37 research outputs found

    Active Specific Immunotherapy in the Management of Adenocarcinoma of the Pancreas

    Get PDF
    Active specific immunotherapy for pancreatic adenocarcinoma and subsequent immunohistochemical analysis of tumour tissue have not been previously reported. To date, the therapy of pancreatic adenocarcinoma has been largely unsuccessful. A patient treated with a therapeutic ‘cancer vaccine’ and the immunological impact on the primary tumour of this potential new therapy are described. To the authors’ knowledge, this is both the first patient to be treated with active specific immunotherapy for pancreatic adenocarcinoma and the first to be studied immunologically by flow cytometry and immunohistochemistry with an apparent positive clinical impact

    Tight junctions and the modulation of barrier function in disease

    Get PDF
    Tight junctions create a paracellular barrier in epithelial and endothelial cells protecting them from the external environment. Two different classes of integral membrane proteins constitute the tight junction strands in epithelial cells and endothelial cells, occludin and members of the claudin protein family. In addition, cytoplasmic scaffolding molecules associated with these junctions regulate diverse physiological processes like proliferation, cell polarity and regulated diffusion. In many diseases, disruption of this regulated barrier occurs. This review will briefly describe the molecular composition of the tight junctions and then present evidence of the link between tight junction dysfunction and disease

    The Impact of Clinical Information on the Assessment of Endoscopic Activity: Characteristics of the Ulcerative Colitis Endoscopic Index Of Severity [UCEIS].

    No full text
    BACKGROUND AND AIMS: To determine whether clinical information influences endoscopic scoring by central readers using the Ulcerative Colitis Endoscopic Index of Severity [UCEIS; comprising 'vascular pattern', 'bleeding', 'erosions and ulcers']. METHODS: Forty central readers performed 28 evaluations, including 2 repeats, from a library of 44 video sigmoidoscopies stratified by Mayo Clinic Score. Following training, readers were randomised to scoring with ['unblinded', n = 20, including 4 control videos with misleading information] or without ['blinded', n 20] clinical information. A total of 21 virtual Central Reader Groups [CRGs], of three blinded readers, were created. Agreement criteria were pre-specified. Kappa [κ] statistics quantified intra- and inter-reader variability. RESULTS: Mean UCEIS scores did not differ between blinded and unblinded readers for any of the 40 main videos. UCEIS standard deviations [SD] were similar [median blinded 0.94, unblinded 0.93; p = 0.97]. Correlation between UCEIS and visual analogue scale [VAS] assessment of overall severity was high [r blinded = 0.90, unblinded = 0.93; p = 0.02]. Scores for control videos were similar [UCEIS: p ≥ 0.55; VAS: p ≥ 0.07]. Intra- [κ 0.47-0.74] and inter-reader [κ 0.40-0.53] variability for items and full UCEIS was 'moderate'-to-'substantial', with no significant differences except for intra-reader variability for erosions and ulcers [κ blinded: 0.47 vs unblinded: 0.74; p 0.047]. The SD of CRGs was lower than for individual central readers [0.54 vs 0.95; p < 0.001]. Correlation between blinded UCEIS and patient-reported symptoms was high [stool frequency: 0.76; rectal bleeding: 0.82; both: 0.81]. CONCLUSIONS: The UCEIS is minimally affected by knowledge of clinical details, strongly correlates with patient-reported symptoms, and is a suitable instrument for trials. CRGs performed better than individuals

    Reliability and initial validation of the ulcerative colitis endoscopic index of severity.

    No full text
    BACKGROUND and AIMS: We studied the reliability of the previously described Ulcerative Colitis Endoscopic Index of Severity (UCEIS) and validated it with an independent cohort of investigators. METHODS: We created a new library of 57 videos of flexible sigmoidoscopy and stratified them based on disease severity. Twenty-five investigators were each randomly assigned to assess 28 videos (which included 4 duplicates to assess intraobserver reliability). Investigators were blinded to clinical details except for 2 of 4 duplicated videos (to assess the impact of knowledge of symptoms on assessment). Three descriptors ("vascular pattern", "bleeding", and "erosions and ulcers") comprising the UCEIS were scored with a visual analogue scale (VAS) to assess overall severity. Intrainvestigator and interinvestigator agreement was characterized by κ statistical analysis; reliability ratios were used to compare VAS and UCEIS scores. RESULTS: There was a high level of correlation between UCEIS scores and overall assessment of severity (correlation coefficient, 0.93). Internal consistency (Cronbach α analysis) was 0.86. Intrainvestigator and interinvestigator reliability ratios for UCEIS scores were 0.96 and 0.88, respectively. Intrainvestigator agreement in determination of the UCEIS score was good (κ = 0.72), with individual descriptors ranging from a κ of 0.47 (for bleeding) to 0.87 (for vascular pattern). Interinvestigator agreement in determination of UCEIS scores was moderate (κ = 0.50), with descriptors ranging from a κ of 0.48 (for bleeding) to 0.54 (for vascular pattern). Intrainvestigator variability in determining UCEIS scores did not change appreciably when a video was presented with clinical details. CONCLUSIONS: The UCEIS and its components show satisfactory intrainvestigator and interinvestigator reliability. Among investigators, the UCEIS accounted for a median of 86% of the variability in evaluation of overall severity on the VAS when assessing the endoscopic severity of UC and was unaffected by knowledge of clinical details

