191 research outputs found
Fiber-Optic Micro-Probes for Measuring Acidity Level, Temperature, and Antigens
A pH micro-probe, a temperature micro-probe, and an immuno-based micro-probe each include a shaft for transmuting an input light signal and a tip for inserting into a cell or other substance for measuring pH, temperature, and/or antigens. The pH micro-probe and the temperature micro-probe each include a luminescent material positioned on the tip of the micro-probe. The light signal excites the luminescent material so that the luminescent material emits a luminescent light signal. The luminescent light signal has a property value dependent on the pH or temperature being measured and reflects back through the shaft for being measured by a light signal measuring device. The immuno-based micro-probe includes a reflective material that has an effective refractive index dependent on the number of antigen-antibody bonds present on the reflective material
Corrigendum to “A Fractional Trust Region Method for Linear Equality Constrained Optimization”
A quasi-Newton trust region method with a new fractional model for linearly constrained optimization problems is proposed. We delete linear equality constraints by using null space technique. The fractional trust region subproblem is solved by a simple dogleg method. The global convergence of the proposed algorithm is established and proved. Numerical results for test problems show the efficiency of the trust region method with new fractional model. These results give the base of further research on nonlinear optimization
Highly Sensitive Electrochemical Sensor for the Determination of 8-Hydroxy-2 \u27-deoxyguanosine Incorporating SWCNTs-Nafion Composite Film
8-Hydroxy-2\u27-deoxyguanosine (8-OHdG) is a typical biomarker of oxidative DNA damage and has attracted much attention in recent years since the level of 8-OHdG in body fluids is typically associated with various diseases. In this work, a simple and highly sensitive electrochemical sensor for the determination of 8-OHdG was fabricated incorporating single wall carbon nanotubes-(SWCNTs-) Nafion composite film coated on glassy carbon electrode. Nafion was chosen as an optimal adhesive agent from a series of adhesive agents and acted as a binder, enrichment, and exclusion film. Due to the strong cation-exchange ability of Nafion and the outstanding electronic properties ofSWCNTs, the prepared SWCNTs-Nafion film can strongly enhance the electrochemical response to oxidation of 8-OHdG and efficiently alleviate the interferences from uric acid and ascorbic acid. The oxidation peak currents are linear with the concentration of 8-OHdG in the range of 0.03 to 1.25 mu M with a detection limit of 8.0 nM (S/N = 3). This work demonstrates that SWCNTs-Nafion film can improve the sensitivity, selectivity, reproducibility, and stability, making it an ideal candidate for electrochemical detection of 8-OHdG
Enhanced Flocculation using Drinking Water Treatment Plant Sedimentation Residual Solids
Inefficient removal of total organic carbon (TOC) leads to the formation of carcinogenic disinfection by-products (DBPs) when a disinfectant is added. This study is performed in an effort to develop a simple, non-invasive, and cost-effective technology that will effectively lower organic precursors by having water utilities reuse their treatment residual solids. Jar tests are used to simulate drinking water treatment processes with coagulants-aluminum sulfate (alum), poly-aluminum chloride (PACl), and ferric chloride and their residual solids. Ten coagulant-to-residual (C/R) ratios are tested with water from the Missouri River at Coopers Landing in Columbia, MO versus alluvial ground waters. This treatment results in heavier floc formation and leads to improved sedimentation of organics and additional removal of aluminum and iron. An average of 21%, 28%, and 33% additional TOC removal can be achieved with C/R ratios \u3c 1 with alum, PACl, and ferric chloride, respectively
Up-regulation of CNDP2 facilitates the proliferation of colon cancer
