263 research outputs found

    Semisolid processing characteristics of AM series Mg alloys by rheo-diecasting

    Get PDF
    The official published version of this Article can be found at the link below - Copyright @ 2006 ASM InternationalAn investigation has been made into the solidification behavior and microstructural evolution of AM50, AM70, and AM90 alloys during rheo-diecasting, their processibility, and the resulting mechanical properties. It was found that solidification of AM series alloys under intensive melt shearing in the unique twin-screw slurry maker during rheo-diecasting gave rise to numerous spheroidal primary magnesium (Mg) particles that were uniformly present in the microstructure. As a result, the network of the beta-Mg17Al12 phase was consistently interrupted by these spheroidal and ductile particles. Such a microstructure reduced the obstacle of deformation and the harmfulness of the beta-Mg17Al12 network on ductility, and therefore improved the ductility of rheo-diecast AM alloys. It was shown that, even with 9 wt pct Al, the elongation of rheo-diecast AM90 still achieved (9 +/- 1.2) pct. Rheodiecasting thus provides an attractive processing route for upgrading the alloy specification of AM series alloys by increasing the aluminum (Al) content while ensuring ductility. Assessment of the processibility of AM series alloys for semisolid processing showed that high Al content AM series alloys are more suitable for rheo-diecasting than low Al content alloys, because of the lower sensitivity of solid fraction to temperature, the lower liquidus temperature, and the smaller interval between the semisolid processing temperature and the complete solidification temperature.This work is supported by the EPSR

    Continuous twin screw rheo-extrusion of an AZ91D magnesium alloy

    Get PDF
    © The Minerals, Metals & Materials Society and ASM International 2012The twin screw rheo-extrusion (TSRE) is designed to take advantage of the nondendritc microstructure and thixotropic characterization of semisolid-metal slurries and produce simple metal profiles directly from melts. The extrusion equipment consists of a rotor-stator high shear slurry maker, a twin screw extruder, and a die assembly. The process is continuous and has a potential for significantly saving energy, manufacturing cost, and enhancing efficiency. The present investigation was carried out to study the process performance for processing rods of an AZ91D magnesium alloy and the microstructure evolution during processing. The semisolid slurry prepared by the process was characterized by uniformly distributed nondendritic granular primary phase particles. AZ91D rods with uniform and fine microstructures and moderate mechanical properties were produced. For the given slurry making parameters, decreasing extrusion temperature was found to improve microstructures and properties. The mechanisms of particle granulation and refinement and the effect of processing parameters on process performance and thermal management are discussed. © 2012 The Minerals, Metals & Materials Society and ASM International.EPSRC (UK) and Rautomead Lt

    Growth of the deep water rose shrimp Parapenaeus longirostris in Mauritanian waters (NW Africa)

    Get PDF
    The deep water rose shrimp Parapenaeus longirostris is the main target species of a Spanish fleet of shrimp bottom trawlers operating in the Mauritanian EEZ. The life history of this species is well known in north eastern Atlantic and Mediterranean waters, while the information is quite limited for the eastern central Atlantic. Biological samplings of the species were conducted by scientific observers onboard this fleet, from catches obtained during 17 fishing trips performed between March 2014 and June 2019. The carapace lengths (CL) of 91662 specimens (54% females and 46% males) were grouped in 33 monthly length frequency distributions. For the study of the length–age relationship, the Von Bertalanffy Growth Function (VBGF) was fit to the monthly length distributions by using the ELEFAN I routine followed by separating the frequency histograms into normal components through the Bhattacharya’s method and the NORMSEP routine. These analyses were carried out separately for males, females, and combined sexes, using the FISAT II automatic calculation program. CL of females and males ranged from 11.6 to 39.2 mm and 10.5 to 30.5 mm, respectively. Three and five modal components (annual cohorts) were identified for females and males, respectively. The growth function estimated parameters were CL∞=41.74, k=0.51 for combined sexes, CL∞= 41.67, k= 0.51 for females and CL∞= 32.24, k=0.84 for males. Estimated growth performance indices were around 2.95 for combined sexes, females and males. The estimated parameters may be used as input to test length-based methodologies for the assessment of this data-limited stock, for which only production models have been used so far