    The Impact of Clinical Information on the Assessment of Endoscopic Activity: Characteristics of the Ulcerative Colitis Endoscopic Index Of Severity [UCEIS].

    No full text
    BACKGROUND AND AIMS: To determine whether clinical information influences endoscopic scoring by central readers using the Ulcerative Colitis Endoscopic Index of Severity [UCEIS; comprising 'vascular pattern', 'bleeding', 'erosions and ulcers']. METHODS: Forty central readers performed 28 evaluations, including 2 repeats, from a library of 44 video sigmoidoscopies stratified by Mayo Clinic Score. Following training, readers were randomised to scoring with ['unblinded', n = 20, including 4 control videos with misleading information] or without ['blinded', n 20] clinical information. A total of 21 virtual Central Reader Groups [CRGs], of three blinded readers, were created. Agreement criteria were pre-specified. Kappa [κ] statistics quantified intra- and inter-reader variability. RESULTS: Mean UCEIS scores did not differ between blinded and unblinded readers for any of the 40 main videos. UCEIS standard deviations [SD] were similar [median blinded 0.94, unblinded 0.93; p = 0.97]. Correlation between UCEIS and visual analogue scale [VAS] assessment of overall severity was high [r blinded = 0.90, unblinded = 0.93; p = 0.02]. Scores for control videos were similar [UCEIS: p ≥ 0.55; VAS: p ≥ 0.07]. Intra- [κ 0.47-0.74] and inter-reader [κ 0.40-0.53] variability for items and full UCEIS was 'moderate'-to-'substantial', with no significant differences except for intra-reader variability for erosions and ulcers [κ blinded: 0.47 vs unblinded: 0.74; p 0.047]. The SD of CRGs was lower than for individual central readers [0.54 vs 0.95; p &lt; 0.001]. Correlation between blinded UCEIS and patient-reported symptoms was high [stool frequency: 0.76; rectal bleeding: 0.82; both: 0.81]. CONCLUSIONS: The UCEIS is minimally affected by knowledge of clinical details, strongly correlates with patient-reported symptoms, and is a suitable instrument for trials. CRGs performed better than individuals

    Reliability and initial validation of the ulcerative colitis endoscopic index of severity.

    No full text
    BACKGROUND and AIMS: We studied the reliability of the previously described Ulcerative Colitis Endoscopic Index of Severity (UCEIS) and validated it with an independent cohort of investigators. METHODS: We created a new library of 57 videos of flexible sigmoidoscopy and stratified them based on disease severity. Twenty-five investigators were each randomly assigned to assess 28 videos (which included 4 duplicates to assess intraobserver reliability). Investigators were blinded to clinical details except for 2 of 4 duplicated videos (to assess the impact of knowledge of symptoms on assessment). Three descriptors ("vascular pattern", "bleeding", and "erosions and ulcers") comprising the UCEIS were scored with a visual analogue scale (VAS) to assess overall severity. Intrainvestigator and interinvestigator agreement was characterized by κ statistical analysis; reliability ratios were used to compare VAS and UCEIS scores. RESULTS: There was a high level of correlation between UCEIS scores and overall assessment of severity (correlation coefficient, 0.93). Internal consistency (Cronbach α analysis) was 0.86. Intrainvestigator and interinvestigator reliability ratios for UCEIS scores were 0.96 and 0.88, respectively. Intrainvestigator agreement in determination of the UCEIS score was good (κ = 0.72), with individual descriptors ranging from a κ of 0.47 (for bleeding) to 0.87 (for vascular pattern). Interinvestigator agreement in determination of UCEIS scores was moderate (κ = 0.50), with descriptors ranging from a κ of 0.48 (for bleeding) to 0.54 (for vascular pattern). Intrainvestigator variability in determining UCEIS scores did not change appreciably when a video was presented with clinical details. CONCLUSIONS: The UCEIS and its components show satisfactory intrainvestigator and interinvestigator reliability. Among investigators, the UCEIS accounted for a median of 86% of the variability in evaluation of overall severity on the VAS when assessing the endoscopic severity of UC and was unaffected by knowledge of clinical details
    corecore