223 research outputs found
Fracture with loss of the proximal femur in a child. A case report.
An 8 year old child was involved in a road accident and sustained a large wound in the left groin; radiographs showed a fracture with loss of the proximal femur. After skeletal traction for 80 days, there was bony regeneration of the proximal femur. At 8 months she was able to walk without support and her left leg was 2 cm only shorter than the right
Femoral revision with the modular ZMR stem. Clinical and x-rays results at medium term follow-up
A retrospective review was conducted to evaluate the medium-term results of the ZMR modular revision taper stem. From March 1999 to December 2002, 65 consecutive hip revision surgeries were performed mostly for aseptic loosening. Femoral bone stock defects were classified according to AAOS\u2019s criteria and consisted mainly in type II and type III. A Wagner osteotomy was performed in 25 cases to remove primary implants that were cemented in 35 cases. Mean post-operative follow-up was 69 months (range, 36 to 91months). Clinical assessment at follow-up showed a significantly improved mean Harris Hip Score from 42 points preoperatively to 81 points postoperatively, while the x-ray examination did show a satisfactory distal integration of the stem in all cases and satisfactory reconstitution of the femoral bone stock in 47% of cases. The average subsidence of the stem at follow-up was under one millimeter. According to the data leg length discrepancy exceeding 15
millimeters caused significantly higher functional impairment and more pain
Lateral parapatellar approach in primary total knee arthroplasty of the valgus knee
Background Anatomic and pathological characteristics of the valgus knee deformity represent a challenging issue for the implant of a total knee arthroplasty. The surgical approach in such cases should allow a direct ad easy exposure of the joint, easy lateral soft tissue balancing and adequate patellar tracking. Materials and Methods Twenty-four total knee arthroplasties were implanted in valgus knees between January 2002 and September 2005. A mean preoperative valgus deformity of 18\ub0 was assessed on standing x-rays. Four posterior stabilized, eighteen posterior stabilized rotating platform prosthesis and two superstabilized prosthesis were implanted in 21 patients. The surgical approach has been in all cases a lateral parapatellectomy. Follow-up assessments were obtained for all patients at a mean 23 months. They consisted of a Knee Society Score and a Patellar Score evaluation, standing AP and lateral radiograms and skyline x-rays obtained at a flection of 45\ub0. Results A mean preoperative Knee Society Clinical Score of 32,7 points (range, -4 to 64 points) significantly improved at follow-up to an average 88,8 points (range, 57 to 99 points; p<0,05). The Knee Society Function Score significantly increased from a preoperative mean score of 32,7 points (range, -20 to 75 points) to an average followup score of 81,2 points (range, 30 to 100 points; p<0.05). The Patella Score revealed absence of anterior pain in all cases but one that reported severe pain. A satisfactory patello-femoral alignement of 4.7\ub0 (range, 1\ub0 to 10\ub0) was obtained at last follow-up x-rays. One intraoperative condilar fracture occured and was treated with a single screw. Discussion The lateral approach of valgus knees led to satisfactory results in primary total knee arthroplasties in a percentage of cases comparable or superior to those presented in literature for different approaches. In addition, lateral release is performed as a part of the approach itself, allows preservation of the blood supplies of the extensor apparatus and an optimal patellar tracking in most cases. Conclusions In conclusion, the lateral approach for a primary total knee arthroplasty could be recommended in valgus knees affected by osteoarthritis because as it proved to be effective in achieving a satisfactory implant positioning and functional outcome while reporting minor complications
The relevance of hydroxyapatite and spongious titanium coatings in fixation of cementless stems. An experimental comparative study in rat femur employing histological and microangiographic techniques.
