157 research outputs found

    Demonstration of Hepatitis C Virus RNA with In Situ

    Get PDF
    Background. In situ hybridization (ISH) with high sensitivity has been requested to demonstrate hepatitis C virus (HCV) RNA in formalin-fixed, paraffin-embedded (FFPE) sections of the liver. Methods. ISH employing a locked-nucleic-acid- (LNA-)modified oligonucleotide probe and biotin-free catalyzed signal amplification system (CSAII) was applied to HCV-RNA detection in the liver tissue. Nested reverse-transcription polymerase chain reaction (RT-PCR) was performed for HCV genotyping using total RNA extracted from FFPE sections. The target tissues included FFPE tissue sections of humanized livers in HCV-infected chimeric mice (HCV genotypes 1a, 1b, and 2a and noninfected) and of needle-biopsied livers from HCV-infected patients. Results. HCV-RNA was demonstrated with the ISH technique in HCV-infected liver tissues from both chimeric mice and 9 (82%) of 11 patients with HCV infection. The HCV signals were sensitive to RNase. Nested RT-PCR confirmed the genotype in 8 (73%) of 11 livers (type 1b: 6 lesions and type 2a: 2 lesions). HCV-RNA was not identified in chronic hepatitis B lesions, fatty liver, autoimmune hepatitis, and hepatocellular carcinoma. Conclusion. ISH using the LNA-modified oligonucleotide probe and CSAII was applicable to detecting HCV-RNA in routinely prepared FFPE liver specimens

    Prognostic Impact of Baseline Hemoglobin Levels on Long-Term Thrombotic and Bleeding Events After Percutaneous Coronary Interventions

    Get PDF
    Background: Association of baseline hemoglobin levels with long-term adverse events after percutaneous coronary interventions has not been yet thoroughly defined. We aimed to assess the clinical impact of baseline hemoglobin on long-term ischemic and bleeding risk after percutaneous coronary intervention. Methods and Results: Using the pooled individual patient-level data from the 3 percutaneous coronary intervention studies, we categorized 19 288 patients into 4 groups: high-normal hemoglobin (≥14.0 g/dL; n=7555), low-normal hemoglobin (13.0-13.9 g/dL in men and 12.0-13.9 g/dL in women; n=5303), mild anemia (11.0-12.9 g/dL in men and 11.0-11.9 g/dL in women; n=4117), and moderate/severe anemia (<11.0 g/dL; n=2313). Median follow-up duration was 3 years. Low-normal hemoglobin, mild anemia, and moderate/severe anemia correlated with significant excess risk relative to high-normal hemoglobin for GUSTO (Global Utilization of Streptokinase and Tissue Plasminogen Activator for Occluded Arteries Trial) moderate/severe bleeding, with adjusted hazard ratios of 1.22 (95% CI, 1.04-1.44), 1.73 (95% CI, 1.47-2.04), and 2.31 (95% CI, 1.92-2.78), respectively. Moderate/severe anemia also correlated with significant excess risk relative to high-normal hemoglobin for the ischemic composite end point of myocardial infarction/ischemic stroke (adjusted hazard ratio, 1.33; 95% CI, 1.11-1.60), whereas low-normal hemoglobin and mild anemia did not. However, the excess risk of low-normal hemoglobin, mild anemia, and moderate/severe anemia relative to high-normal hemoglobin remained significant for ischemic stroke and for mortality. Conclusions: Decreasing baseline hemoglobin correlated with incrementally higher long-term risk for major bleeding, ischemic stroke, and mortality after percutaneous coronary intervention. Even within normal range, lower baseline hemoglobin level correlated with higher ischemic and bleeding risk

    SDSS J133401.39+331534.3: A New Subarcsecond Gravitationally Lensed Quasar

    Full text link
    The quasar SDSS J133401.39+331534.3 at z = 2.426 is found to be a two-image gravitationally lensed quasar with the image separation of 0.833. The object is first identified as a lensed quasar candidate in the Sloan Digital Sky Survey Quasar Lens Search, and then confirmed as a lensed system from follow-up observations at the Subaru and University of Hawaii 2.2-meter telescopes. We estimate the redshift of the lensing galaxy to be 0.557 based on absorption lines in the quasar spectra as well as the color of the galaxy. In particular, we observe the system with the Subaru Telescope AO188 adaptive optics with laser guide star, in order to derive accurate astrometry, which well demonstrates the usefulness of the laser guide star adaptive optics imaging for studying strong lens systems. Our mass modeling with improved astrometry implies that a nearby bright galaxy 4"\sim 4" apart from the lensing galaxy is likely to affect the lens potential.Comment: 24 pages, 6 figures. ApJ, in pres

