2 research outputs found

    Incidence of esophageal injury after pulmonary vein isolation in patients with a low body mass index and esophageal temperature monitoring at a 39 °C setting

    No full text
    Background: Esophageal injury following catheter ablation of atrial fibrillation (AF) is reported to occur in 35% of patients. Even with a low energy setting (20–25 W), lesions develop in 10% of patients. Body mass index (BMI) has been reported to be a predictor of esophageal injury, indicating that patients with a low BMI (<24.9 kg/m2) are at a higher risk. We hypothesized that catheter ablation with a lower energy setting of 20 W controlled by esophageal temperature monitoring (ETM) at 39 °C could prevent esophageal injury even in patients with a BMI <24.9 kg/m2. Methods: Twenty patients with AF were included (age, 63±8 years; BMI, 22.9±1.3 kg/m2, left atrium diameter, 44±11 mm). If the esophageal temperature probe registered a temperature of >39 °C, radiofrequency (RF) application was stopped immediately. RF application could be performed in a “point by point” manner for a maximum of 20 s. Endoscopy was performed 1–5 days after ablation. Results: Esophageal mucosal injury was not observed in any patient in the study. Conclusions: Catheter ablation using ETM reduced the incidence of esophageal injuries, even in patients with a low BMI

    Visualizing radiofrequency lesions using delayed-enhancement magnetic resonance imaging in patients with atrial fibrillation: A modification of the method used by the University of Utah group

    Get PDF
    Background: Atrial tissue fibrosis has previously been identified using delayed-enhancement MRI (DE-MRI) in patients with atrial fibrillation (AF). Although the clinical importance of DE-MRI is well recognized, the visualization of atrial fibrosis and radiofrequency (RF) lesions has still not been achieved in Japan, primarily because of the differences in contrast agents, volume-rendering tools, and technical experience. The objective of this study was to visualize RF lesions by using commercially available tools. Methods: DE-MRI was performed in 15 patients who had undergone AF ablation (age, 59±4 years, left atrium diameter, 40±2 mm). Specific parameters for MR scanning obtained from previous reports were modified. Results: Of the 15 images, the images of three patients were uninterpretable owing to low image quality. RF lesions could be visualized in 8 (67%) of the 12 patients. Conclusions: In the current study, we successfully demonstrated that RF lesions could be visualized in Japanese patients using DE-MRI, although only commercially available tools were used
    corecore