788 research outputs found
Performance of the Micromegas detector in the CAST experiment
The gaseous Micromegas detector designed for the CERN Axion search experiment
CAST, operated smoothly during Phase-I, which included the 2003 and 2004
running periods. It exhibited linear response in the energy range of interest
(1-10keV), good spatial sensitivity and energy resolution (15-19% FWHM at
5.9keV)as well as remarkable stability. The detector's upgrade for the 2004
run, supported by the development of advanced offline analysis tools, improved
the background rejection capability, leading to an average rate 5x10^-5
counts/sec/cm^2/keV with 94% cut efficiency. Also, the origin of the detected
background was studied with a Monte Carlo simulation, using the GEANT4 package.Comment: Prepared for PSD7: The Seventh International Conference on Position
Sensitive Detectors, Liverpool, United Kingdom, 12-16 Sep. 200
A low background Micromegas detector for the CAST experiment
A low background Micromegas detector has been operating on the CAST
experiment at CERN for the search of solar axions during the first phase of the
experiment (2002-2004). The detector operated efficiently and achieved a very
low level of background rejection ( counts
keVcms) thanks to its good spatial and energy resolution
as well as the low radioactivity materials used in the construction of the
detector. For the second phase of the experiment (2005-2007), the detector will
be upgraded by adding a shielding and including focusing optics. These
improvements should allow for a background rejection better than two orders of
magnitude.Comment: 6 pages, 3 figures To appear on the proceedings of the 9th ICATPP
Conference on AStroparticle, Particle, Space Physics, Detectors and Medical
Physics Application
The Micromegas detector of the CAST experiment
A low background Micromegas detector has been operating in the CAST
experiment at CERN for the search of solar axions during the first phase of the
experiment (2002-2004). The detector, made out of low radioactivity materials,
operated efficiently and achieved a very low level of background rejection (5 x
10^-5 counts/keV/cm^2/s) without shielding.Comment: 13 pages, 12 figures and images, submitted to New Journal o
Designing a multifaceted quality improvement intervention in primary care in a country where general practice is seeking recognition: the case of Cyprus
<p>Abstract</p> <p>Background</p> <p>Quality Improvement Interventions require significant financial investments, and therefore demand careful consideration in their design in order to maximize potential benefits. In this correspondence we present the methodological approach of a multifaceted quality improvement intervention aiming to improve quality of care in primary care, properly tailored for a country such as Cyprus where general practice is currently seeking recognition.</p> <p>Methods</p> <p>Our methodological approach was focused on the design of an open label, community-based intervention controlled trial using all patients from two urban and two rural public primary care centers diagnosed with hypertension and type II diabetes mellitus. The design of our intervention was grounded on a strong theoretical framework that included the Unified Theory of Acceptance and Use of Technology, and the Chronic Care Model, which synthesize evidence-based system changes in accordance with the Theory of Planned Behavior and the Theory of Reasoned Action. The primary outcome measure was improvement in the quality of care for two chronic diseases evaluated through specific clinical indicators, as well as the patient satisfaction assessed by the EUROPEP questionnaire and additional personal interviews.</p> <p>Results</p> <p>We designed a multifaceted quality improvement intervention model, supported by a varying degree of scientific evidence, tailored to local needs and specific country characteristics. Overall, the main components of the intervention were the development and adoption of an electronic medical record and the introduction of clinical guidelines for the management of the targeted chronic diseases facilitated by the necessary model of organizational changes.</p> <p>Conclusion</p> <p>Health planners and policy makers need to be aware of the potential use of certain theoretical models and applied methodology as well as inexpensive tools that may be suitably tailored to the local needs, in order to effectively design quality improvement interventions in primary care settings.</p
First results from the CERN Axion Solar Telescope (CAST)
Hypothetical axion-like particles with a two-photon interaction would be
produced in the Sun by the Primakoff process. In a laboratory magnetic field
(``axion helioscope'') they would be transformed into X-rays with energies of a
few keV. Using a decommissioned LHC test magnet, CAST has been running for
about 6 months during 2003. The first results from the analysis of these data
are presented here. No signal above background was observed, implying an upper
limit to the axion-photon coupling < 1.16 10^{-10} GeV^-1 at 95% CL for m_a
<~0.02 eV. This limit is comparable to the limit from stellar energy-loss
arguments and considerably more restrictive than any previous experiment in
this axion mass range.Comment: 4 pages, accepted by PRL. Final version after the referees comment
Achievement of treatment goals for primary prevention of cardiovascular disease in clinical practice across Europe: the EURIKA study
Aims: Most studies on the primary prevention of cardiovascular disease (CVD) have been limited to patients at high CVD risk. We assessed the achievement of treatment goals for CVD risk factors among patients with a substantial variation in CVD risk.
