63 research outputs found
Assessment of the brain function by evoked potentials: analysis of the late components of visual evoked potentials recorded from the vertex
Visual evoked potentials recorded from the vertex were studied in seventy four individuals with mental retardation,ranging from l old to 50 years old. They were classified into 4 groups according to the level of IQ/DQ,and the relation between the late components and the intellectual level was exarnined. In 9 of 74 cases(12.2%),la tency of the N130 component was prolonged and in 7
of 74 cases (9.6%),the P190 component was prolonged. There was,however,no correlation
between the number of the cases with prolonged N130 or P190 latency and the level of IQ/DQ.
Cases with prolongation in N130 and/or Pl90 were almost exclusively found among those with such complications as cerebral palsy and/or epilepsy,while few cases without complications
showed prolongation. From these results,it is suggested that the prolongation in the late components developes reflecting the presence of the organic lesions that have a common causative
potent producing cerebral palsy and/or epilepsy
The Q223R polymorphism in the leptin receptor associates with objectively measured light physical activity in free-living Japanese
AbstractPhysical activity (PA) is associated with reductions in the risk of all-cause mortality and in the prevalence of cardiovascular disease and stroke. Nevertheless, a large proportion of the general population may not be sufficiently active. PA level has been reported to be influenced by genetic factors, and we investigated whether Q223R polymorphism in the leptin receptor (LEPR) gene was associated with PA level. A total of 556 Japanese adults aged 24–65years old participated in this cross-sectional study. The duration and intensity of PA were objectively evaluated by triaxial accelerometry. Q223R polymorphism was determined by the TaqMan method. The distribution of Q223R polymorphism was: QQ 0.7%, QR 22.6%, and RR 76.6%. The relation between the LEPR genotype and PA level was analyzed by ANCOVA with age and sex as covariates in the Q dominant genetic model. There were significant differences between LEPR genotypes and the time spent in light PA or inactive time. The subjects with RR genotype showed significantly shorter time spent in light PA (RR genotype: 559.4±102.9min/day, QQ/QR genotype: 579.9±103.1min/day) and longer inactive time (RR genotype: 815.5±107.5min/day, QQ/QR genotype: 792.3±107.7min/day) than the subjects with QQ/QR genotype (P<0.05). There were no such differences in the time spent in moderate or vigorous PA. These results suggest that the variety of PA level, especially spontaneous PA in humans, is partly caused by diversity in the LEPR gene
Psychophysical evaluation of calibration curve for diagnostic LCD monitor
金沢大学大学院医学系研究科量子医療技術学Purpose. In 1998, Digital Imaging Communications in Medicine (DICOM) proposed a calibration tool, the grayscale standard display function (GSDF), to obtain output consistency of radiographs. To our knowledge, there have been no previous reports of investigating the relation between perceptual linearity and detectability on a calibration curve. Materials and methods. To determine a suitable calibration curve for diagnostic liquid crystal display (LCD) monitors, the GSDF and Commission Internationale de l\u27Eclairage (CIE) curves were compared using psychophysical gradient δ and receiver operating characteristic (ROC) analysis for clinical images. Results. We succeeded in expressing visually recognized contrast directly using δ instead of the just noticeable difference (JND) index of the DICOM standard. As a result, we found that the visually recognized contrast at low luminance areas on the LCD monitor calibrated by the CIE curve is higher than that calibrated by the GSDF curve. On the ROC analysis, there was no significant difference in tumor detectability between GSDF and CIE curves for clinical thoracic images. However, the area parameter Az of the CIE curve is superior to that of the GSDF curve. The detectability of tumor shadows in the thoracic region on clinical images using the CIE curve was superior to that using the GSDF curve owing to the high absolute value of δ in the low luminance range. Conclusion. We conclude that the CIE curve is the most suitable tool for calibrating diagnostic LCD monitors, rather than the GSDF curve. © Japan Radiological Society 2006
The Importance of Suppressing Pathological Periostin Splicing Variants with Exon 17 in Both Stroma and Cancer
