334 research outputs found

    STUDY ON GYMNASTICS RING MOVEMENTS USING FORCE MEASURING SYSTEM

    Get PDF
    The purpose of this paper was to analyze five giant-swing phases performed on the rings using force-measuring system, which was synchronized with EMG and film. The results showed similar patterns in pulling force, shoulder angle, hip angle, hip velocity and ankle velocity when performing the movements of backward swing phase, dropped shoulder, giant-swing, and upward swing phase. The pulling-force changed from smaller than the body weight to greater than the body weight in the process of the backward swing. The first peak of pulling force occurred as shoulder drop phase ends. The second peak of pulling force occurred in the backward swing phase. The pulling force decreased gradually in the process of the upward swing

    COMPARISON OF CIRCULATING DENDRITIC CELLS AND MONOCYTE SUBSETS AT DIFFERENT STAGES OF ATHEROSCLEROSIS

    Get PDF

    Resonant gas sensing in the terahertz spectral range using two-wire phase-shifted waveguide Bragg gratings

    Get PDF
    ABSTRACT: The development of low-cost sensing devices with high compactness, flexibility, and robustness is of significance for practical applications of optical gas sensing. In this work, we propose a waveguide-based resonant gas sensor operating in the terahertz frequency band. It features micro-encapsulated two-wire plasmonic waveguides and a phase-shifted waveguide Bragg grating (WBG). The modular semi-sealed structure ensures the controllable and efficient interaction between terahertz radiation and gaseous analytes of small quantities. WBG built by superimposing periodical features on one wire shows high reflection and a low transmission coefficient within the grating stopband. Phase-shifted grating is developed by inserting a Fabry–Perot cavity in the form of a straight waveguide section inside the uniform gratings. Its spectral response is optimized for sensing by tailoring the cavity length and the number of grating periods. Gas sensor operating around 140 GHz, featuring a sensitivity of 144 GHz/RIU to the variation in the gas refractive index, with resolution of 7 X 10 -5 RIU, is developed. In proof-of-concept experiments, gas sensing was demonstrated by monitoring the real-time spectral response of the phase-shifted grating to glycerol vapor flowing through its sealed cavity. We believe that the phase-shifted grating-based terahertz resonant gas sensor can open new opportunities in the monitoring of gaseous analytes

    Strain fields of Ms >6.0 earthquakes in Menyuan, Qinghai, China

    Get PDF
    In predicting earthquakes, it is a major challenge to capture the time factor and spatial isoline anomalies, and understand their physical processes, of the seismic strain field before a strong earthquake. In this study, the seismic strain field was used as representative of seismic activity. The natural orthogonal function expansion method was used to calculate the seismic strain field before the Menyuan Ms 6.4 earthquakes in 1986 and 2016, and the Ms 6.9 earthquake in 2022. Time factor and spatial isoline anomaly of the strain field before each earthquake was extracted. We also compared the evolution of the strain field with numerical simulation results under the tectonic stress system at the source. The results showed that the time factor before the earthquakes had high or low value anomalies, exceeding the mean square error of the stable background. The anomalies were concentrated in the first four typical fields of the strain field, which has multiple components. The abnormal contribution rate of the first typical field is the largest (accounting for 42%–49% of the total field). The long- and medium-term anomalies appear 3-4, and 1-2 years before the earthquake, respectively. There were no short or immediate-term anomalies within 3 months of the earthquake. In addition, during the evolution of the strain field, the abnormal area of the spatial isoline changed with the change in time. Usually, the intersection area of the two isoseismic lines of strain accumulation and strain release becomes a potential location for strong earthquakes. Finally, we found that the high strain field values of the 1986 and 2016 Ms 6.4 earthquakes were equivalent to the numerical simulation results, while the high strain field values of the 2022 Menyuan Ms 6.9 earthquakes were slightly different, but within the accepted error range. These results indicate that the two methods are consistent. We have shown that the natural orgthagonal method can be used to obtain the spatiotemporal anomaly information of strain field preceding strong earthquakes

    Enhancing the lift-off performance of EMATs by applying an Fe3O4 coating to a test specimen

    Get PDF
    Electromagnetic acoustic transducers (EMATs) are non-contact ultrasonic transducers. The transduction efficiency of a particular EMAT on a given specimen is dependent on the lift-off distance, which is the distance between the EMAT coil and the specimen surface. The transduction efficiency drops dramatically with increased lift-off distance, requiring EMATs to be in close proximity to the specimen, usually within a few millimetres. This paper proposes a new EMAT method of applying an Fe 3 O 4 coating to the test specimen, and quantitatively studying the enhancement effect of Fe 3 O 4 coating on lift-off distance. To eliminate the interference of the electrical and magnetic properties of the tested specimen, a non-magnetic and non-conductive glass specimen is selected. The experimental results on a glass substrate coated with Fe 3 O 4 demonstrate the feasibility of EMATs generating and receiving ultrasonic waves through the coating, by a magneto-elastic mechanism. The transduction efficiency of EMATs on an Fe 3 O 4 coating does not increase linearly with the bias static magnetic field, and the maximum measured signal amplitude value occurs at a relatively low flux density of ~0.12 T. More specifically, it has been shown the Fe 3 O 4 coating can significantly enhance the lift-off distance of EMATs operating at 4 MHz to 8 mm on coated stainless steel. The performance of the Fe 3 O 4 coating can be optimized, showing considerable potential to expand the application range of EMATs
    • …
    corecore