated sensitivity of 0.70 and specificity of 0.78 would result in 171 missed tooth sites or surfaces with enamel caries (false negatives) and 95 incorrectly classed as having early caries (false positives). We used meta‐regression to compare the accuracy of the different devices for red fluorescence (84 datasets, 14,514 tooth sites), blue fluorescence (21 datasets, 3429 tooth sites), and green fluorescence (9 datasets, 3340 tooth sites) devices. Initially, we allowed threshold, shape, and accuracy to vary according to device type by including covariates in the model. Allowing consistency of shape, removal of the covariates for accuracy had only a negligible effect (Chi(2) = 3.91, degrees of freedom (df) = 2, P = 0.14). Despite the relatively large volume of evidence we rated the certainty of the evidence as low, downgraded two levels in total, for risk of bias due to limitations in the design and conduct of the included studies, indirectness arising from the high number of in vitro studies, and inconsistency due to the substantial variability of results. AUTHORS' CONCLUSIONS: There is considerable variation in the performance of these fluorescence‐based devices that could not be explained by the different wavelengths of the devices assessed, participant, or study characteristics. Blue and green fluorescence‐based devices appeared to outperform red fluorescence‐based devices but this difference was not supported by the results of a formal statistical comparison. The evidence base was considerable, but we were only able to include 79 studies out of 133 in the meta‐analysis as estimates of sensitivity or specificity values or both could not be extracted or derived. In terms of applicability, any future studies should be carried out in a clinical setting, where difficulties of caries assessment within the oral cavity include plaque, staining, and restorations. Other considerations include the potential of fluorescence devices to be used in combination with other technologies and comparative diagnostic accuracy studies

    Stratégies avancées pour des systÚmes photovoltaïques ultra-performants

    Full text link
    The maximum efficiency limit attainable with a single-junction PV cell is ~ 33% according to the detailed balance formalism (also known as Shockley-Queisser model), which remains far from the Carnot limit, predicting a solar to electricity efficiency upper value of 93%. The large gap between both limits is due to intrinsic loss mechanisms, including the inefficient conversion of the solar spectrum and the large discrepancy between the solid angles of absorption and emission. To overcome these losses and get closer to the Carnot limit, three different strategies are considered in this thesis: concentrated multi-junction solarcells, the combination of solar concentration and angular confinement, and hybrid PV/CSP systems. Each strategy is inherently limited by several loss mechanisms that degrade their performances. The objective of this thesis is, hence, to better understand the extent to which these strategies are likely to be penalized by these losses, and to tailor the cell properties toward maximizing their efficiencies. To address these questions, a detailed-balance model of PV cell accounting for the main loss mechanisms was developed. A genetic-algorithm optimization tool was also implemented, aiming at exploring the parameter space and identifying the optimal operation conditions. We demonstrate the uttermost importance of tailoring the electronic properties of the materials used with both multi-junction solar cells undergoing significant series resistance losses, and PV cells operating at temperature levels exceeding ambient temperature. We also investigate the extent to which series resistances losses and non-radiative recombination are likely to affect the ability of PV cells simultaneously submitted to concentrated sunlight and angular restriction of the light emitted by band-to-band recombination.La limite thĂ©orique de rendement des cellules photovoltaĂŻques simple-jonction est de l’ordre de 33% d’aprĂšs le modĂšle de Shockley-Queisser, ce qui reste Ă©loignĂ© de la limite de Carnot, prĂ©disant une limite maximale de conversion Ă©nergie solaire → Ă©lectricitĂ© de 93%. L’écart important entre ces deux limites dĂ©coule des pertes intrinsĂšques, essentiellement liĂ©es Ă  la conversion inefficace du spectre solaire et Ă  la disparitĂ© entre les angles solides d’absorption et d’émission. Pour surmonter ces pertes et se rapprocher de la limite de Carnot, trois stratĂ©gies sont envisagĂ©es dans cette thĂšse : les cellules multi-jonction Ă concentration, la combinaison de la concentration et de la restriction angulaire et les systĂšmes hybrides PV/CSP. Chacune de ces stratĂ©gies est limitĂ©e par des mĂ©canismes qui dĂ©gradent leur performance.L’objectif de cette thĂšse est donc de comprendre dans quelle mesure les diffĂ©rents mĂ©canismes limitants sont susceptibles d’affecter les performances des diffĂ©rentes stratĂ©gies Ă©tudiĂ©es, et d’optimiser l’architecture des cellules dans le but d’accroitre leur efficacitĂ© de conversion. Dans ce but, un modĂšle dĂ©taillĂ© de cellule solaire tenant compte des principaux mĂ©canismes limitant a Ă©tĂ© dĂ©veloppĂ©. Un outil d’optimisation par algorithme gĂ©nĂ©tique a Ă©galement Ă©tĂ© mis au point, afin d’explorer l’espace des diffĂ©rents paramĂštres Ă©tudiĂ©s pour identifier les conditions d’opĂ©ration optimales. Nous dĂ©montrons l’importance majeure que revĂȘt l’adaptation des propriĂ©tĂ©s optoĂ©lectroniques des matĂ©riaux utilisĂ©s aux conditions opĂ©ratoires, que ce soit dans le cas des cellules solaires Ă  concentration endurant des pertes rĂ©sistives significatives, ou encore dans le cas de cellules solaires fonctionnant Ă  des niveaux de tempĂ©ratures trĂšs supĂ©rieurs Ă  l’ambiante. Enfin, nous avons dĂ©terminĂ© l’effet des principaux facteurs limitant que constituent les pertes rĂ©sistives et les recombinaisons non-radiatives sur les cellules solairessimultanĂ©ment soumises au flux solaire concentrĂ© et Ă  la restriction angulaire du rayonnement Ă©mis
    • 

    corecore