691 research outputs found

    Magnetic Properties of Spheroidal Graphite Cast Iron

    Get PDF
    The magnetic properties of spheroidal and flake graphite cast irons of similar composition cast into sand moulds of various diameters were measured, and the results obtained were as follows : Under the same degree of graphitization, the maximum induction, the coercive force and the hysteresis loss of spheroidal graphite cast iron were lower than those of flake graphite cast iron, and so the maximum permeability and the residual induction were higher. With increasing degree of graphitization, the maximum permeability increased, whereas the other four quantities decreased

    Hardness of Instance Generation with Optimal Solutions for the Stable Marriage Problem

    Get PDF
    In a variant of the stable marriage problem where ties and incomplete lists are allowed, finding a stable matching of maximum cardinality is known to be NP-hard. There are a lot of experimental studies for evaluating the performance of approximation algorithms or heuristics, using randomly generated or artificial instances. One of standard evaluation methods is to compare an algorithm's solution with an optimal solution, but finding an optimal solution itself is already hard. In this paper, we investigate the possibility of generating instances with known optimal solutions. We propose three instance generators based on a known random generation algorithm, but unfortunately show that none of them meet our requirements, implying a difficulty of instance generation in this approach

    Apatite-forming ability of vinylphosphonic acid-based copolymer in simulated body fluid: effects of phosphate group content

    Get PDF
    Phosphate groups on materials surfaces are known to contribute to apatite formation upon exposure of the materials in simulated body fluid and improved affinity of the materials for osteoblast-like cells. Typically, polymers containing phosphate groups are organic matrices consisting of apatite–polymer composites prepared by biomimetic process using simulated body fluid. Ca2+ incorporation into the polymer accelerates apatite formation in simulated body fluid owing because of increase in the supersaturation degree, with respect to apatite in simulated body fluid, owing to Ca2+ release from the polymer. However, the effects of phosphate content on the Ca2+ release and apatite-forming abilities of copolymers in simulated body fluid are rather elusive. In this study, a phosphate-containing copolymer prepared from vinylphosphonic acid, 2-hydroxyethyl methacrylate, and triethylene glycol dimethacrylate was examined. The release of Ca2+ in Tris-NaCl buffer and simulated body fluid increased as the additive amount of vinylphosphonic acid increased. However, apatite formation was suppressed as the phosphate groups content increased despite the enhanced release of Ca2+ from the polymer. This phenomenon was reflected by changes in the surface zeta potential. Thus, it was concluded that the apatite-forming ability of vinylphosphonic acid-2-hydroxyethyl methacrylate-triethylene glycol dimethacrylate copolymer treated with CaCl2 solution was governed by surface state rather than Ca2+ release in simulated body fluid

    Bioactive PMMA bone cement modified with combinations of phosphate group-containing monomers and calcium acetate

    Get PDF
    Bone cement from polymethylmethacrylate powder and methylmethacrylate liquid has been successfully demonstrated as artificial material to anchor joint replacements in bone. However, it lacks the capability to bond directly to bone, so long-term implantation leads to an increased risk of loosening. Bioactive materials show better performance in fixation to bone, and the chemical bonding depends on bone-like apatite formation. This is triggered by surface reactions with body fluid. For these reactions, superficial functional groups like silanol (Si–OH) are ideal sites to induce apatite nucleation and the release of Ca2+ ions accelerates the apatite growth. Therefore, incorporation of materials containing these key components may provide the cement with apatite-forming ability. In this study, phosphoric acid 2-hydroxyethyl methacrylate ester or bis[2-(methacryloyloxy)ethyl] phosphate supplying a phosphate group (PO4H2) was added into methylmethacrylate liquid, while calcium acetate as a source of Ca2+ ions was mixed into polymethylmethacrylate powder. The influences of the combinations on the setting time and compressive strength were also investigated. Apatite was formed on the cements modified with 30 mass% of phosphoric acid 2-hydroxyethyl methacrylate ester or bis[2-(methacryloyloxy)ethyl] phosphate. The induction period was shortened with increased amounts of Ca(CH3COO)2. The setting time could be controlled by the Ca(CH3COO)2/monomer mass ratio. Faster setting was achieved at a ratio close to the mixing ratio of the powder/liquid (2:1), and both increases and decreases in the amount of Ca(CH3COO)2 prolonged the setting time based on this ratio. The highest compressive strength was 88.8 ± 2.6 MPa, higher than the lowest limit of ISO 5833 but was lower than that of the simulated body fluid-soaked reference. The increase of additives caused the decline in compressive strength. In view of balancing apatite formation and clinical standard, bis[2-(methacryloyloxy)ethyl] phosphate is more suitable as an additive, and the optimal modification is a combination of 30 mass% of bis[2-(methacryloyloxy)ethyl] phosphate and 20 mass% of Ca(CH3COO)2

    Apatite formation on a hydrogel containing sulfinic acid group under physiological conditions

