1,080 research outputs found

    Energy partition in Sapphire and BGO scintillating bolometers

    No full text
    International audienceScintillating bolometers are particle detectors with a high particle discrimination power with many applications in nuclear and particle physics. This discrimination power is based on the different scintillation yield for different particles, and is strongly dependent on the target used. At the very low temperatures required for the operation of the bolometers, very few data about the scintillation yields are available. In this paper we present estimates of absolute light yields and energy partition among heat, light and trapping channels in Sapphire (AlO) and BGO (BiGeO) scintillating bolometers operated at 20 mK. The estimate relies on the observed negative correlation between the light and heat signals produced by γ-ray absorption in scintillating bolometers and on the study of the x-ray stimulated luminescence properties of BGO at temperatures down to 77 K

    Neutron Spectrometry with Scintillating Bolometers of LiF and Sapphire

    Get PDF
    Two scintillating bolometers of LiF (33 g) and Al2O3 (50 g) at 20 mK, inside a lead shielding at the Canfranc Underground Laboratory, were irradiated with neutrons from a source of 252Cf. The analysis of nuclear recoils registered by sapphire and (n, a) captures by 6Li shows the feasibility of these cryogenic devices to measure the spectral flux of a neutron field. Data unfolding was done assuming that the spectral flux is a piecewise constant function defined on six energy groups. It can be solved by using non-negative least squares without additional assumptions on the neutron flux. The model provides consistent results with the spectra of the observed events in bolometers, giving a fast neutron flux of F(E > 0.1 MeV) = 0.20 n s-1cm-2 with a 15% uncertainty after 3 hours of live time. After our analysis, it can be concluded that nuclear recoils in sapphire are more useful than (n, a) captures in LiF for spectrometry of fast neutrons

    Description of current-driven torques in magnetic tunnel junctions

    Get PDF
    A free electron description of spin-dependent tranport in magnetic tunnel junctions with non collinear magnetizations is presented. We investigate the origin of transverse spin density in tunnelling transport and the quantum interferences which give rise to oscillatory torques on the local magnetization. Spin transfer torque is also analyzed and an important bias asymmetry is found as well as a damped oscillatory behaviour. Furthermore, we investigate the influence of the s-d exchange coupling on torque in particular in the case of half-metallic MTJ in which the spin transfer torque is due to interfacial spin-dependent reflections

    Response of parylene-coated NaI(Tl) scintillators at low temperature

    Get PDF
    Despite that it is widely used as a scintillator at room temperature, the hygroscopicity of NaI complicates its handling and limits its application for many purposes, for example as a cryogenic detector. To overcome this problem we study coating materials that can act as humidity barriers, in particular parylene, a polymer that can be deposited in very radiopure, thin and conformal layers. In this work, several NaI(Tl) samples coated with 2-5 µm parylene-C were tested at low temperature. Luminescence spectra under X-ray excitation are presented at several temperatures as well as the light output vs temperature at 1.5-300 K. Several thermoluminescence peaks were observed at around 60, 95 and 150 K during warm up to room temperature The mechanical resistance of the coating under thermal cycles was also investigated, and we observed a degradation of the optical appearance and the light output after cooling down to about 100 mK, which compromises the reusability of the samples

    Thin PDMS Films Using Long Spin Times or Tert-Butyl Alcohol as a Solvent

    Get PDF
    Thin polydimethylsiloxane (PDMS) films are frequently used in “lab on a chip” devices as flexible membranes. The common solvent used to dilute the PDMS for thin films is hexane, but hexane can swell the underlying PDMS substrate. A better solvent would be one that dissolves uncured PDMS but doesn't swell the underlying substrate. Here, we present protocols and spin curves for two alternatives to hexane dilution: longer spin times and dilution in tert-butyl alcohol. The thickness of the PDMS membranes under different spin speeds, spin times, and PDMS concentrations was measured using an optical profilometer. The use of tert-butyl alcohol to spin thin PDMS films does not swell the underlying PDMS substrate, and we have used these films to construct multilayer PDMS devices

    Extensive Copy-Number Variation of Young Genes across Stickleback Populations

    Get PDF
    MM received funding from the Max Planck innovation funds for this project. PGDF was supported by a Marie Curie European Reintegration Grant (proposal nr 270891). CE was supported by German Science Foundation grants (DFG, EI 841/4-1 and EI 841/6-1). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript

    Proceedings of the third French-Ukrainian workshop on the instrumentation developments for HEP

    Full text link
    The reports collected in these proceedings have been presented in the third French-Ukrainian workshop on the instrumentation developments for high-energy physics held at LAL, Orsay on October 15-16. The workshop was conducted in the scope of the IDEATE International Associated Laboratory (LIA). Joint developments between French and Ukrainian laboratories and universities as well as new proposals have been discussed. The main topics of the papers presented in the Proceedings are developments for accelerator and beam monitoring, detector developments, joint developments for large-scale high-energy and astroparticle physics projects, medical applications.Comment: 3rd French-Ukrainian workshop on the instrumentation developments for High Energy Physics, October 15-16, 2015, LAL, Orsay, France, 94 page

    A comparison of surgical devices for grade II and III hemorrhoidal disease. Results from the LigaLongo Trial comparing transanal Doppler-guided hemorrhoidal artery ligation with mucopexy and circular stapled hemorrhoidopexy

    Get PDF
    PURPOSE: Little is presently known on the impact of device type for Doppler-guided hemorrhoidal artery ligation/mucopexy (DGHAL) or circular stapled hemorrhoidopexy (CSH) when a surgical treatment is considered for hemorrhoidal disease (HD). In this study, we aimed to compare the outcome in terms of adverse events and recurrence rate, of patients included in the multicenter LigaLongo RCT ( ClinicalTrials.gov NCT01240772) according to the type of devices used. METHODS: In the DGHAL arm (N = 193), the procedure was done with transanal hemorrhoidal dearterialization (THD)™ (THD, Correggio, Italy) (104 patients) and with HAL-RAR™ (Agency for Medical Innovations (AMI) GmbH, Feldkirch, Austria) (89 patients). In the CSH arm (N = 184), procedure for prolapse and hemorrhoids (PPH)-03™ (Ethicon Endo-Surgery, Cincinnati OH) and hemorrhoidopexy and prolapse (HEM)™ (Covidien, Inc.) staplers were used in respectively 106 and 78 cases. Surgery-related morbidity at 90 postoperative days (POD) based on the Clavien-Dindo procedure-related complication score and clinical outcome in terms of recurrence and reoperation rate at 12 postoperative months (POM) was collected. RESULTS: Three hundred and seventy-seven patients were randomized according to HD grade. In the DGHAL arm, the number of ligations and mucopexies was higher in the AMI group (p < 0.0001); at 90 POD, the overall morbidity was similar between the two groups. In the CSH arm, donut sizes were similar; at 90 POD, the PPH group had a higher risk of postoperative grade 1 morbidity (anal urgency or incontinence) compared to the HEM group (p = 0.003). At 12 POM, no statistical difference was found between the two groups of each arm in terms of grade III recurrence or reoperation. CONCLUSION: Postoperative morbidity and outcome at 1 year were similar regardless of the type of devices used. These findings suggest that device type has little impact on HD treatment results. TRIAL REGISTRATION: clinicaltrials.gov -Identifier NCT01240772

    Capillary Bridge Formation and Breakage: A Test to Characterize Antiadhesive Surfaces

    Full text link
    In order to characterize very weak adhesive surfaces, we have developed a quantitative test inspired by the Johnson, Kendall, and Roberts adhesion test for soft adhesives, which relies on the formation and then the rupture of a capillary bridge between the surface to be tested and a liquid bath. Both the shape and the kinetics of breakage of the capillary bridge for various coatings put into contact with liquids of various viscosities and surface tensions have been studied. Several pull off regimes can be distinguished. For low pull off velocities, a quasi-static regime is observed, well described by capillary equations and sensitive to the hysteresis of the contact angle of the fluid on the coating. Above a critical pull off velocity that depends on the fluid viscosity, a dynamic regime is observed, characterized by the formation of a flat pancake of fluid on the coating that recedes more slowly than the capillary bridge itself. After the breakage of the capillary bridge, a small drop can remain attached to the surface. The volume of this drop depends on the dynamical regime and is strongly affected by very small differences between the coatings. The aptitude of this test in characterizing very weakly adhesive surfaces is exemplified by a comparison between three different perfluorinated coatings
    corecore