22 research outputs found
Эталоны-копии единицы массы: калибровка 2020 года с применением вакуумного компаратора CCL 1007
The article discusses the calibration results of reference standards-copies according to the State Primary Standard of the Mass Unit using the new CCL 1007 vacuum comparator and buoyancy artifacts. The authors provided historical data on the calibrations of copies of the International Prototype of the Kilogram (IPK) starting from 1892, including the Russian prototype № 12. The instability of the prototype of the kilogram No. 12 corresponds to international values and is assessed at 5 · 10–11 kg per year. Changes in the mass of copies are assessed in relation to the mass of the IPK, but it is impossible to determine to what extent it has changed. This was the reason for the adoption of a new value of the kilogram. Following the adoption at the 26th meeting of the General Conference on Weights and Measures (CGPM) held in Paris in November 2018, Planck constant was numerically established with absolute accuracy, and total uncer tainty of 1 · 10–8 kg was assigned to the mass of the IPK. Thus, the authors set the aim to preserve the numerical value of the total uncertainty of the reference standards-copies by reducing the transfer error of the State Primary Standard by 10 times. The article presents the calibration results of six reference standards-copies in relation to prototype No. 12 with the primary data processing using the method of least squares, and the uncertainty budget is provided. The calibration results of the reference standards-copies confirmed the accuracy increase of the transfer unit by 10 times in the range from 6 · 10–9 kg to 6 · 10–10 kg by the use of a vacuum comparator graduated 0.1 μg and buoyancy and sorption artifacts in direct measurements of air density. This has made it possible to compensate for the additional uncertainty attributed to the IPK based on the determination of the Planck constant value and to ensure the mass calibration of all accuracy grades preserving the entire hierarchical system of transferring the mass unit in the country.В статье рассматриваются результаты калибровки эталонов-копий по Государственному первичному эталону единицы массы – килограмм ГЭТ 3–2020 с применением нового вакуумного компаратора CCL 1007 и артефактов плавучести. Авторы привели исторические данные калибровок копий Международного прототипа килограмма начиная с 1892 г., в т. ч. российский прототип № 12. Значения нестабильности прототипа килограмма № 12 соответствуют международным значениям и оценивается как 5 · 10–11 кг за год. Изменения массы копий оцениваются относительно массы Международного прототипа килограмма, а насколько изменился он сам – сказать принципиально невозможно, что стало причиной перехода на новое определение килограмма. После принятия на 26-м заседании Генеральной конференции по мерам и весам, состоявшейся в Париже в ноябре 2018 г., постоянная Планка была численно зафиксирована с абсолютной точностью, а массе Международного прототипа килограмма приписана суммарная неопределенность 1 · 10–8 кг. Отсюда авторами поставлена задача сохранить численное значение суммарной неопределенности эталонов-копий за счет снижения в 10 раз погрешности передачи от ГЭТ 3–2020. В статье приведены результаты калибровки шести эталонов-копий по отношению к прототипу № 12 с обработкой первичных данных по методу наименьших квадратов и представлен бюджет неопределенности измерений. Результаты калибровки эталонов-копий подтвердили повышение точности передачи единицы в 10 раз – с 6 · 10–9 кг до 6 · 10–10 кг – за счет применения вакуумного компаратора с ценой деления 0,1 мкг и артефактов плавучести и сорбции при прямых измерениях плотности воздуха. Это позволило скомпенсировать дополнительную неопределенность, приписанную МПК на основе фиксации числового значения постоянной Планка, и тем самым обеспечить поверку гирь всех классов точности с сохранением всей сложившейся иерархической системы передачи единицы массы в стране
Тонометрическое внутриглазное давление у взрослого населения: популяционное исследование
PURPOSE: To study the distribution of intraocular pressure (IOP) obtained by Maklakov tonometry in different age groups.METHODS: The study evaluated Caucasians without glaucoma aged 45-75. The participants underwent Maklakov tonometry with a 10 g tonometer at 09:00-12:00 with subsequent imprint evaluation by means of NesterovEgorov scale, measurements of central corneal thickness (CCT) and visual acuity. All the participants were divided into 3 groups by age: Group 1 consisted of participants aged 45-55, Group 2 comprised the ones aged 56-65, Group 3 included patients aged 66-75.RESULTS: In total 791 person were enrolled; 1 429 of 1 499 eyes (95.3%) were accepted into the study. IOP in Group I was 16.1±3.3 mmHg in Group 1; 16.3±3.3 in Group 2; 16.2±3.5 mmHg in Group 3. CCT in Group 1 was 545.7±14.6 μm; 545.3±15.4 μm in Group 2; 544.7±14.6 μm in Group 3. Visual acuity was 0.93±0.13 in Group 1; 0.89±0.15 in Group 2; 0.81±0.18 in Group 3. Average IOP in men was 16.4±3.3 mmHg, in women 16.5±3.3 mmHg. Age, vision acuity, CCT and IOP were within the normal distribution; IOP and CCT had no significant differences between the age groups. The measured parameters showed no significant intercorrelation. We found no significant difference between IOP in men and women.CONCLUSION: In a healthy population CCT and IOP values fall within a normal distribution and do not change significantly with age. IOP does not depend on sex. Average IOP in the studied population is 16.2±3.4 mmHg, average CCT is 545.3±15.1 μm.