19 research outputs found

    Using computing models from particle physics to investigate dose-toxicity correlations in cancer radiotherapy

    Get PDF
    © Published under licence by IOP Publishing Ltd. A system has been developed to provide flexible, efficient and robust processing of radiotherapy planning and treatment data collected in the VoxTox project, which investigates differences between planned and delivered dose, and dose-toxicity correlations. This paper outlines the system requirements and implementation, highlighting the use made of software tools and computing models developed for experiments at the Large Hadron Collider. Experience with VoxTox data processing is summarised

    Automatic contour propagation using deformable image registration to determine delivered dose to spinal cord in head-and-neck cancer radiotherapy.

    Get PDF
    To determine delivered dose to the spinal cord, a technique has been developed to propagate manual contours from kilovoltage computed-tomography (kVCT) scans for treatment planning to megavoltage computed-tomography (MVCT) guidance scans. The technique uses the Elastix software to perform intensity-based deformable image registration of each kVCT scan to the associated MVCT scans. The registration transform is then applied to contours of the spinal cord drawn manually on the kVCT scan, to obtain contour positions on the MVCT scans. Different registration strategies have been investigated, with performance evaluated by comparing the resulting auto-contours with manual contours, drawn by oncologists. The comparison metrics include the conformity index (CI), and the distance between centres (DBC). With optimised registration, auto-contours generally agree well with manual contours. Considering all 30 MVCT scans for each of three patients, the median CI is [Formula: see text], and the median DBC is ([Formula: see text]) mm. An intra-observer comparison for the same scans gives a median CI of [Formula: see text] and a DBC of ([Formula: see text]) mm. Good levels of conformity are also obtained when auto-contours are compared with manual contours from one observer for a single MVCT scan for each of 30 patients, and when they are compared with manual contours from six observers for two MVCT scans for each of three patients. Using the auto-contours to estimate organ position at treatment time, a preliminary study of 33 patients who underwent radiotherapy for head-and-neck cancers indicates good agreement between planned and delivered dose to the spinal cord.CRUK, Singapore Government, Addenbrooke's Charitable Trust, Cambridge Biomedical Research Centr

    Applying physical science techniques and CERN technology to an unsolved problem in radiation treatment for cancer: the multidisciplinary ‘VoxTox’ research programme

    Get PDF
    The VoxTox research programme has applied expertise from the physical sciences to the problem of radiotherapy toxicity, bringing together expertise from engineering, mathematics, high energy physics (including the Large Hadron Collider), medical physics and radiation oncology. In our initial cohort of 109 men treated with curative radiotherapy for prostate cancer, daily image guidance computed tomography (CT) scans have been used to calculate delivered dose to the rectum, as distinct from planned dose, using an automated approach. Clinical toxicity data have been collected, allowing us to address the hypothesis that delivered dose provides a better predictor of toxicity than planned dose.JES was supported by Cancer Research UK through the Cambridge Cancer Centre. NGB, ASP and MG are supported by the National Institute of Health Research Cambridge Biomedical Research Centre. KH, MR AMB, EW and SJB were supported by the VoxTox Research Programme, funded by Cancer Research UK. DJN is supported by Addenbrooke’s Charitable Trust and Cancer Research UK through the Cambridge Cancer Centre. FMB was supported by the Science and Technology Facilities Council. MPDS was part supported by the VoxTox Research Programme, funded by Cancer Research UK. RJ was part supported by the VoxTox Research Programme, funded by Cancer Research UK. LS is supported by the Armstrong Trust. XC was supported by the Isaac Newton Trust. CBS acknowledges support from the EPSRC Centre for Mathematical and Statistical Analysis of Multimodal Clinical Imaging, the Leverhulme Trust, the EU-RISE project CHiPS and the Cantab Capital Institute for the Mathematics of Information. NT was supported by a Gates-Cambridge Scholarship, funded by the Bill and Melinda Gates Foundation, PLY and SYKS by the Singapore Government

    Automatic contour propagation using deformable image registration to determine delivered dose to spinal cord in head-and-neck cancer radiotherapy.

