101 research outputs found

    Prediction of trabecular bone architectural features by deep learning models using simulated DXA images

    Get PDF
    Dual-energy X-ray absorptiometry (DXA) is widely used for clinical assessment of bone mineral density (BMD). Recent evidence shows that DXA images may also contain microstructural information of trabecular bones. However, no current image processing techniques could aptly extract the information. Inspired by the success of deep learning techniques in medical image analyses, we hypothesized in this study that DXA image-based deep learning models could predict the major microstructural features of trabecular bone with a reasonable accuracy. To test the hypothesis, 1249 trabecular cubes (6 mm × 6 mm × 6 mm) were digitally dissected out from the reconstruction of seven human cadaveric proximal femurs using microCT scans. From each cube, simulated DXA images in designated projections were generated, and the histomorphometric parameters (i.e., BV/TV, BS, Tb.Th, DA, Conn. D, and SMI) of the cube were determined using Image J. Convolutional neural network (CNN) models were trained using the simulated DXA images to predict the histomorphometric parameters of trabecular bone cubes. The results exhibited that the CNN models achieved high fidelity in predicting these histomorphometric parameters (from R = 0.80 to R = 0.985), showing that the DL models exhibited the capability of predicting the microstructural features using DXA images. This study also showed that the number and resolution of input simulated DXA images had considerable impacts on the prediction accuracy of the DL models. These findings support the hypothesis of this study and indicate a high potential of using DXA images in prediction of osteoporotic bone fracture risk

    Low-mass dark matter search results from full exposure of PandaX-I experiment

    Full text link
    We report the results of a weakly-interacting massive particle (WIMP) dark matter search using the full 80.1\;live-day exposure of the first stage of the PandaX experiment (PandaX-I) located in the China Jin-Ping Underground Laboratory. The PandaX-I detector has been optimized for detecting low-mass WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid xenon target mass of 54.0\,kg, no significant excess event were found above the expected background. A profile likelihood analysis confirms our earlier finding that the PandaX-I data disfavor all positive low-mass WIMP signals reported in the literature under standard assumptions. A stringent bound on the low mass WIMP is set at WIMP mass below 10\,GeV/c2^2, demonstrating that liquid xenon detectors can be competitive for low-mass WIMP searches.Comment: v3 as accepted by PRD. Minor update in the text in response to referee comments. Separating Fig. 11(a) and (b) into Fig. 11 and Fig. 12. Legend tweak in Fig. 9(b) and 9(c) as suggested by referee, as well as a missing legend for CRESST-II legend in Fig. 12 (now Fig. 13). Same version as submitted to PR
    • …
    corecore