153 research outputs found
Two-pion Bose-Einstein correlations in central Pb-Pb collisions at = 2.76 TeV
The first measurement of two-pion Bose-Einstein correlations in central Pb-Pb
collisions at TeV at the Large Hadron Collider is
presented. We observe a growing trend with energy now not only for the
longitudinal and the outward but also for the sideward pion source radius. The
pion homogeneity volume and the decoupling time are significantly larger than
those measured at RHIC.Comment: 17 pages, 5 captioned figures, 1 table, authors from page 12,
published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/388
Suppression of charged particle production at large transverse momentum in central Pb-Pb collisions at TeV
Inclusive transverse momentum spectra of primary charged particles in Pb-Pb
collisions at = 2.76 TeV have been measured by the ALICE
Collaboration at the LHC. The data are presented for central and peripheral
collisions, corresponding to 0-5% and 70-80% of the hadronic Pb-Pb cross
section. The measured charged particle spectra in and GeV/ are compared to the expectation in pp collisions at the same
, scaled by the number of underlying nucleon-nucleon
collisions. The comparison is expressed in terms of the nuclear modification
factor . The result indicates only weak medium effects ( 0.7) in peripheral collisions. In central collisions,
reaches a minimum of about 0.14 at -7GeV/ and increases
significantly at larger . The measured suppression of high- particles is stronger than that observed at lower collision energies,
indicating that a very dense medium is formed in central Pb-Pb collisions at
the LHC.Comment: 15 pages, 5 captioned figures, 3 tables, authors from page 10,
published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/98
Reproducible mini-slump test procedure for measuring the yield stress of cementitious pastes
The mini-slump test is a fast, inexpensive and widely adopted method for evaluating the workability of fresh cementitious pastes. However, this method lacks a standardised procedure for its experimental implementation, which is crucial to guarantee reproducibility and reliability of the test results. This study investigates and proposes a guideline procedure for mini-slump testing, focusing on the influence of key experimental (mixing and testing) parameters on the statistical performance of the results. The importance of preparation of always testing at the same time after mixing, testing each batch once rather than conducting multiple tests on a single batch of material, is highlighted. A set of alkali-activated fly ash-slag pastes, spanning from 1 to 75 Pa yield stresses, were used to validate the test method, by comparison of calculated yield stresses with the results obtained using a conventional vane viscometer. The proposed experimental procedure for mini-slump testing produces highly reproducible results, and the yield stress calculated from mini-slump values correlate very well with those measured by viscometer, in the case of fresh paste of pure shear flow. Mini-slump testing is a reliable method that can be utilised for the assessment of workability of cements
The Electronics and Data Acquisition System of the DarkSide Dark Matter Search
It is generally inferred from astronomical measurements that Dark Matter (DM)
comprises approximately 27\% of the energy-density of the universe. If DM is a
subatomic particle, a possible candidate is a Weakly Interacting Massive
Particle (WIMP), and the DarkSide-50 (DS) experiment is a direct search for
evidence of WIMP-nuclear collisions. DS is located underground at the
Laboratori Nazionali del Gran Sasso (LNGS) in Italy, and consists of three
active, embedded components; an outer water veto (CTF), a liquid scintillator
veto (LSV), and a liquid argon (LAr) time projection chamber (TPC). This paper
describes the data acquisition and electronic systems of the DS detectors,
designed to detect the residual ionization from such collisions
Long-term Monitoring on Mrk 501 for Its VHE gamma Emission and a Flare in October 2011
As one of the brightest active blazars in both X-ray and very high energy
-ray bands, Mrk 501 is very useful for physics associated with jets
from AGNs. The ARGO-YBJ experiment is monitoring it for -rays above 0.3
TeV since November 2007. Starting from October 2011 the largest flare since
2005 is observed, which lasts to about April 2012. In this paper, a detailed
analysis is reported. During the brightest -rays flaring episodes from
October 17 to November 22, 2011, an excess of the event rate over 6 is
detected by ARGO-YBJ in the direction of Mrk 501, corresponding to an increase
of the -ray flux above 1 TeV by a factor of 6.62.2 from its steady
emission. In particular, the -ray flux above 8 TeV is detected with a
significance better than 4 . Based on time-dependent synchrotron
self-Compton (SSC) processes, the broad-band energy spectrum is interpreted as
the emission from an electron energy distribution parameterized with a single
power-law function with an exponential cutoff at its high energy end. The
average spectral energy distribution for the steady emission is well described
by this simple one-zone SSC model. However, the detection of -rays
above 8 TeV during the flare challenges this model due to the hardness of the
spectra. Correlations between X-rays and -rays are also investigated.Comment: have been accepted for publication at Ap
Higher harmonic anisotropic flow measurements of charged particles in Pb-Pb collisions at 2.76 TeV
We report on the first measurement of the triangular , quadrangular
, and pentagonal charged particle flow in Pb-Pb collisions at 2.76
TeV measured with the ALICE detector at the CERN Large Hadron Collider. We show
that the triangular flow can be described in terms of the initial spatial
anisotropy and its fluctuations, which provides strong constraints on its
origin. In the most central events, where the elliptic flow and
have similar magnitude, a double peaked structure in the two-particle azimuthal
correlations is observed, which is often interpreted as a Mach cone response to
fast partons. We show that this structure can be naturally explained from the
measured anisotropic flow Fourier coefficients.Comment: 10 pages, 4 figures, published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/387
Planck intermediate results I : Further validation of new Planck clusters with XMM-Newton
Peer reviewe
Planck Intermediate Results II: Comparison of SunyaevâZeldovich measurements from Planck and from the Arcminute Microkelvin Imager for 11 galaxy clusters
A comparison is presented of SunyaevâZeldovich measurements for 11 galaxy clusters as obtained by Planck and by the ground-based interferom- eter, the Arcminute Microkelvin Imager. Assuming a universal spherically-symmetric Generalised Navarro, Frenk & White (GNFW) model for the cluster gas pressure profile, we jointly constrain the integrated Compton-Y parameter (Y500) and the scale radius (Ξ500) of each cluster. Our resulting constraints in the Y500 â Ξ500 2D parameter space derived from the two instruments overlap significantly for eight of the clusters, although, overall, there is a tendency for AMI to find the SunyaevâZeldovich signal to be smaller in angular size and fainter than Planck. Significant discrepancies exist for the three remaining clusters in the sample, namely A1413, A1914, and the newly-discovered Planck cluster PLCKESZ G139.59+24.18. The robustness of the analysis of both the Planck and AMI data is demonstrated through the use of detailed simulations, which also discount confusion from residual point (radio) sources and from diffuse astrophysical foregrounds as possible explanations for the discrepancies found. For a subset of our cluster sample, we have investigated the dependence of our results on the assumed pressure profile by repeating the analysis adopting the best-fitting GNFW profile shape which best matches X-ray observations. Adopting the best-fitting profile shape from the X-ray data does not, in general, resolve the discrepancies found in this subset of five clusters. Though based on a small sample, our results suggest that the adopted GNFW model may not be sufficiently flexible to describe clusters universally
Outcomes from elective colorectal cancer surgery during the SARS-CoV-2 pandemic
This study aimed to describe the change in surgical practice and the impact of SARS-CoV-2 on mortality after surgical resection of colorectal cancer during the initial phases of the SARS-CoV-2 pandemic
- âŠ