    Compressive Sensing of Signals Generated in Plastic Scintillators in a Novel J-PET Instrument

    Full text link
    The J-PET scanner, which allows for single bed imaging of the whole human body, is currently under development at the Jagiellonian University. The dis- cussed detector offers improvement of the Time of Flight (TOF) resolution due to the use of fast plastic scintillators and dedicated electronics allowing for sam- pling in the voltage domain of signals with durations of few nanoseconds. In this paper we show that recovery of the whole signal, based on only a few samples, is possible. In order to do that, we incorporate the training signals into the Tikhonov regularization framework and we perform the Principal Component Analysis decomposition, which is well known for its compaction properties. The method yields a simple closed form analytical solution that does not require iter- ative processing. Moreover, from the Bayes theory the properties of regularized solution, especially its covariance matrix, may be easily derived. This is the key to introduce and prove the formula for calculations of the signal recovery error. In this paper we show that an average recovery error is approximately inversely proportional to the number of acquired samples

    Application of the Compress Sensing Theory for Improvement of the TOF Resolution in a Novel J-PET Instrument

    Get PDF
    Nowadays, in Positron Emission Tomography (PET) systems, a Time of Flight information is used to improve the image reconstruction process. In Time of Flight PET (TOF-PET), fast detectors are able to measure the difference in the arrival time of the two gamma rays, with the precision enabling to shorten significantly a range along the line-of-response (LOR) where the annihilation occurred. In the new concept, called J-PET scanner, gamma rays are detected in plastic scintillators. In a single strip of J-PET system, time values are obtained by probing signals in the amplitude domain. Owing to Compress Sensing theory, information about the shape and amplitude of the signals is recovered. In this paper we demonstrate that based on the acquired signals parameters, a better signal normalization may be provided in order to improve the TOF resolution. The procedure was tested using large sample of data registered by a dedicated detection setup enabling sampling of signals with 50 ps intervals. Experimental setup provided irradiation of a chosen position in the plastic scintillator strip with annihilation gamma quanta

    Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography

    Full text link
    Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals and an example of an application of the method for a single module with a 30 cm long plastic strip, read out on both ends by Hamamatsu R4998 photomultipliers. The sampling scheme to generate a vector with samples of a PET event waveform with respect to four user-defined amplitudes is introduced. The experimental setup provides irradiation of a chosen position in the plastic scintillator strip with an annihilation gamma quanta of energy 511~keV. The statistical test for a multivariate normal (MVN) distribution of measured vectors at a given position is developed, and it is shown that signals sampled at four thresholds in a voltage domain are approximately normally distributed variables. With the presented method of a vector analysis made out of waveform samples acquired with four thresholds, we obtain a spatial resolution of about 1 cm and a timing resolution of about 80 p

    Study of the 3He-eta system in d-p collisions at COSY-11

    Full text link
    We present preliminary results from dp --> 3He X (X=pi0,eta) measurements near the eta production threshold. The data were taken during a slow ramping of the COSY internal deuteron beam scattered on a proton target. The 3He ejectiles were registered with the COSY-11 detection setup. The ongoing data analysis should deliver high precision data for the dp --> 3He eta total and differential cross sections for the excess energies in the range from threshold up to 9 MeV. The preliminary excitation function for the reaction dp --> 3He pi0 does not show any structure which could originate from the decay of 3He-eta bound state. We present also a threshold excitation curve for the dp --> 3He X channel. Contrary to corresponding results from SATURNE we see no cusp in the vicinity of the eta threshold.Comment: 8 pages; 5 figures; Talk at Eta05 Workshop on Production and Decay of eta and eta-prime Mesons, Cracow, Poland, 15-18 Sep 2005; Acta Phys. Slovaca, in prin
    corecore