4,427 research outputs found

    A Pair Polarimeter for Linearly Polarized High Energy Photons

    Get PDF
    A high quality beam of linearly polarized photons of several GeV will become available with the coherent bremsstrahlung technique at JLab. We have developed a polarimeter which requires about two meters of the beam line, has an analyzing power of 20% and an efficiency of 0.02%. The layout and first results of a polarimeter test on the laser back-scattering photon beam at SPring-8/LEPS are presented

    Development of FTK architecture: a fast hardware track trigger for the ATLAS detector

    Full text link
    The Fast Tracker (FTK) is a proposed upgrade to the ATLAS trigger system that will operate at full Level-1 output rates and provide high quality tracks reconstructed over the entire detector by the start of processing in Level-2. FTK solves the combinatorial challenge inherent to tracking by exploiting the massive parallelism of Associative Memories (AM) that can compare inner detector hits to millions of pre-calculated patterns simultaneously. The tracking problem within matched patterns is further simplified by using pre-computed linearized fitting constants and leveraging fast DSP's in modern commercial FPGA's. Overall, FTK is able to compute the helix parameters for all tracks in an event and apply quality cuts in approximately one millisecond. By employing a pipelined architecture, FTK is able to continuously operate at Level-1 rates without deadtime. The system design is defined and studied using ATLAS full simulation. Reconstruction quality is evaluated for single muon events with zero pileup, as well as WH events at the LHC design luminosity. FTK results are compared with the tracking capability of an offline algorithm.Comment: To be published in the proceedings of DPF-2009, Detroit, MI, July 2009, eConf C09072

    The Evolution of FTK, a Real-Time Tracker for Hadron Collider Experiments

    Full text link
    We describe the architecture evolution of the highly-parallel dedicated processor FTK, which is driven by the simulation of LHC events at high luminosity (1034 cm-2 s-1). FTK is able to provide precise on-line track reconstruction for future hadronic collider experiments. The processor, organized in a two-tiered pipelined architecture, execute very fast algorithms based on the use of a large bank of pre-stored patterns of trajectory points (first tier) in combination with full resolution track fitting to refine pattern recognition and to determine off-line quality track parameters. We describe here how the high luminosity simulation results have produced a new organization of the hardware inside the FTK processor core.Comment: 11th ICATPP conferenc

    Effect of ethnicity on access and device complications during endovascular aneurysm repair

    Get PDF
    AbstractIntroductionThere are no published reports on the association between ethnicity and outcome after aortoiliac stent grafting to treat aneurismal disease. Because Hawaii is a state with an ethnically diverse population, we conducted a retrospective study to examine this potential association. We hypothesized that individuals of Asian ancestry may have higher complication rates after endovascular repair compared with non-Asians.MethodsAll endovascular devices placed to treat aneurysm disease from 1996 to 2003 were evaluated in two institutions. The association between ethnicity and access-related and device-related complications, both periprocedural and delayed, was examined with logistic regression analysis.ResultsNinety-two aortoiliac endografts were placed during the study period, including 87 in patients with abdominal aortic aneurysms with or without iliac aneurysm disease, and five patients with isolated iliac artery aneurysms. Forty-four percent of patients were categorized as Asian, 39% as white, 16% as Pacific Islander, and 1% as African American. Access-related and device-related complications (ADRCs) occurred in 11 of 92 (12%) of these patients. The following parameters were significantly associated with ADRCs: Asian ethnicity (P =.015), age greater than 80 years (P = .02), and external iliac diameter smaller than 7.5 mm (P =.01). Asian patients were more likely to have experienced ADRCs than were non-Asian patients (odds ratio, 7.3; 95% confidence interval, 1.5-35.8; P = .015). Asians also had smaller external iliac artery diameters (P = .0003) and more tortuous iliac arteries (P = .03) compared with non-Asians. After adjusting for iliac artery diameter and tortuosity, the association between Asian ethnicity and ARDCs became nonsignificant (P = .074), which suggests that the association between race and complications may be at least in part due to small and tortuous iliac arteries. There was no association between age, gender, or ethnicity and postoperative detection of endoleak.ConclusionOur data indicate that individuals of Asian ancestry are far more likely to experience adverse access-related and device-related complications after aortoiliac stent grafting than are non-Asians. We found that this association is at least partly attributable to the smaller and more tortuous iliac arteries in persons of Asian ancestry

    Near-threshold Lambda(1520) production by the gamma p -> K+Lambda(1520) reaction at forward K+ angles

    Full text link
    Differential cross sections and photon-beam asymmetries for the gamma p -> K+ Lambda(1520) reaction have been measured with linearly polarized photon beams at energies from the threshold to 2.4 GeV at 0.6<cos(theta)<1. A new bump structure was found at W=2.11 GeV in the cross sections. The bump is not well reproduced by theoretical calculations introducing a nucleon resonance with J<=3/2. This result suggests that the bump might be produced by a nucleon resonance possibly with J>=5/2 or by a new reaction process, for example an interference effect with the phi photoproduction having a similar bump structure in the cross sections.Comment: 5 pages, 4 figures, published in Phys. Rev. Let

    Measurement of the γ⃗p→K+Λ\vec{\gamma} p \to K^+ \Lambda Reaction at Backward Angles

    Full text link
    Cross sections for the γp→K+Λ\gamma p \to K^+ \Lambda have been measured at backward angles using linearly polarized photons in the range 1.50 to 2.37 GeV. In addition, the beam asymmetry for this reaction has been measured for the first time at backward angles. The Λ\Lambda was detected at forward angles in the LEPS spectrometer via its decay to pπ−p\pi^- and the K^+ was inferred using the technique of missing mass. These measurements, corresponding to kaons at far backward angles in the center-of-mass frame, complement similar CLAS data at other angles. Comparison with theoretical models shows that the reactions in these kinematics provide further opportunities to investigate the reaction mechanisms of hadron dynamics.Comment: 6 figures, submitted to PRC rapid communication

    Backward-angle photoproduction of π0\pi^0 mesons on the proton at EγE_\gamma = 1.5--2.4 GeV

    Full text link
    Differential cross sections and photon beam asymmetries for π0\pi^0 photoproduction have been measured at EγE_\gamma = 1.5--2.4 GeV and at the π0\pi^0 scattering angles, --1 << cosΘc.m.<\Theta_{c.m.} < --0.6. The energy-dependent slope of differential cross sections for uu-channel π0\pi^0 production has been determined. An enhancement at backward angles is found above EγE_\gamma = 2.0 GeV. This is inferred to be due to the uu-channel contribution and/or resonances. Photon beam asymmetries have been obtained for the first time at backward angles. A strong angular dependence has been found at Eγ>E_\gamma > 2.0 GeV, which may be due to the unknown high-mass resonances.Comment: 12 pages, 4 figures, submitted to PL
    • …
    corecore