    Newly Diagnosed Atrial Fibrillation in Acute Myocardial Infarction

    Get PDF
    [Background] It remains controversial whether long‐term clinical impact of newly diagnosed atrial fibrillation (AF) in the acute phase of acute myocardial infarction (AMI) is different from that of prior AF diagnosed before the onset of AMI. [Methods and Results] The current study population from the CREDO‐Kyoto AMI (Coronary Revascularization Demonstrating Outcome Study in Kyoto Acute Myocardial Infarction) Registry Wave‐2 consisted of 6228 patients with AMI who underwent percutaneous coronary intervention. The baseline characteristics and long‐term clinical outcomes were compared according to AF status (newly diagnosed AF: N=489 [7.9%], prior AF: N=589 [9.5%], and no AF: N=5150 [82.7%]). Median follow‐up duration was 5.5 years. Patients with newly diagnosed AF and prior AF had similar baseline characteristics with higher risk profile than those with no AF including older age and more comorbidities. The cumulative 5‐year incidence of all‐cause death was higher in newly diagnosed AF and prior AF than no AF (38.8%, 40.7%, and 18.7%, P<0.001). The adjusted hazard ratios (HRs) for mortality of newly diagnosed AF and prior AF relative to no AF remained significant with similar magnitude (HR, 1.31; 95% CI, 1.12–1.54; P<0.001, and HR, 1.32; 95% CI, 1.14–1.52; P<0.001, respectively). The cumulative 5‐year incidence of stroke decreased in the order of newly diagnosed AF, prior AF and no AF (15.5%, 12.9%, and 6.3%, respectively, P<0.001). The higher adjusted HRs of both newly diagnosed AF and prior AF relative to no AF were significant for stroke, with a greater risk of newly diagnosed AF than that of prior AF (HR, 2.05; 95% CI, 1.56–2.69; P<0.001, and HR, 1.33; 95% CI, 1.00–1.78; P=0.048, respectively). The higher stroke risk of newly diagnosed AF compared with prior AF was largely driven by the greater risk within 30 days. The higher adjusted HRs of newly diagnosed AF and prior AF relative to no AF were significant for heart failure hospitalization (HR, 1.73; 95% CI, 1.35–2.22; P<0.001, and HR, 2.23; 95% CI, 1.82–2.74; P<0.001, respectively) and major bleeding (HR, 1.46; 95% CI, 1.23–1.73; P<0.001, and HR, 1.36; 95% CI, 1.15–1.60; P<0.001, respectively). [Conclusions] Newly diagnosed AF in AMI had risks for mortality, heart failure hospitalization, and major bleeding higher than no AF, and comparable to prior AF. The risk of newly diagnosed AF for stroke might be higher than that of prior AF

    Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection

    Get PDF
    Backgrounds. With respect to the knife’s design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a regular diameter knife (Flush knife BT, diameter: 2.6 mm, length: 1800 mm). Methods. In laboratory and clinical research, electric power, knife insertion time, vacuum/suction amount with knife in the endoscopic channel, and water jet function were analyzed. We used a knife 2.0 mm long for BT-S and BT knives. Results. The BT-S showed faster mean knife insertion time (sec) and better vacuum amount (ml/min) compared to the BT (insertion time: 16.7 versus 21.6, p<0.001, vacuum amount: 38.0 versus 14.0, p<0.01). Additionally, the water jet function of the BT-S was not inferior. In 39 colorectal ESD cases in two institutions, there were mean 4.7 times (range: 1–28) of knife insertion. Suction under knife happened 59% (23/39) and suction of fluid could be done in 100%. Conclusions. Our study showed that the narrow knife allows significantly faster knife insertion, better vacuum function, and effective clinical results
    corecore