    No full text
    To determine delivered dose to the spinal cord, a technique has been developed to propagate manual contours from kilovoltage computed-tomography (kVCT) scans for treatment planning to megavoltage computed-tomography (MVCT) guidance scans. The technique uses the Elastix software to perform intensity-based deformable image registration of each kVCT scan to the associated MVCT scans. The registration transform is then applied to contours of the spinal cord drawn manually on the kVCT scan, to obtain contour positions on the MVCT scans. Different registration strategies have been investigated, with performance evaluated by comparing the resulting auto-contours with manual contours, drawn by oncologists. The comparison metrics include the conformity index (CI), and the distance between centres (DBC). With optimised registration, auto-contours generally agree well with manual contours. Considering all 30 MVCT scans for each of three patients, the median CI is [Formula: see text], and the median DBC is ([Formula: see text]) mm. An intra-observer comparison for the same scans gives a median CI of [Formula: see text] and a DBC of ([Formula: see text]) mm. Good levels of conformity are also obtained when auto-contours are compared with manual contours from one observer for a single MVCT scan for each of 30 patients, and when they are compared with manual contours from six observers for two MVCT scans for each of three patients. Using the auto-contours to estimate organ position at treatment time, a preliminary study of 33 patients who underwent radiotherapy for head-and-neck cancers indicates good agreement between planned and delivered dose to the spinal cord

    Anatomical change during radiotherapy for head and neck cancer, and its effect on delivered dose to the spinal cord.

    No full text
    BACKGROUND AND PURPOSE: The impact of weight loss and anatomical change during head and neck (H&N) radiotherapy on spinal cord dosimetry is poorly understood, limiting evidence-based adaptive management strategies. MATERIALS AND METHODS: 133 H&N patients treated with daily mega-voltage CT image-guidance (MVCT-IG) on TomoTherapy, were selected. Elastix software was used to deform planning scan SC contours to MVCT-IG scans, and accumulate dose. Planned (DP) and delivered (DA) spinal cord D2% (SCD2%) were compared. Univariate relationships between neck irradiation strategy (unilateral vs bilateral), T-stage, N-stage, weight loss, and changes in lateral separation (LND) and CT slice surface area (SSA) at C1 and the superior thyroid notch (TN), and ΔSCD2% [(DA - DP) D2%] were examined. RESULTS: The mean value for (DA - DP) D2% was -0.07 Gy (95%CI -0.28 to 0.14, range -5.7 Gy to 3.8 Gy), and the mean absolute difference between DP and DA (independent of difference direction) was 0.9 Gy (95%CI 0.76-1.04 Gy). Neck treatment strategy (p = 0.39) and T-stage (p = 0.56) did not affect ΔSCD2%. Borderline significance (p = 0.09) was seen for higher N-stage (N2-3) and higher ΔSCD2%. Mean reductions in anatomical metrics were substantial: weight loss 6.8 kg; C1LND 12.9 mm; C1SSA 12.1 cm2; TNLND 5.3 mm; TNSSA 11.2 cm2, but no relationship between weight loss or anatomical change and ΔSCD2% was observed (all r2 < 0.1). CONCLUSIONS: Differences between delivered and planned spinal cord D2% are small in patients treated with daily IG. Even patients experiencing substantial weight loss or anatomical change during treatment do not require adaptive replanning for spinal cord safety.- The VoxTox project received a 5-year programme grant from Cancer Research UK (CRUK) (Ref: C8857/A13405). - KH, MR and AMB were supported by the programme grant. - DJN is supported by a CRUK Clinical Research Fellowship (Ref: C20/A20917). - PLY and SYKS were supported by the Singapore Government. - LEAS is supported by the University of Cambridge W D Armstrong Trust Fund. - NGB was supported by the NIHR Cambridge Biomedical Research Centre

    Applying physical science techniques and CERN technology to an unsolved problem in radiation treatment for cancer: the multidisciplinary ‘VoxTox’ research programme

    No full text
    The VoxTox research programme has applied expertise from the physical sciences to the problem of radiotherapy toxicity, bringing together expertise from engineering, mathematics, high energy physics (including the Large Hadron Collider), medical physics and radiation oncology. In our initial cohort of 109 men treated with curative radiotherapy for prostate cancer, daily image guidance computed tomography (CT) scans have been used to calculate delivered dose to the rectum, as distinct from planned dose, using an automated approach. Clinical toxicity data have been collected, allowing us to address the hypothesis that delivered dose provides a better predictor of toxicity than planned dose
    corecore