BACKGROUND: Cytosolic nonspecific dipetidase (CN2) belongs to the family of M20 metallopeptidases. It was stated in previous articles that higher expression levels of CN2 were observed in renal cell carcinoma and breast cancer. Our study explored the correlation between CN2 and colon carcinogenesis. METHODS: We analysed the relationship between 183 patients clinicopathological characteristics and its CN2 expression. To detect the levels of CN2 in colon cancer cell lines and colon cancer tissues by western blot. To verify cell proliferation in colon cancer cells with knockdown of CNDP2 and explore the causes of these phenomena. RESULTS: The expression levels of CN2 in clinical colon tumors and colon cancer cell lines were significantly higher than that in normal colon mucosa and colon cell lines. The difference in CN2 levels was associated with tumor location (right- and left-sided colon cancer), but there was no significant association with age, gender, tumor size, tumor grade, tumor stage or serum carcinoembryonic antigen (CEA). Knockdown of CNDP2 inhibited cell proliferation, blocked cell cycle progression and retarded carcinogenesis in an animal model. The signaling pathway through which knockdown of CNDP2 inhibited cell proliferation and tumorigenesis involved in EGFR, cyclin B1 and cyclin E. CONCLUSIONS: Knockdown of CNDP2 can inhibit the proliferation of colon cancer in vitro and retarded carcinogenesis in vivo
Study Of Legionella Pneumophila Treatment With Copper In Drinking Water By Single Cell-ICP-MS
Legionella pneumophila is a persistent opportunistic pathogen that poses a significant threat to domestic water systems. Previous studies suggest that copper (Cu) is an effective antimicrobial in water systems. A rapid and sensitive quantification method is desired to optimize the conditions of L. pneumophila treatment by Cu and to better understand the interaction mechanisms between Cu and cells. In this study, we developed a highly sensitive single cell (SC)-ICP-MS method to monitor L. pneumophila cell concentration and track their uptake of Cu. The SC-ICP-MS method showed excellent sensitivity (with a cell concentration detection limit of 1000 cells/mL), accuracy (good agreement with conventional hemocytometry method), and precision (relative standard deviation \u3c 5%) in drinking water matrix. The cupric ions (Cu2+) treatment results indicated that the total L. pneumophila cell concentration, Cu mass per cell, colony-forming unit counting, and Cu concentration in supernatant all exhibited a dose-dependent trend, with 800–1200 µg/L reaching high disinfection rates in drinking water. The investigation of percentages of viable and culturable, viable but nonculturable (VBNC), and lysed cells suggested there always were VBNC present at any Cu concentration. Experimental results of different Cu2+ treatment times further suggested that L. pneumophila cells developed an antimicrobial resistant mechanism with the prolonged Cu exposure. This is the first quantification study on the interactions of Cu and L. pneumophila in drinking water using SC-ICP-MS. Graphical abstract: [Figure not available: see fulltext.
Selected trace element uptake by rice grain as affected by soil arsenic, water management and cultivar -a field investigation
Accumulation of arsenic (As) in rice grain was reported in many regions of the world, including the United States, which has been a threat to human health. This field research investigated the grain As accumulation and its relationship with the uptake of selenium (Se), molybdenum (Mo), and cadmium (Cd) in soils with and without monosodium methanearsonate (MSMA) amended, as effects of selected rice cultivars and water management. Results indicated that MSMA increased the accumulation of As and Se but decreased Mo for all six cultivars under four irrigation management. MSMA also increased grain-Cd in some cultivars. In no MSMA-amended soil (Native soil), intermittent flooding decreased grain-As by 66%, grain-Se by 21%, and grain-Mo by 63%, but increased grain-Cd by 64% in Zhe 733, a straighthead resistant cultivar, while in MSMA-amended soil, intermittent flooding decreased grain-As by 63% and grain-Mo by 44% but increased grain-Se by 68% and grain-Cd by three times. For all other five cultivars, intermittent flooding generally decreased grain-As and grain-Mo but increased grain-Se and grain-Cd. Zhe 733 cultivar resulted in the lowest grain concentrations of all trace elements in all water treatments. A negative grain As-Se correlation and a positive grain As-Mo correlation were significant but not the As-Cd correlation. This research showed that the uptake of As, Se, Mo, and Cd by rice grain occurred as a complex function of multiple variables, including cultivar type and soil chemistry. As a result, accumulation of As and other trace elements in rice grain may be controlled by selecting appropriate cultivars and adopting appropriate water management practices
- …