ЦЕЛЬ. Исследовать возрастные нормы внутриглазного давления (ВГД) при использовании тонометрии по Маклакову.МЕТОДЫ. Обследовали лиц европеоидной расы без глаукомы в возрасте 45-75 лет. Исследуемым измеряли ВГД тонометром Маклакова весом 10 грамм в период с 9:00 до 12:00 с последующей оценкой отпечатка по линейке Нестерова - Егорова, измеряли центральную толщину роговицы (ЦТР) и проверяли остроту зрения. Всех исследуемых разделили на три группы по возрасту: группа 1 — 45-55 лет, группа 2 — 56-65 лет, группа 3 — 66-75 лет.РЕЗУЛЬТАТЫ. Обследован 791 человек; из 1 499 глаз приняты 1 429 (95,3%). ВГД составило в группе 1 — 16,1±3,3 мм рт.ст.; в группе 2 — 16,3±3,3 мм рт.ст.; в группе 3 — 16,2±3,5 мм рт.ст. ЦТР составило в группе 1 — 545,7±14,6 мкм; в группе 2 — 545,3±15,4 мкм; в группе 3 — 544,7±14,6 мкм. Острота зрения составила в группе 1 — 0,93±0,13; в группе 2 — 0,89±0,15; в группе 3 — 0,81±0,18. Среднее ВГД у мужчин — 16,4±3,3 мм рт.ст., у женщин — 16,5±3,3 мм рт.ст. Возраст, острота зрения, ЦТР и ВГД имеют нормальное распределение; ВГД и ЦТР в разных группах достоверно не различаются. Наблюдаемые параметры ни в одном случае значимо не коррелируют друг с другом. Не выявлено разницы в ВГД у мужчин и женщин.ВЫВОДЫ. В здоровой взрослой популяции ЦТР и ВГД имеют нормальное распределение и не претерпевают значимых изменений с возрастом. ВГД не зависит от пола. Среднее ВГД в исследуемой популяции составляет 16,2±3,4 мм рт.ст., средняя ЦТР — 545,3±15,1 мкм
Вакуумная система Ватт-весов: аспекты разработки
This paper considers issues related to the development of the vacuum system of Watt-balance for the newest Russian Federation primary standard of the kilogram. The authors give a list of the necessary data for the development of the vacuum system of the newest Russian Federation kilogram mass standard, relying on the generally accepted methods of vacuum systems calculation. This paper shows the main stages of theoretical and practical research work conducted in D. I. Mendeleyev Institute for Metrology (VNIIM) with the use of the vacuum mass comparator Sartorius CCL 1007from the composition of the state primary measurement standard of mass unit - kilogram GET 3-2020, aimed at developing a vacuum system for the newest standard of the kilogram - Watt-balance. The presented results of the research allow for the development of the vacuum Watt-balancing system.В статье рассматриваются вопросы, связанные с разработкой вакуумной системы Ватт-весов для создаваемого первичного эталона килограмма РФ. Авторы, опираясь на общепринятые методики расчета вакуумных систем, приводят перечень необходимых данных для разработки вакуумной системы создаваемого эталона килограмма РФ. В статье показаны основные этапы теоретических и практических научно-исследовательских работ, проведённых во ФГУП «ВНИИМ им. Д. И. Менделеева» с использованием вакуумного компаратора CCL 1007 из состава государственного первичного эталона единицы массы - килограмма ГЭТ 3-2020, направленных на разработку вакуумной системы создаваемого эталона килограмма — Ватт-весов. Приведены результаты исследований, которые позволяют выполнить разработку вакуумной системы Ватт-весов
Near-IR Emitting Si Nanocrystals Fabricated by Thermal Annealing of SiNx/Si3N4 Multilayers
Silicon nanocrystals in silicon nitride matrix are fabricated by thermal annealing of SiNx/Si3N4 multilayered thin films, and characterized by transmission electron microscopy, X-ray reflectivity and diffraction analysis, photoluminescence and X-ray photoelectron spectroscopy techniques. Si nanocrystals with a mean size of about 4 nm are obtained, and their properties are studied as a function of SiNx layer thickness (1.6–2 nm) and annealing temperature (900–1250 °C). The effect of coalescence of adjacent nanocrystals throughout the Si3N4 barrier layers is observed, which results in formation of distinct ellipsoidal-shaped nanocrystals. Complete intermixing of multilayered film accompanied by an increase of nanocrystal mean size for annealing temperature as high as 1250 °C is shown. Near-IR photoluminescence with the peak at around 1.3–1.4 eV is detected and associated with quantum confined excitons in Si nanocrystals: Photoluminescence maximum is red shifted upon an increase of nanocrystal mean size, while the measured decay time is of order of microsecond. The position of photoluminescence peak as compared to the one for Si nanocrystals in SiO2 matrix is discussed