273 research outputs found

    Individually separated supramolecular polymer chains toward solution-processable supramolecular polymeric materials

    Get PDF
    Herein, we present a simple design concept for a monomer that affords individually separated supramolecular polymer chains. Random introduction of alkyl chains with different lengths onto a monomer prevented its supramolecular polymers from bundling, permitting the preparation of concentrated solutions of the supramolecular polymer without gelation, precipitation, or crystallization. With such a solution in hand, we succeeded in fabricating self-standing films and threads consisting of supramolecular polymers

    The estimated GFR, but not the stage of diabetic nephropathy graded by the urinary albumin excretion, is associated with the carotid intima-media thickness in patients with type 2 diabetes mellitus: a cross-sectional study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To study the relationship between the intima-media thickness (IMT) of the carotid artery and the stage of chronic kidney disease (CKD) based on the estimated glomerular filtration rate (eGFR) and diabetic nephropathy graded by the urinary albumin excretion (UAE) in the patients with type 2 diabetes mellitus.</p> <p>Methods</p> <p>A cross-sectional study was performed in 338 patients with type 2 diabetes mellitus. The carotid IMT was measured using an ultrasonographic examination.</p> <p>Results</p> <p>The mean carotid IMT was 1.06 ± 0.27 mm, and 42% of the subjects showed IMT thickening (≥ 1.1 mm). Cerebrovascular disease and coronary heart disease were frequent in the patients with IMT thickening. The carotid IMT elevated significantly with the stage progression of CKD (0.87 ± 0.19 mm in stage 1, 1.02 ± 0.26 mm in stage 2, 1.11 ± 0.26 mm in stage 3, and 1.11 ± 0.27 mm in stage 4+5). However, the IMT was not significantly different among the various stages of diabetic nephropathy. The IMT was significantly greater in the diabetic patients with hypertension compared to those without hypertension. The IMT positively correlated with the age, the duration of diabetes mellitus, and the brachial-ankle pulse wave velocities (baPWV), and negatively correlated with the eGFR. In a stepwise multivariate regression analysis, the eGFR and the baPWV were independently associated with the carotid IMT.</p> <p>Conclusions</p> <p>Our study is the first report showing a relationship between the carotid IMT and the renal parameters including eGFR and the stages of diabetic nephropathy with a confirmed association between the IMT and diabetic macroangiopathy. Our study further confirms the importance of intensive examinations for the early detection of atherosclerosis and positive treatments for hypertension, dyslipidaemia, obesity, as well as hyperglycaemia are necessary when a reduced eGFR is found in diabetic patients.</p

    Long-term effect of metformin on blood glucose control in non-obese patients with type 2 diabetes mellitus

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We aimed to investigate the long-term effect of metformin on the blood glucose control in non-obese patients with type 2 diabetes mellitus.</p> <p>Methods</p> <p>A retrospective study was performed in 213 patients with type 2 diabetes mellitus under the administration of metformin for more than one year. The clinical parameters were investigated for 3 years. The obese and non-obese individuals were defined as a body mass index (BMI) of 25 kg/m<sup>2 </sup>or over (<it>n </it>= 105) and a BMI of less than 25 kg/m<sup>2 </sup>(<it>n </it>= 108), respectively.</p> <p>Results</p> <p>HbA1c levels were significantly decreased compared with those at the baseline time. The course of HbA1c was similar between the non-obese and the obese groups, while the dose of metformin required to control blood glucose was significantly lower in the non-obese group than in the obese group. The reductions in HbA1c were 1.2% and 1.1% at 12 months, 0.9% and 0.9% at 24 months, and 0.8% and 1.0% at 36 months in the non-obese and obese groups, respectively. BMI did not change during the observation periods. Approximately half of all patients required no additional antidiabetic agents or a reduction in other treatments after the initiation of metformin in either of the two groups.</p> <p>Conclusions</p> <p>The present study demonstrated the long-term beneficial effect of metformin in non-obese (BMI < 25 kg/m<sup>2</sup>) diabetic patients. This effect appears to be maintained even after the observation period of this study, because metformin was limited to a relatively low dose in the non-obese group and the observed worsening in glycemic control over time can probably be attenuated by increasing the dose of metformin.</p

    Fabrication of Planar Power Inductor for Embedded Passives in LSI Package for Hundreds Megahertz Switching DC–DC Buck Converter

    Get PDF
    Recently, research and development of integrated low-voltage dc-dc converter to LSIs has been active. In order to realize such integrated dc power supply, power magnetic devices must be integrated in it. The authors have fabricated planar power inductor embedded in LSI package for hundreds megahertz switching dc-dc buck converter. In this study, two types of planar power inductors have been fabricated: one was spin-sprayed Zn-ferrite thick film magnetic core inductor, and the other was composite magnetic core (Fe-based amorphous/polyimide) inductor. Footprint of the fabricated inductors was 850 x 850 mu m(2), their inductance was about 10 nH, and the quality factor Q was about 20 at 100 MHz. The rating current which depends on the superimposed dc characteristic was at least up to 2 A.ArticleIEEE TRANSACTIONS ON MAGNETICS. 47(10):3204-3207 (2011)journal articl

