6 research outputs found
Interrater agreement for consensus definitions of delayed ischemic events after aneurysmal subarachnoid hemorrhage
Background: Thirty percent of patients with subarachnoid hemorrhage experience delayed cerebral ischemia or delayed ischemic neurologic decline (DIND). Variability in the definitions of delayed ischemia makes outcome studies difficult to compare. A recent consensus statement advocates standardized definitions for delayed ischemia in clinical trials of subarachnoid hemorrhage. We sought to evaluate the interrater agreement of these definitions. Methods: Based on consensus definitions, we assessed for: (1) delayed cerebral infarction, defined as radiographic cerebral infarction; (2) DIND type 1 (DIND1), defined as focal neurologic decline; and (3) DIND2, defined as a global decline in arousal. Five neurologists retrospectively reviewed electronic records of 58 patients with subarachnoid hemorrhage. Three reviewers had access to and reviewed neuroradiology imaging. We assessed interrater agreement using the Gwet kappa statistic. Results: Interrater agreement statistics were excellent (95.83%) for overall agreement on the presence or absence of any delayed ischemic event (DIND1, DIND2, or delayed cerebral infarction). Agreement was "moderate" for specifically identifying DIND1 (56.58%) and DIND2 (48.66%) events. We observed greater agreement for DIND1 when there was a significant focal motor decline of at least 1 point in the motor score. There was fair agreement (39.20%) for identifying delayed cerebral infarction; CT imaging was the predominant modality. Conclusions: Consensus definitions for delayed cerebral ischemia yielded near-perfect overall agreement and can thus be applied in future large-scale studies. However, a strict process of adjudication, explicit thresholds for determining focal neurologic decline, and MRI techniques that better discriminate edema from infarction seem critical for reproducibility of determination of specific outcome phenotypes, and will be important for successful clinical trials.SCOPUS: re.jinfo:eu-repo/semantics/publishe
Automation of Classical QEEG trending methods for early detection of delayed cerebral ischemia: More work to do
The purpose of this study is to evaluate automated implementations of continuous EEG monitoring-based detection of delayed cerebral ischemia based on methods used in classical retrospective studies. We studied 95 patients with either Fisher 3 or Hunt Hess 4 to 5 aneurysmal subarachnoid hemorrhage who were admitted to the Neurosciences ICU and underwent continuous EEG monitoring. We implemented several variations of two classical algorithms for automated detection of delayed cerebral ischemia based on decreases in alpha-delta ratio and relative alpha variability. Of 95 patients, 43 (45%) developed delayed cerebral ischemia. Our automated implementation of the classical alpha-delta ratio-based trending method resulted in a sensitivity and specificity (Se,Sp) of (80,27)%, compared with the values of (100,76)% reported in the classic study using similar methods in a nonautomated fashion. Our automated implementation of the classical relative alpha variability-based trending method yielded (Se,Sp) values of (65,43)%, compared with (100,46)% reported in the classic study using nonautomated analysis. Our findings suggest that improved methods to detect decreases in alpha-delta ratio and relative alpha variability are needed before an automated EEG-based early delayed cerebral ischemia detection system is ready for clinical use.SCOPUS: re.jinfo:eu-repo/semantics/publishe
Recommended from our members
Electroencephalogram in the intensive care unit: a focused look at acute brain injury
Over the past decades, electroencephalography (EEG) has become a widely applied and highly sophisticated brain monitoring tool in a variety of intensive care unit (ICU) settings. The most common indication for EEG monitoring currently is the management of refractory status epilepticus. In addition, a number of studies have associated frequent seizures, including nonconvulsive status epilepticus (NCSE), with worsening secondary brain injury and with worse outcomes. With the widespread utilization of EEG (spot and continuous EEG), rhythmic and periodic patterns that do not fulfill strict seizure criteria have been identified, epidemiologically quantified, and linked to pathophysiological events across a wide spectrum of critical and acute illnesses, including acute brain injury. Increasingly, EEG is not just qualitatively described, but also quantitatively analyzed together with other modalities to generate innovative measurements with possible clinical relevance. In this review, we discuss the current knowledge and emerging applications of EEG in the ICU, including seizure detection, ischemia monitoring, detection of cortical spreading depolarizations, assessment of consciousness and prognostication. We also review some technical aspects and challenges of using EEG in the ICU including the logistics of setting up ICU EEG monitoring in resource-limited settings.SCOPUS: re.jinfo:eu-repo/semantics/publishe
Assessment of the Validity of the 2HELPS2B Score for Inpatient Seizure Risk Prediction