Methods and results: This study was conducted with 7641 outpatients aged â„50 years, free of clinical CVD and with at least one major CVD risk factor, selected from 12 European countries in 2009. Risk factor definition and treatment goals were based on the 2007 European guidelines on CVD prevention. Cholesterol fractions and glycated haemoglobin (HbA1c) were measured in a central laboratory. Cardiovascular disease risk was estimated with the SCORE equation. Patients' mean age was 63 years (48% men), and 40.1% had a high CVD risk. Among treated hypertensives (94.2%), only 38.8% achieved the blood pressure target of <140/90 mmHg [between-country range (BCR): 32.1â47.5%]. Among treated dyslipidaemic patients (74.4%), 41.2% attained both the total- and LDL-cholesterol target of <5 and <3 mmol/L, respectively (BCR: 24.3â68.4%). Among treated type 2 diabetic patients (87.2%), 36.7% achieved the <6.5% HbA1c target (BCR: 23.4â48.4%). Among obese patients on non-pharmacological treatment (92.2%), 24.7% reached the body mass index target of <30 kg/m2 (BCR: 12.7â37.1%). About one-third of controlled patients on treatment were still at high remaining CVD risk. Although most patients were advised to reduce excess weight and to follow a low-calorie diet, less than half received written recommendations.
Conclusions: In Europe, a large proportion of patients in primary prevention have CVD risk factors that remain uncontrolled, and lifestyle counselling is not well implemented; moreover, there is substantial between-country variation, which indicates additional room for improvement. Raised residual CVD risk is relatively frequent among patients despite control of their primary risk factors and should be addressed
Search for the glueball candidates f0(1500) and fJ(1710) in gamma gamma collisions
Data taken with the ALEPH detector at LEP1 have been used to search for gamma
gamma production of the glueball candidates f0(1500) and fJ(1710) via their
decay to pi+pi-. No signal is observed and upper limits to the product of gamma
gamma width and pi+pi- branching ratio of the f0(1500) and the fJ(1710) have
been measured to be Gamma_(gamma gamma -> f0(1500)). BR(f0(1500)->pi+pi-) <
0.31 keV and Gamma_(gamma gamma -> fJ(1710)). BR(fJ(1710)->pi+pi-) < 0.55 keV
at 95% confidence level.Comment: 10 pages, 3 figure
Search for supersymmetry with a dominant R-parity violating LQDbar couplings in e+e- collisions at centre-of-mass energies of 130GeV to 172 GeV
A search for pair-production of supersymmetric particles under the assumption
that R-parity is violated via a dominant LQDbar coupling has been performed
using the data collected by ALEPH at centre-of-mass energies of 130-172 GeV.
The observed candidate events in the data are in agreement with the Standard
Model expectation. This result is translated into lower limits on the masses of
charginos, neutralinos, sleptons, sneutrinos and squarks. For instance, for
m_0=500 GeV/c^2 and tan(beta)=sqrt(2) charginos with masses smaller than 81
GeV/c^2 and neutralinos with masses smaller than 29 GeV/c^2 are excluded at the
95% confidence level for any generation structure of the LQDbar coupling.Comment: 32 pages, 30 figure
Search for CP Violation in the Decay Z -> b (b bar) g
About three million hadronic decays of the Z collected by ALEPH in the years
1991-1994 are used to search for anomalous CP violation beyond the Standard
Model in the decay Z -> b \bar{b} g. The study is performed by analyzing
angular correlations between the two quarks and the gluon in three-jet events
and by measuring the differential two-jet rate. No signal of CP violation is
found. For the combinations of anomalous CP violating couplings, and , limits of \hat{h}_b < 0.59h^{\ast}_{b} < 3.02$ are given at 95\% CL.Comment: 8 pages, 1 postscript figure, uses here.sty, epsfig.st
- âŠ