    Hypertension resistant to antihypertensive agents commonly occurs with the progression of diabetic nephropathy in Japanese patients with type 2 diabetes mellitus: a prospective observational study

    Get PDF
    BACKGROUND: We investigated 1) the frequency of hypertension in patients with type 2 diabetes graded by the new classification of chronic kidney disease (CKD) reported by the Kidney Disease: Improving Global Outcomes (KDIGO) and 2) the number of antihypertensive agents needed to achieve treatment goals using a prospective observational study. METHODS: A population of 2018 patients with type 2 diabetes mellitus was recruited for the study. The CKD stage was classified according to the eGFR and the urinary albumin excretion levels. RESULTS: Hypertension was found in 1420 (70%) of the patients, and the proportion of subjects showing a blood pressure < 130/80 mmHg was 31% at the baseline. Although the mean blood pressure was approximately 130/75 mmHg, the rate of patients with a blood pressure of < 130/80 mmHg became limited to 41-50% during the observation period. The number of antihypertensive agents required for treatment was significantly higher at the endpoint (2.0 ± 1.3) than at the baseline (1.6 ± 1.2). Furthermore, it increased with the progression of the CKD stage at both the baseline and the endpoint of the observation. However, the frequency of subjects who did not achieve the blood pressure target was found to increase in the group demonstrating the later stage of CKD. CONCLUSIONS: Hypertension resistant to antihypertensive agents was common in the patients with type 2 diabetes mellitus and increased with the progression of CKD. Although powerful combination therapy using antihypertensive agents is considered necessary for the strict control of blood pressure, this became difficult in individuals who were in advanced stages as graded based on the eGFR and the urinary albumin excretion levels

    Quantitative assessment of coronary stenosis by harmonic power Doppler with a simple pulsing sequence and vasodilator stress in patients

    Get PDF
    AbstractObjectivesWe examined whether myocardial contrast echocardiography (MCE) with harmonic power Doppler (HPD) employing a simple ultrasound pulsing sequence enables estimation of the severity of coronary artery stenosis in patients.BackgroundContrast intensity (CI) during MCE with intravenous microbubble infusion is dependent on the myocardial blood flow velocity (MBFV) and pulsing interval (PI).MethodsBased on an in vitro experiment, we devised the MBFV index calculated as the reciprocal of the magnitude of CI decay produced by abrupt PI shortening during intermittent imaging. In 68 coronary artery territories from 49 patients, myocardial HPD images were acquired during intravenous infusion of Levovist, while the long PI with 1:10 electrocardiographic gating was shortened to 1:1, both at baseline and during adenosine triphosphate infusion. The MBFV index in each coronary territory and MBFV reserve as the ratio between hyperemia and baseline were compared with the severity of corresponding coronary artery stenosis assessed by quantitative coronary angiography (QCA) or by pressure guide wire as the fractional flow reserve (FFR).ResultsBoth the MCE-derived MBFV index during hyperemia and MBFV reserve exhibited significant negative correlations with the QCA-derived stenosis severity (r = −0.56 and r = −0.64, respectively). The MBFV reserve positively correlated with FFR (r = 0.89). By combining the cutoff values of the MBFV index during hyperemia and MBFV reserve, ≥75% of stenoses defined by QCA were determined, with a sensitivity of 77.3%, specificity of 93.4%, and accuracy of 88.3%.ConclusionsShortening of PI during intravenous MCE with intermittent HPD imaging under vasodilator stress enables assessment of coronary artery stenoses in patients

    Fabrication of Planar Power Inductor for Embedded Passives in LSI Package for Hundreds Megahertz Switching DC-DC Buck Converter

    Get PDF
    Recently, research and development of integrated low-voltage dc-dc converter to LSIs has been active. In order to realize such integrated dc power supply, power magnetic devices must be integrated in it. The authors have fabricated planar power inductor embedded in LSI package for hundreds megahertz switching dc-dc buck converter. In this study, two types of planar power inductors have been fabricated: one was spin-sprayed Zn-ferrite thick film magnetic core inductor, and the other was composite magnetic core (Fe-based amorphous/polyimide) inductor. Footprint of the fabricated inductors was 850 x 850 mu m(2), their inductance was about 10 nH, and the quality factor Q was about 20 at 100 MHz. The rating current which depends on the superimposed dc characteristic was at least up to 2 A.ArticleIEEE TRANSACTIONS ON MAGNETICS. 47(10):3204-3207 (2011)journal articl
    corecore