Shibata Kana, Koibuchi Nobutaka, Sanada Fumihiro, et al. The Importance of Suppressing Pathological Periostin Splicing Variants with Exon 17 in Both Stroma and Cancer. Cells 13, 1410 (2024); https://doi.org/10.3390/cells13171410.Background: Periostin (POSTN) is a type of matrix protein that functions by binding to other matrix proteins, cell surface receptors, or other molecules, such as cytokines and proteases. POSTN has four major splicing variants (PN1–4), which are primarily expressed in fibroblasts and cancer. We have reported that we should inhibit pathological POSTN (PN1–3), but not physiological POSTN (PN4). In particular, pathological POSTN with exon 17 is present in both stroma and cancer, but it is unclear whether the stroma or cancer pathological POSTN should be suppressed. Methods and Results: We transplanted 4T1 cells (breast cancer) secreting POSTN with exon 17 into 17KO mice lacking POSTN exon 17 to suppress stromal POSTN with exon 17. The results show that 17KO mice had smaller primary tumors and fewer metastases. Furthermore, to suppress cancer POSTN with exon 17, 4T1 cells transfected with POSTN exon 17 skipping oligo or control oligo were transplanted from the tail vein into the lungs. The results show that POSTN exon 17 skipping oligo significantly suppressed lung metastasis. Conclusions: These findings suggest that it is important to suppress POSTN exon 17 in both stroma and cancer. Antibody targeting POSTN exon 17 may be a therapeutic candidate for breast cancer
Pulmonary blood flow evaluation using a dynamic flat-panel detector: Feasibility study with pulmonary diseases
金沢大学医薬保健研究域保健学系Purpose: Pulmonary ventilation and circulation dynamics are reflected on fluoroscopic images as changes in X-ray translucency. The purpose of this study was to investigate the feasibility of non-contrast functional imaging using a dynamic flat-panel detector (FPD). Methods: Dynamic chest radiographs of 20 subjects (abnormal, n = 12; normal, n = 8) were obtained using the FPD system. Image analysis was performed to get qualitative perfusion mapping image; first, focal pixel value was defined. Second, lung area was determined and pulmonary hilar areas were eliminated. Third, one cardiac cycle was determined in each of the cases. Finally, total changes in pixel values during one cardiac cycle were calculated and their distributions were visualized with mapping on the original image. They were compared with the findings of lung perfusion scintigraphy. Results: In all normal controls, the total changes in pixel value in one cardiac cycle decreased from the hilar region to the peripheral region of the lung with left-right symmetric distribution. In contrast, in many abnormal cases, pulmonary blood flow disorder was indicated as a reduction of changes in pixel values on a mapping image. The findings of mapping image coincided with those of lung perfusion scintigraphy. Conclusions: Dynamic chest radiography using an FPD system with computer analysis is expected to be a new type of functional imaging, which provides pulmonary blood flow distribution additionally. © CARS 2009
Preliminary investigation of the clinical usefulness of super-high-resolution LCDs with 9 and 15 mega-sub-pixels: Observation studies with phantoms
金沢大学附属病院放射線部Our purpose in this study was to evaluate the preliminary clinical efficacy of soft-copy reading of digital mammography, for a 15-mega-sub-pixel (MsP) and a 9-MsP super-high-resolution liquid-crystal display (SHR-LCD) by use of an independent sub-pixel driving technology. We performed three kinds of phantom observation studies by six radiological technologists. Detectability of a contrast-detail phantom and simulated small objects (SSOs) resembling microcalcifications (MCLs), and shape discrimination ability of SSOs with round and square shapes, were examined and compared with a 5-MP conventional LCD (5-MP LCD). In each study, four types of display magnification ratio were used. The detectability and the shape discrimination ability of the 15-MsP SHR-LCD were highest among the three LCDs of most of the display magnification ratios. The 9-MsP SHR-LCD indicated a higher or equal performance as compared with the 5-MP LCD in the SSO detection and shape studies. The results of our study demonstrated that the SHR-LCDs had good potential to detect MCLs and to evaluate the shape in high-resolution digital mammography. © 2009 Japanese Society of Radiological Technology and Japan Society of Medical Physics
Development of pulmonary blood flow evaluation method with a dynamic flat-panel detector: quantitative correlation analysis with findings on perfusion scan
金沢大学医薬保健研究域保健学系Pulmonary blood flow is reflected in dynamic chest radiographs as changes in X-ray translucency, i.e., pixel values. Thus, decreased blood flow should be observed as a reduction of the variation of X-ray translucency. We performed the present study to investigate the feasibility of pulmonary blood flow evaluation with a dynamic flat-panel detector (FPD). Sequential chest radiographs of 14 subjects were obtained with a dynamic FPD system. The changes in pixel value in each local area were measured and mapped on the original image by use of a gray scale in which small and large changes were shown in white and black, respectively. The resulting images were compared to the findings in perfusion scans. The cross-correlation coefficients of the changes in pixel value and radioactivity counts in each local area were also computed. In all patients, pulmonary blood flow disorder was indicated as a reduction of changes in pixel values on the mapping image, and a correlation was observed between the distribution of changes in pixel value and those in radioactivity counts (0.7 ≤ r, 3 cases; 0.4 ≤ r < 0.7, 7 cases; 0.2 ≤ r < 0.4, 4 cases). The results indicated that the distribution of changes in pixel value could provide a relative measure related to pulmonary blood flow. The present method is potentially useful for evaluating pulmonary blood flow as an additional examination in conventional chest radiography. © 2009 Japanese Society of Radiological Technology and Japan Society of Medical Physics