Pure titanium rods plasma-spray coated with hydroxyapatite (HA) or porous titanium (Ti) of controlled roughness were implanted bilaterally in the distal femur of Sprague-Dawley rats to compare the extent of bone growth on the two types of coating. The relevance of other factors, like mechanical stability and biological adaptation of the bone to the insertion of a foreign body implant, were investigated in femora which were over-reamed (absence of primary fit) or reamed without insertion of the rod. Continuous tetracycline labeling for the first 30 days and for the last 2 weeks in the 90-day group was performed; histological/histometric, fluorescence and microangiographic studies were carried out on serial sections of the implanted and control femora. In the group of stable implants, HA-coated rods showed 90% integration versus 53% with Ti-coated implants (P < 0.001); in over-reamed implants neither surface bone growth nor endosteal fixation occurred, and both types of rods were surrounded by a thick layer of connective tissue. The study documented early adhesion of osteoblasts and direct deposition of bone matrix on the substrate, while on spongious titanium osteogenesis was observed only in proximity to the surface. Remodeling of the reactive, primary bone to mature, lamellar bone took the form of a capsule surrounding the implants and radial bridges connecting the latter to the endosteal surface. The number, height and thickness of these bridges appeared to be the factors determining implant stability, rather than the extent of the bony capsule on the perimeter of the implant. Integration was a function not only of mechanical conditions and surface geometry, but also of the biological response of the whole bone to changes in the vascularization pattern. The reported phenomena can be seen more easily in experimental models involving small rodents because of their fast bone turnover and revascularization, but it is expected that they take place, even at a lower speed, in clinical situations like cementless stems of total hip replacement
Treatment of periprosthetic femoral fractures with distal fixation modular revision stems
Background Late periprosthetic fractures of the femur are the third most frequently reported cause of surgery after total hip artroplasty. Revision total hip artroplasty can be difficult, especially when poor bone stock is encountered. The aim of this study was to examine the results of late periprosthetic fractures complicated with primary implant loosening performed with distal fixation modular revision stem. Methods From November 1999 to May 2006, 16 late periprosthetic fractures were treated with distal-fixation, modular, straight stem. There were 13 females (82%) and 3 males (18%) whose mean age at surgery was 76.7 years (range, 48 to 95 years). Femoral revision surgery was performed with the Revitan (2 cases) and ZMR (14 cases) to get a stable distal primary fixation. X-rays were assessed accordingly to the Vancouver classification: there were 3 type B2 and 13 type B3 fractures. Mean post-operative follow-up was 52 months (range, 10 to 88 months). At the time of the last follow-up visit 4 patients already passed away, all of them for causes unrelated to the procedure. The clinical outcome was monitored with the Harris Hip Score, subjective VAS, pain and satisfaction evaluation. Standard AP and lateral x-rays of the hip were obtained at each follow-up visit. Leg-length discrepancy was also investigated as a factor possibly affecting outcome. Complications included one septic loosening that was treated with a two-stage revision. Results All the patients but one were finally able to walk and had minimal to no pain at all. A satisfactory functional outcome was achieved with an average 76 (range, 25 to 100) Harris Hip Scores points. The subjective pain and satisfaction scores were respectively 2.4 and 7.8 points. As far as radiograms are concerned, all the sixteen femur did show a good healing of the fracture, with no secondary stem subsidence. Discussion Generally, considering the severity of an event such as a periprosthetic late fracture in an elderly patient, results were satisfactory. The average Harris Hip Score and subjective satisfaction would have been even higher if one patient wouldn\u2019t have been so much disappointed because of her severe leg-length discrepancy, dependent on the acetabular side. From a surgical point of view, the employed devices proved to be handy in bridging the fracture with distal fixation while adequately stabilizing it. Conclusions According to the reported results, straight modular-revison stems provide an adequate treatment option of Vancouver type B3 and in selected cases of B2 type periprosthetic femoral fracture
Radiological evaluation of the metal-bone interface of a porous tantalum acetabular component
Introduction Porous tantalum presents a bone-matched elastic modulus and an high coefficient of friction on cancellous and cortical bone. Furthermore, its open-cell tantalum structure of repeating dodecahedrons, similar to cancellous bone, should be favourable for bone ingrowth. These physical and mechanical properties should increase primary fixation and potential osteointegration of acetabular cups and should decrease periacetabular stress shielding. The purpose of this study was to radiographically evaluate the evolution of the metal-bone interface of porous tantalum acetabular components.