    Get PDF
    Natural bone consists of apatite and collagen fiber. Bioactive materials capable to bonding to bone tissue are clinically used as bone-repairing materials. Apatite-organic polymer composites exhibit bone-bonding abilities and mechanical properties similar to those of natural bone, and these materials can be prepared using biomimetic processes in simulated body fluid (SBF). Specific functional groups such as sulfonic and carboxylic acid groups are known to induce the heterogeneous nucleation of apatite in SBF. However, it remains unclear whether structurally related sulfinic acid groups can contribute to apatite formation in the same way, despite sodium sulfonate being used in biomedical applications as a radical polymerization promoter in adhesive dental resin. Herein, we report the preparation of a new hydrogel containing sulfinic acid groups from sodium 4-vinylbenzenesulfinate and 2-hydroxyethyl methacrylate using a radical polymerization reaction and the subsequent incorporation of Ca2+ ions into this material. We also investigated the apatite-forming behavior of these hydrogels in SBF. Hydrogels containing sulfinic acid groups showed higher apatite-forming ability than those without sulfinic acid groups. In addition, the apatite layer formed on the former showed tight adhesion to the hydrogel. This phenomenon was attributed to the heterogeneous nucleation of apatite, induced by the sulfinic acid groups

    Bioactive Carbon-PEEK Composites Prepared by Chemical Surface Treatment

    Get PDF
    Polyetheretherketone (PEEK) has attracted much attention as an artificial intervertebral spacer for spinal reconstruction. Furthermore, PEEK plastic reinforced with carbon fiber has twice the bending strength of pure PEEK. However, the PEEK-based materials do not show ability for direct bone bonding, i.e., bioactivity. Although several trials have been conducted for enabling PEEK with bioactivity, few studies have reported on bioactive surface modification of carbon–PEEK composites. In the present study, we attempted the preparation of bioactive carbon-PEEK composites by chemical treatments with H2SO4 and CaCl2. Bioactivity was evaluated by in vitro apatite formation in simulated body fluid (SBF). The apatite formation on the carbon–PEEK composite was compared with that of pure PEEK. Both pure PEEK and carbon-PEEK composite formed the apatite in SBF when they were treated with H2SO4 and CaCl2; the latter showed higher apatite-forming ability than the former. It is conjectured that many functional groups able to induce the apatite nucleation, such as sulfo and carboxyl groups, are incorporated into the dispersed carbon phase in the carbon–PEEK composites

    Biomineralization behavior of a vinylphosphonic acid-based copolymer added with polymerization accelerator in simulated body fluid

    Get PDF
    AbstractApatite-polymer composites have been evaluated in terms of its potential application as bone substitutes. Biomimetic processes using simulated body fluid (SBF) are well-known methods for preparation of such composites. They are reliant on specific functional groups to induce the heterogeneous apatite nucleation and phosphate groups possess good apatite-forming ability in SBF. Improving the degree of polymerization is important for obtaining phosphate-containing polymers, because the release of significant quantities of monomer or low molecular weight polymers can lead to suppression of the apatite formation. To date, there have been very few studies pertaining to the effect of adding a polymerization accelerator to the polymerization reaction involved in the formation of these composite materials under physiological conditions. In this study, we have prepared a copolymer from triethylene glycol dimethacrylate and vinylphosphonic acid (VPA) in the presence of different amounts of sodium p-toluenesulfinate (p-TSS) as a polymerization accelerator. The effects of p-TSS on the chemical durability and apatite formation of the copolymers were investigated in SBF. The addition of 0.1–1.0wt% of p-TSS was effective for suppressing the dissolution of the copolymers in SBF, whereas larger amount had a detrimental effect. A calcium polyvinylphosphate instead of the apatite was precipitated in SBF

    Formation and luminescence studies of Ge/Si core-shell quantum dots

    Get PDF
    Si-based quantum dots (QDs) have attracted much attention as an active element in Si-based optoelectronic applications because their light emission properties due to carrier confinement have the potential to combine photonic processing with electronic processing on a single chip. We have focused on CVD formation and characterization of Si-QDs with Ge core and reported their photoluminescence (PL) properties attributable to type II energy-band alignment between the Ge–core and the Si-shell [1-2]. In addition, we have also demonstrated stable electroluminescence in the near–infrared region from diode structures having a 3-fold stacked Si-QDs with Ge core with an areal dot density of ~2.0×1011 cm−2 under pulsed bias applications [3]. To gain fundamental knowledge and better understanding of the PL properties and to enhance the radiative recombination rate in photoexcited QDs, it would be effective to increase electronic states assisting radiative transition with impurity doping into the QDs and to reduce or not to increase in non-radiative centers if any. Please click Download on the upper right corner to see the full abstract

    Angle Control of a Pneumatically Driven Musculoskeletal Model Based on Coordination of Agonist-Antagonist Muscle

    Get PDF
    In recent years, researchers have been actively pursuing research into developing robots that can be useful in many fields of industry (e.g., service, medical, and aging care). Such robots must be safe and flexible so that they can coexist with people. Pneumatic actuators are useful for achieving this goal because they are lightweight units with natural compliance. Our research focuses on joint angle control for a pneumatically driven musculoskeletal model. In such a model, we use a one-degree-of-freedom joint model and a five-fingered robot hand as test beds. These models are driven by low pressure-driven pneumatic actuators, and mimic the mechanism of the human hand and musculoskeletal structure, which has an antagonistic muscle pair for each joint. We demonstrated a biologically inspired control method using the parameters antagonistic muscle ratio and antagonistic muscle activity. The concept of the method is based on coordination of an antagonistic muscle pair using these parameters. We have investigated the validity of the proposed method both theoretically and experimentally, developed a feedback control system, and conducted joint angle control by implementing the test beds.ArticleJournal of Mechanics Engineering and Automation. 2(12):709-719 (2012)journal articl
    corecore