Neutrophil elastase in amniotic fluid as a predictor of preterm birth after emergent cervical cerclage
Introduction. The aim of this study was to investigate neutrophil elastase (NE) in amniotic fluid as a potential marker for predicting pregnancy continuation. Material and methods. We enrolled 34 pregnant women with bulging fetal membrane during the second trimester who underwent emergent cerclage after confirming the absence of intrauterine infection (amniotic fluid glucose >= 15 mg/dL). Amniotic fluid NE levels were compared between women who completed and did not complete 30, 34, and 36 weeks of gestation, and the optimal cut-off value for predicting pregnancy continuation was estimated. Moreover, the differences in the duration of continued pregnancy were compared between women with NE levels above and below the optimal cut-off value. Results. The optimal cut-off value for NE in amniotic fluid that predicted pregnancy continuation beyond 30, 34, and 36 weeks of gestation was 180 ng/mL; this cut-off value had a sensitivity, specificity, positive predictive value, and negative predictive value of 84.0, 77.8, 91.3, and 63.7% beyond 30 weeks of gestation; 87.5, 80.0, 91.5, and 72.3% beyond 34 weeks of gestation; and 85.0, 71.4, 80.9, and 76.9% beyond 36 weeks of gestation, respectively. The duration of continued pregnancy from emergent cerclage to delivery was significantly longer in women with amniotic fluid NE = 180 ng/mL (44.8 +/- 14.3 days). Conclusion. The NE levels in amniotic fluid may serve as a useful marker for predicting the duration of continued pregnancy after cervical cerclage
Association between Washing Residue on the Feet and Tinea Pedis in Diabetic Patients
Tinea pedis (TP) may lead to the development of foot ulcers in diabetic patients; thus, its prevention in diabetic patients is important. TP occurs after dermatophytes on the skin scales of TP patients attach to the feet. Therefore, it is necessary to remove the scales and dermatophytes, and this can be performed using various methods, including foot washing. This study aimed to objectively examine the association between the presence of TP and foot-washing habits. We included 33 diabetic patients, and, of these, 17 had TP. The presence of washing residue on the feet was determined by applying a fluorescent cream to the participants’ feet, and images of the feet were captured under ultraviolet light before and after foot washing. Our results showed that diabetic patients with TP had higher levels of washing residue on their feet than those without TP. The importance of washing feet to prevent TP needs to be emphasized through educational programs for diabetic patients. Furthermore, the development of an effective foot-washing technique is essential
Diagnostic specificity of the child psychosis-risk screening system with a focus on the differentiation of schizophrenia spectrum disorders and neurodevelopmental disorders
BackgroundResearch on early psychosis has begun to identify psychiatric characteristics of the prodromal period of schizophrenia; however, subclinical characteristics of children in non-psychiatric fields have not been fully investigated. In our previous study, we developed the Child Psychosis-risk Screening System (CPSS).ObjectiveIn the present cross-sectional study, we attempted to identify the risk of developing psychosis in pediatric (n = 216) and psychiatric outpatients (n = 120), aged 6– 18 years, with the CPSS.MethodsAn analysis of variance of CPSS risk was performed in six diagnostic categories to examine specificity for each diagnosis. Receiver operating characteristic (ROC) curve analysis was conducted using the onset of schizophrenia spectrum as the outcome, and the discriminatory power and cut off values of the CPSS were determined. Logistic regression analysis was performed using clinical data to identify factors associated with the risk group (those at high risk of developing psychosis in the future) identified using the CPSS.ResultsThere were significant differences in risk variance among diagnostic categories (p < 0.001), especially between schizophrenia spectrum disorders (SSD) and neurodevelopmental disorders (p = 0.001). CPSS had sufficient discriminatory power for SSD diagnosis [area under the ROC curve = 0.853 (95% confidence interval: 0.774–0.931)]. The cut off value for the risk of SSD was determined to be 98.1%, achieving the best mean of the sum of sensitivity (90.9%) and specificity (84.0%). Cross-sectional logistic regression analysis showed that along with “SSD diagnosis,” “winter birth,” and “maltreatment” were factors associated with the risk group (odds ratio = 38.05 [p = 0.001], 2.30 [p = 0.016], and 0.12 [p = 0.024], respectively).ConclusionCPSS may have potential use in the early detection of psychosis and differentiation from neurodevelopmental disorders, but this study was small and further studies with larger sample sizes and longitudinal study designs are required prior to its use in routine clinical practice
- …