67 research outputs found

    Novel frequency chirp compensation scheme for directly modulated SG DBR tunable lasers

    Get PDF
    The authors demonstrate a compensation scheme to reduce the frequency chirp associated with directly modulated sampled grating distributed Bragg reflector tunable lasers. Experimental results obtained show that the direct modulation of the laser's gain section results in a large frequency chirp of 25 GHz. However, by simultaneous modulation of the laser's phase section this large frequency chirp can be significantly reduced

    Low-mass dark matter search results from full exposure of PandaX-I experiment

    Full text link
    We report the results of a weakly-interacting massive particle (WIMP) dark matter search using the full 80.1\;live-day exposure of the first stage of the PandaX experiment (PandaX-I) located in the China Jin-Ping Underground Laboratory. The PandaX-I detector has been optimized for detecting low-mass WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid xenon target mass of 54.0\,kg, no significant excess event were found above the expected background. A profile likelihood analysis confirms our earlier finding that the PandaX-I data disfavor all positive low-mass WIMP signals reported in the literature under standard assumptions. A stringent bound on the low mass WIMP is set at WIMP mass below 10\,GeV/c2^2, demonstrating that liquid xenon detectors can be competitive for low-mass WIMP searches.Comment: v3 as accepted by PRD. Minor update in the text in response to referee comments. Separating Fig. 11(a) and (b) into Fig. 11 and Fig. 12. Legend tweak in Fig. 9(b) and 9(c) as suggested by referee, as well as a missing legend for CRESST-II legend in Fig. 12 (now Fig. 13). Same version as submitted to PR

    Effects of Pulsed Magnetic Field Melt Treatment on Grain Refinement of Al-Si-Mg-Cu-Ni Alloy Direct-Chill Casting Billet

    No full text
    Al-Si-Mg-Cu-Ni alloy is widely used in the manufacture of high-performance car engine parts. Coarse, dendritic α-Al and large primary Si are common in Al-Si-Mg-Cu-Ni alloy DC casting billet, which is harmful to the performance of the final product. In this paper, a pulsed magnetic field melt treatment technique was applied to the melt in the launder of a DC casting platform to modify the α-Al and primary Si in the billet. A transient numerical model was established to analyze the electromagnetic field, flow field and temperature field in the melt during the pulsed magnetic field treatment. The effect of the magnetic energy on the clusters in the melt was analyzed. We found that during the pulsed magnetic field melt treatment, the number of clusters close to the critical size was increased due to the cluster formation work being reduced by the magnetic energy, which facilitated nucleation and refined the solidification structure. Furthermore, the flow velocity increased, and temperature homogenized in the melt during the pulsed magnetic field melt treatment, which benefitted the clusters close to the critical size distributed and maintained in the melt uniformly. The experimental results show that the α-Al and primary Si were small and homogeneous following the pulsed magnetic field melt treatment. The size of α-Al and primary Si was reduced by 25.6–44.4% and 32.2–54.1%, respectively, in the billet center compared to the conventional process

    Quantification of Paeoniflorin by Fully Validated LC–MS/MS Method: Its Application to Pharmacokinetic Interaction between Paeoniflorin and Verapamil

    No full text
    A rapid, sensitive, and specific LC-MS/MS method was developed and fully validated for the detection of paeoniflorin only in rat plasma, and applied to pharmacokinetic studies, including intravenous, multi-dose oral and combined administrations with verapamil. In this study, tolbutamide was used as the internal standard, and the protein precipitation extraction method, using acetonitrile as the extraction agent, was used for the sample preparation. Subsequently, the supernatant samples were analyzed on a Phenomenex Gemini® NX-C18 column with a flow rate of 1.0 mL/min in a gradient elution procedure. In the extracted rat plasma, the method exhibited high sensitivity (LLOQ of 1.0 ng/mL) upon selecting ammonium adduct ions ([M+NH4]+) as the precursor ions and good linearity over the concentration range of 1.0–2000 ng/mL, with correlation coefficients >0.99. The intra- and inter-batch accuracy RE% values were within ±8.2%, and the precision RSD% values were ≤8.1% and ≤10.0%, respectively. The results show that the method can be successfully applied to quantitate paeoniflorin in biological samples. Additionally, paeoniflorin is subsequently confirmed to be the substrate of the P-gp transporter in vivo and in vitro for the first time, which would be necessary and beneficial to investigate the clinical safety and efficacy of PF with other drugs in the treatment of rheumatoid arthritis
    corecore