26,716 research outputs found
On-Body Channel Measurement Using Wireless Sensors
© 2012 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other users, including reprinting/ republishing this material for advertising or promotional purposes, creating new collective
works for resale or redistribution to servers or lists, or reuse of any copyrighted components of this work in other works.This post-acceptance version of the paper is essentially complete, but may differ from the official copy of record, which can be found at the following web location (subscription required to access full paper): http://dx.doi.org/10.1109/TAP.2012.219693
Environmental Dependence of Cold Dark Matter Halo Formation
We use a high-resolution -body simulation to study how the formation of
cold dark matter (CDM) halos is affected by their environments, and how such
environmental effects produce the age-dependence of halo clustering observed in
recent -body simulations. We estimate, for each halo selected at redshift
, an `initial' mass defined to be the mass enclosed by the
largest sphere which contains the initial barycenter of the halo particles and
within which the mean linear density is equal to the critical value for
spherical collapse at . For halos of a given final mass, , the
ratio has large scatter, and the scatter is larger for
halos of lower final masses. Halos that form earlier on average have larger
, and so correspond to higher peaks in the initial density
field than their final masses imply. Old halos are more strongly clustered than
younger ones of the same mass because their initial masses are larger. The
age-dependence of clustering for low-mass halos is entirely due to the
difference in the initial/final mass ratio. Low-mass old halos are almost
always located in the vicinity of big structures, and their old ages are
largely due to the fact that their mass accretions are suppressed by the hot
environments produced by the tidal fields of the larger structure. The
age-dependence of clustering is weaker for more massive halos because the
heating by large-scale tidal fields is less important.Comment: 18 pages,19 figures, accepted by MNRA
Accurate determination of the Lagrangian bias for the dark matter halos
We use a new method, the cross power spectrum between the linear density
field and the halo number density field, to measure the Lagrangian bias for
dark matter halos. The method has several important advantages over the
conventional correlation function analysis. By applying this method to a set of
high-resolution simulations of 256^3 particles, we have accurately determined
the Lagrangian bias, over 4 magnitudes in halo mass, for four scale-free models
with the index n=-0.5, -1.0, -1.5 and -2.0 and three typical CDM models. Our
result for massive halos with ( is a characteristic non-linear
mass) is in very good agreement with the analytical formula of Mo & White for
the Lagrangian bias, but the analytical formula significantly underestimates
the Lagrangian clustering for the less massive halos $M < M_*. Our simulation
result however can be satisfactorily described, with an accuracy better than
15%, by the fitting formula of Jing for Eulerian bias under the assumption that
the Lagrangian clustering and the Eulerian clustering are related with a linear
mapping. It implies that it is the failure of the Press-Schechter theories for
describing the formation of small halos that leads to the inaccuracy of the Mo
& White formula for the Eulerian bias. The non-linear mapping between the
Lagrangian clustering and the Eulerian clustering, which was speculated as
another possible cause for the inaccuracy of the Mo & White formula, must at
most have a second-order effect. Our result indicates that the halo formation
model adopted by the Press-Schechter theories must be improved.Comment: Minor changes; accepted for publication in ApJ (Letters) ; 11 pages
with 2 figures include
Response-surface-model-based system sizing for nearly/net zero energy buildings under uncertainty
Properly treating uncertainty is critical for robust system sizing of nearly/net zero energy buildings (ZEBs). To treat uncertainty, the conventional method conducts Monte Carlo simulations for thousands of possible design options, which inevitably leads to computation load that is heavy or even impossible to handle. In order to reduce the number of Monte Carlo simulations, this study proposes a response-surface-model-based system sizing method. The response surface models of design criteria (i.e., the annual energy match ratio, self-consumption ratio and initial investment) are established based on Monte Carlo simulations for 29 specific design points which are determined by Box-Behnken design. With the response surface models, the overall performances (i.e., the weighted performance of the design criteria) of all design options (i.e., sizing combinations of photovoltaic, wind turbine and electric storage) are evaluated, and the design option with the maximal overall performance is finally selected. Cases studies with 1331 design options have validated the proposed method for 10,000 randomly produced decision scenarios (i.e., users’ preferences to the design criteria). The results show that the established response surface models reasonably predict the design criteria with errors no greater than 3.5% at a cumulative probability of 95%. The proposed method reduces the number of Monte Carlos simulations by 97.8%, and robustly sorts out top 1.1% design options in expectation. With the largely reduced Monte Carlo simulations and high overall performance of the selected design option, the proposed method provides a practical and efficient means for system sizing of nearly/net ZEBs under uncertainty
Investigation on thermal-hydraulic performance of outdoor heat exchanger in air sources heat pump
A plethora of findings exists on the decreasing heat transfer performance of ASHP under frosting condition. This study investigates, using field and laboratory experiments, the frosting behavior and heat transfer performance of fin-tube exchangers. Findings from our initial observation revealed the severity of frosting phenomenon during winter in hot summer and cold winter zone of China; for avoiding the lower COP, defrosting period of ASHP was not longer than 60 min. The results showed that the basic tube surface temperature decreases with running time and remains stable after 70 min, and an adverse pressure drop ensued. The findings, thereby suggests a 70 min defrosting period in ASHP. Comparing jH/fH and COP between exchangers revealed an improved performance of plain fin-tube exchanger over that of louver fin-tube exchanger in all the test conditions. Therefore, under frosting condition, plain fin-tube heat exchanger provides a superior thermal-hydraulic performance over louver fin-tube heat exchanger. Findings from this study will help designers and facility managers in taking a more informed decision when selecting heat exchanger types for ASHP
- …
