46 research outputs found

    Improvement of the target sensitivity in DECIGO by optimizing its parameters for quantum noise including the effect of diffraction loss

    Full text link
    DECIGO is the future Japanese gravitational wave detector in outer space. We previously set the default design parameters to provide a good target sensitivity to detect the primordial gravitational waves (GWs). However, the updated upper limit of the primordial GWs by the Planck observations motivated us for further optimization of the target sensitivity. Previously, we had not considered optical diffraction loss due to the very long cavity length. In this paper, we optimize various DECIGO parameters by maximizing the signal-to-noise ratio (SNR), for the primordial GWs to quantum noise including the effects of diffraction loss. We evaluated the power spectrum density for one cluster in DECIGO utilizing the quantum noise of one differential Fabry-Perot interferometer. Then we calculated the SNR by correlating two clusters in the same position. We performed the optimization for two cases: the constant mirror-thickness case and the constant mirror-mass case. As a result, we obtained the SNR dependence on the mirror radius, which also determines various DECIGO parameters. This result is the first step toward optimizing the DECIGO design by considering the practical constraints on the mirror dimension and implementing other noise sources.Comment: 13 pages, 12 figure

    First-step experiment in developing optical-spring quantum locking for DECIGO: sensitivity optimization for simulated quantum noise by completing the square

    Full text link
    DECi-hertz Interferometer Gravitational Wave Observatory (DECIGO) is a future mission for a space-borne laser interferometer. DECIGO has 1,000-km-long arm cavities mainly to detect the primordial gravitational waves (PGW) at lower frequencies around 0.1 Hz. Observations in the electromagnetic spectrum have lowered the bounds on the upper limit of PGW energy density (Ωgw10151016\Omega_{\rm gw} \sim 10^{-15} \to 10^{-16}). As a result, DECIGO's target sensitivity, which is mainly limited by quantum noise, needs further improvement. To maximize the feasibility of detection while constrained by DECIGO's large diffraction loss, a quantum locking technique with an optical spring was theoretically proposed to improve the signal-to-noise ratio of the PGW. In this paper, we experimentally verify one key element of the optical-spring quantum locking: sensitivity optimization by completing the square of multiple detector outputs. This experiment is operated on a simplified tabletop optical setup with classical noise simulating quantum noise. We succeed in getting the best of the sensitivities with two different laser powers by the square completion method.Comment: 10 pages, 14 figure

    The Development and Assessment on the Social Studies Handbook for Supporting Teacher’s Lesson Planning and Improvement : A Content Structure of Handbook which can be Applied to Pre-service and In-service Teacher Education

    Get PDF
    The purposes of this paper are to develop the draft of handbook for planning, teaching and accessing the class of social studies and evaluate effects of the handbook for teacher training and their professional development. The structure of the first draft was designed based on Kolb’s learning theory. The present results suggested that the usefulness of the contents structure was perceived by (1) pre-service teachers and (2) in-service teachers, and the possibility for application was also recognized by the teacher educator as (3) university professor who teach methods courses, (4) senior supervisor who is in charge of designing the professional development programs and (5) younger supervisor who is in charge of tutoring the novice teacher, but they illustrated their different types of the significances, limits and utilization according to their purposes and as well as their responsibility. The authors implicated the alterative design of the handbook based on Korthagen’s reflective learning model for meeting their purposes and solving the structural problems inherit in the handbook

    Different prognostic outcomes in two cases of FDG-PET/CT-Positive and -negative cardiac angiosarcoma

    Get PDF
    Cardiac angiosarcoma is a rare malignant tumor with a poor prognosis, characterized by the high uptake of 18F-fluorodeoxyglucose (FDG). This case report presents two cases of cardiac angiosarcoma with a marked difference in FDG uptake and prognosis.Case Summary:Case 1: A 40-year-old male presented with syncope. Ultrasound echocardiography demonstrated a cardiac tumor with a high uptake of 18F-FDG (maximum standardized uptake value=9.2). The patient underwent heart catheterization and tumor biopsy. The pathological result was high-grade angiosarcoma, and the MIB-1(Ki-67) proliferation index was approximately 20%. Systemic chemotherapy was administered; however, the patient died 2 years and 5 months after disease onset.Case 2: A 65-year-old female had a right atrial tumor incidentally diagnosed during routine ultrasound echocardiography. The tumor exhibited a low uptake of 18F-FDG (maximum standardized uptake value=1.8). Open heart surgery was performed, and the tumor was completely resected. Histological analysis revealed low-grade angiosarcoma, and the MIB-1(Ki-67) proliferation index was less than 5%. The patient was followed-up and had not relapsed 2 years after surgery.Conclusion: 18F-FDG uptake may reflect pathological tumor grade and prognosis in cardiac angiosarcoma

    Focal dose escalation using FDG-PET-guided intensity-modulated radiation therapy boost for postoperative local recurrent rectal cancer: a planning study with comparison of DVH and NTCP

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To evaluate the safety of focal dose escalation to regions with standardized uptake value (SUV) >2.0 using intensity-modulated radiation therapy (IMRT) by comparison of radiotherapy plans using dose-volume histograms (DVHs) and normal tissue complication probability (NTCP) for postoperative local recurrent rectal cancer</p> <p>Methods</p> <p>First, we performed conventional radiotherapy with 40 Gy/20 fr. (CRT 40 Gy) for 12 patients with postoperative local recurrent rectal cancer, and then we performed FDG-PET/CT radiotherapy planning for those patients. We defined the regions with SUV > 2.0 as biological target volume (BTV) and made three boost plans for each patient: 1) CRT boost plan, 2) IMRT without dose-painting boost plan, and 3) IMRT with dose-painting boost plan. The total boost dose was 20 Gy. In IMRT with dose-painting boost plan, we increased the dose for BTV+5 mm by 30% of the prescribed dose. We added CRT boost plan to CRT 40 Gy (<it>summed plan 1</it>), IMRT without dose-painting boost plan to CRT 40 Gy (<it>summed plan 2</it>) and IMRT with dose-painting boost plan to CRT 40 Gy (<it>summed plan 3</it>), and we compared those plans using DVHs and NTCP.</p> <p>Results</p> <p>D<sub>mean </sub>of PTV-PET and that of PTV-CT were 26.5 Gy and 21.3 Gy, respectively. V<sub>50 </sub>of small bowel PRV in <it>summed plan 1 </it>was significantly higher than those in other plans ((<it>summed plan 1 </it>vs. <it>summed plan 2 </it>vs. <it>summed plan 3</it>: 47.11 ± 45.33 cm<sup>3 </sup>vs. 40.63 ± 39.13 cm<sup>3 </sup>vs. 41.25 ± 39.96 cm<sup>3</sup>(p < 0.01, respectively)). There were no significant differences in V<sub>30</sub>, V<sub>40</sub>, V<sub>60</sub>, D<sub>mean </sub>or NTCP of small bowel PRV.</p> <p>Conclusions</p> <p>FDG-PET-guided IMRT can facilitate focal dose-escalation to regions with SUV above 2.0 for postoperative local recurrent rectal cancer.</p
    corecore