Materials and Methods Serial radiographic evaluation of 41porous tantalum acetabular component has been performed in 40 patients. Twelve hips underwent total hip arthroplasty using a trabecular metal monoblock acetabular component and 29 hips using a trabecular metal modular acetabular system. All patients were clinically and radiographically evaluated at four, eight, 12, 24 weeks, 12 months and then annually. All cases were available for a minimum follow-up of two years (mean 35 months). On post-operative x-rays the metal-bone interface was investigated for areas in which the porous surface of the acetabular component was not in contact with bone. These gaps were measured and classified by
location according to DeLee and Charnley zones. Evolution of postoperative gaps, presence of lysis or periacetabular radiolucencies and component migration were assessed during follow-up.
Results On post-operative x-rays 36 components (88%) had a gap between the outer surface and the host bone but only in 12 cases (29%) gaps were larger then 1 mm. The gaps were mostly situated in the polar region (zone II) when compared with the peripheral zones and no one was bigger then 5 mm in width. At last follow-up 23 (64%) of the initial gaps were no longer radiographically evident, 10 (28%) had a favourable evolution and appeared reduced in dimension but still present and 3 (8%) didn\u2019t fill at all and were unchanged when compared with post-operative controls. There was no progression progression of any post-operative gap and no evidence of new periacetabular radiolucent lines or lysis. No acetabular implant showed evidence of migration or needed revision for loosening. At last follow up the mean Harris Hip Score was 95. There were no dislocation or other complications. Discussion Short term results with porous tantalum acetabular component are encouraging: the bridging of the interface gaps and the absence of periacetabular radiolucencies indicate good mechanical and osteoconductive properties. Further follow-up will be required to confirm these results in the long term
Acetabular revision surgery in the presence of severe bone loss: surgical technique and early results with modular porous tantalum augments and cups
Subject: In the presence of minimal acetabular bone loss most revision procedures can be done with the use of an uncemented hemispheric device with or without morselized allograft. The use of modular porous tantalum augments and cups has been recently introduced to address more severe bone deficiencies. The purpose of this study is to describe the surgical technique and early clinical results obtained with trabecular metal acetabular augments in cases of acetabular revision with severe bone loss.
Materials and Methods: Since November 2003 seven acetabular revisions have been done by means of TMT\uae augments and cups: the primary indication for acetabular revision was aseptic loosening in five patients and septic loosening in two patients. According to Paprosky classification the acetabular bone defects were classified as follows: 2B in two hips, 2C in one hip, 3A in two hips and 3B in three hips. In two cases it was the first surgical hip replacement procedure. Five cases were multiple revisions.
Results: At an average follow-up of 24 months no implant had evidence of loosening or migration. No dislocations occurred. Discussions and Conclusions: Augments provide mechanical support to hemispheric cups of various dimensions. This surgical technique avoids the use of structural allograft, helps to restore the center of hip rotation and increases contact area between the implant and the host bone for biological fixation. Longer follow-up is required to verify survival of these implants and potential mechanical and biologic complications related to use of this modular TMT\uae system
Squeezed light from a nanophotonic molecule
Delicate engineering of integrated nonlinear structures is required for developing scalable sources of non-classical light to be deployed in quantum information processing systems. In this work, we demonstrate a photonic molecule composed of two coupled microring resonators on an integrated nanophotonic chip, designed to generate strongly squeezed light uncontaminated by noise from unwanted parasitic nonlinear processes. By tuning the photonic molecule to selectively couple and thus hybridize only the modes involved in the unwanted processes, suppression of parasitic parametric fluorescence is accomplished. This strategy enables the use of microring resonators for the efficient generation of degenerate squeezed light: without it, simple single-resonator structures cannot avoid contamination from nonlinear noise without significantly compromising pump power efficiency. We use this device to generate 8(1) dB of broadband degenerate squeezed light on-chip, with 1.65(1) dB directly measured
Suppression of Parasitic Nonlinear Processes in Spontaneous Four-Wave Mixing with Linearly Uncoupled Resonators
We report on a signal-to-noise ratio characterizing the generation of identical photon pairs of more than 4 orders of magnitude in a ring resonator system. Parasitic noise, associated with single-pump spontaneous four-wave mixing, is essentially eliminated by employing a novel system design involving two resonators that are linearly uncoupled but nonlinearly coupled. This opens the way to a new class of integrated devices exploiting the unique properties of identical photon pairs in the same optical mode
- …