6 research outputs found

    Chest wall systemic artery-to-pulmonary artery vascular malformation treated by embolization of feeders and drainers: A case report

    No full text
    A 74-year-old woman presented with progressive dyspnea. Computed tomography revealed a large systemic artery-to-pulmonary artery vascular malformation (VM) on the right chest wall. Embolization of the VM was performed. First, the main drainers of the VM were retrogradely selected from the segmental pulmonary arteries and embolized using microcoils. Second, 2 main feeders of the VM were selected and embolized with N-butyl cyanoacrylate. Thus, marked flow reduction in the VM was achieved, and the patient's symptom improved dramatically. We believe that embolization of both feeders and drainers is an effective technique for treatment of a chest wall systemic artery-to-pulmonary artery VM

    Transcatheter arterial embolization of a type 2 endoleak through the dorsal pancreatic artery after the hybrid repair of a thoracoabdominal aortic aneurysm: A case report

    No full text
    An 83-year-old woman with a history of hybrid repair of thoracoabdominal aortic aneurysm presented with enlargement of the aneurysm due to a type 2 endoleak from the celiac artery. The endoleak cavity was accessed via the dorsal pancreatic artery, and embolization using N-butyl cyanoacrylate and coils was successfully performed. When celiac artery branches are embolized during hybrid repair of a thoracoabdominal aortic aneurysm, attention should be paid to the dorsal pancreatic artery to appropriately determine which branches are to be embolized, because a nonembolized dorsal pancreatic artery may lead to type 2 endoleaks

    Placement of a Viabahn stent-graft for hepatic artery pseudoaneurysm complicated by arterial dissection caused by a guiding sheath

    No full text
    A 69-year-old man was transferred to our hospital for massive hemorrhage from a right hepatic artery pseudoaneurysm 5 months after surgery for gastric cancer. Stent-graft placement was planned to avoid fatal hepatic infarction, and a guiding sheath was advanced deeply into the tortuous and stenotic right hepatic artery beyond the pseudoaneurysm for safe deployment of a stent-graft. However, this advancement caused arterial dissection of the right hepatic artery. After the guiding sheath was pulled back, a Viabahn stent-graft was successfully advanced over a guidewire to exclude the pseudoaneurysm. We consider that a Viabahn stent-graft is more flexible than a guiding sheath and that advancing a Viabahn stent-graft directly from a proximally placed guiding sheath is safer than advancing a guiding sheath into a tortuous and stenotic abdominal artery. Keywords: Stent-graft, Pseudoaneurysm, Arterial dissectio

    Usefulness of a distal access catheter in embolization of a short gastric artery pseudoaneurysm

    No full text
    A 59-year-old man was admitted to our hospital for hematemesis. A hematoma was found in the posterior wall of the stomach, but the source of bleeding was not identified. One month later, contrast-enhanced computed tomography revealed a pseudoaneurysm in the short gastric artery. Embolization of the pseudoaneurysm was difficult due to vessel tortuosity. Usage of a distal access catheter improved catheter stability and enabled successful embolization. We consider a distal access catheter to be useful for embolization of an aneurysm beyond a tortuous artery. Keywords: Short gastric artery, Pseudoaneurysm, Embolization, Distal access cathete

    Loop formation by an aortic occlusion balloon catheter during resuscitative endovascular balloon occlusion of the aorta (REBOA)

    No full text
    A 77-year-old man was transferred to our hospital for endoscopically uncontrollable active bleeding from a duodenal ulcer. Soon after his arrival, he became hemodynamically unstable and resuscitative endovascular balloon occlusion of the aorta was performed using a 7-F aortic occlusion balloon catheter (Rescue Balloon; Tokai Medical Products, Aichi, Japan). He became hemodynamically stable and was transferred to the CT room. CT demonstrated that the distal part of the catheter shaft had made a loop in the aorta and the balloon was located at the level of the upper abdomen. We consider the low-profile occlusion balloon catheter to be less rigid than large ones, and care should be taken to prevent balloon migration and catheter shaft bending. Keywords: Resuscitative endovascular balloon occlusion of the aorta, Aortic occlusion balloon cathete

    Successful embolization of ileal conduit stomal varices with N-butyl cyanoacrylate via a recanalized paraumbilical vein

    No full text
    A 77-year-old woman with liver cirrhosis was admitted to our hospital for marked hemorrhage in her ileal conduit stoma. She had a history of cystectomy and urinary diversion for bladder carcinoma 2 years ago. Contrast-enhanced CT demonstrated varices in the ileal conduit stoma. We accessed the varices via a recanalized paraumbilical vein to avoid pain from the transhepatic approach, and selectively embolized the varices with N-butyl cyanoacrylate (NBCA). We consider antegrade embolization of ileal conduit stomal varices with NBCA to be effective and feasible. Access via a paraumbilical vein is a useful alternative to the transhepatic approach. Keywords: Ectopic varix, Portal hypertension, Embolization, N-butyl cyanoacrylate, Paraumbilical vei
    corecore