Importance: Seizure risk stratification is needed to boost inpatient seizure detection and to improve continuous electroencephalogram (cEEG) cost-effectiveness. 2HELPS2B can address this need but requires validation. Objective: To use an independent cohort to validate the 2HELPS2B score and develop a practical guide for its use. Design, Setting, and Participants: This multicenter retrospective medical record review analyzed clinical and EEG data from patients 18 years or older with a clinical indication for cEEG and an EEG duration of 12 hours or longer who were receiving consecutive cEEG at 6 centers from January 2012 to January 2019. 2HELPS2B was evaluated with the validation cohort using the mean calibration error (CAL), a measure of the difference between prediction and actual results. A Kaplan-Meier survival analysis was used to determine the duration of EEG monitoring to achieve a seizure risk of less than 5% based on the 2HELPS2B score calculated on first- hour (screening) EEG. Participants undergoing elective epilepsy monitoring and those who had experienced cardiac arrest were excluded. No participants who met the inclusion criteria were excluded. Main Outcomes and Measures: The main outcome was a CAL error of less than 5% in the validation cohort. Results: The study included 2111 participants (median age, 51 years; 1113 men [52.7%]; median EEG duration, 48 hours) and the primary outcome was met with a validation cohort CAL error of 4.0% compared with a CAL of 2.7% in the foundational cohort (P =.13). For the 2HELPS2B score calculated on only the first hour of EEG in those without seizures during that hour, the CAL error remained at less than 5.0% at 4.2% and allowed for stratifying patients into low- (2HELPS2B = 0; 25%) groups. Each of the categories had an associated minimum recommended duration of EEG monitoring to achieve at least a less than 5% risk of seizures, a 2HELPS2B score of 0 at 1-hour screening EEG, a 2HELPS2B score of 1 at 12 hours, and a 2HELPS2B score of 2 or greater at 24 hours. Conclusions and Relevance: In this study, 2HELPS2B was validated as a clinical tool to aid in seizure detection, clinical communication, and cEEG use in hospitalized patients. In patients without prior clinical seizures, a screening 1-hour EEG that showed no epileptiform findings was an adequate screen. In patients with any highly epileptiform EEG patterns during the first hour of EEG (ie, a 2HELPS2B score of ≥2), at least 24 hours of recording is recommended.SCOPUS: cp.jinfo:eu-repo/semantics/publishe
Electroencephalographic Abnormalities are Common in COVID-19 and are Associated with Outcomes
Objective: The aim was to determine the prevalence and risk factors for electrographic seizures and other electroencephalographic (EEG) patterns in patients with Coronavirus disease 2019 (COVID-19) undergoing clinically indicated continuous electroencephalogram (cEEG) monitoring and to assess whether EEG findings are associated with outcomes. Methods: We identified 197 patients with COVID-19 referred for cEEG at 9 participating centers. Medical records and EEG reports were reviewed retrospectively to determine the incidence of and clinical risk factors for seizures and other epileptiform patterns. Multivariate Cox proportional hazards analysis assessed the relationship between EEG patterns and clinical outcomes. Results: Electrographic seizures were detected in 19 (9.6%) patients, including nonconvulsive status epilepticus (NCSE) in 11 (5.6%). Epileptiform abnormalities (either ictal or interictal) were present in 96 (48.7%). Preceding clinical seizures during hospitalization were associated with both electrographic seizures (36.4% in those with vs 8.1% in those without prior clinical seizures, odds ratio [OR] 6.51, p = 0.01) and NCSE (27.3% vs 4.3%, OR 8.34, p = 0.01). A pre-existing intracranial lesion on neuroimaging was associated with NCSE (14.3% vs 3.7%; OR 4.33, p = 0.02). In multivariate analysis of outcomes, electrographic seizures were an independent predictor of in-hospital mortality (hazard ratio [HR] 4.07 [1.44–11.51], p < 0.01). In competing risks analysis, hospital length of stay increased in the presence of NCSE (30 day proportion discharged with vs without NCSE: HR 0.21 [0.03–0.33] vs 0.43 [0.36–0.49]). Interpretation: This multicenter retrospective cohort study demonstrates that seizures and other epileptiform abnormalities are common in patients with COVID-19 undergoing clinically indicated cEEG and are associated with adverse clinical outcomes. ANN NEUROL 2021;89:872–883.SCOPUS: ar.jinfo:eu-repo/semantics/publishe
Deep active learning for Interictal Ictal Injury Continuum EEG patterns
Objectives: Seizures and seizure-like electroencephalography (EEG) patterns, collectively referred to as “ictal interictal injury continuum” (IIIC) patterns, are commonly encountered in critically ill patients. Automated detection is important for patient care and to enable research. However, training accurate detectors requires a large labeled dataset. Active Learning (AL) may help select informative examples to label, but the optimal AL approach remains unclear. Methods: We assembled >200,000 h of EEG from 1,454 hospitalized patients. From these, we collected 9,808 labeled and 120,000 unlabeled 10-second EEG segments. Labels included 6 IIIC patterns. In each AL iteration, a Dense-Net Convolutional Neural Network (CNN) learned vector representations for EEG segments using available labels, which were used to create a 2D embedding map. Nearest-neighbor label spreading within the embedding map was used to create additional pseudo-labeled data. A second Dense-Net was trained using real- and pseudo-labels. We evaluated several strategies for selecting candidate points for experts to label next. Finally, we compared two methods for class balancing within queries: standard balanced-based querying (SBBQ), and high confidence spread-based balanced querying (HCSBBQ). Results: Our results show: 1) Label spreading increased convergence speed for AL. 2) All query criteria produced similar results to random sampling. 3) HCSBBQ query balancing performed best. Using label spreading and HCSBBQ query balancing, we were able to train models approaching expert-level performance across all pattern categories after obtaining ∼7000 expert labels. Conclusion: Our results provide guidance regarding the use of AL to efficiently label large EEG datasets in critically ill patients.SCOPUS: ar.jinfo:eu-repo/semantics/publishe