2,849 research outputs found

    Estimating Health Care Costs Among Fragile and Conflict Affected States: an Elastic Net-Risk Measures Approach

    Get PDF
    Fragile and conflict affected states (FCAS) are those in which the government lacks the political will and/or capacity to provide the basic functions necessary for poverty reduction, economic development, and the security of human rights of their populations.Until recent history, unfortunately, the majority of research conducted and universal health care debates have been centered around middle income and emerging economies. As a result, FCAS have been neglected from many global discussions and decisions. Due to this neglect, many FCAS do not have proper vaccinations and antibiotics. Seemingly, well estimated health care costs are a necessary stepping stone in improving the health of citizens among FCAS. Fortunately, developments in statistical learning theory combined with data obtained by the WBG and Transparency International make it possible to accurately model health care cost among FCAS. The data used in this paper consisted of 35 countries and 89 variables. Of these 89 variables, health care expenditure (HCE) was the only response variable. With 88 predictor variables, there was expected to be multicollinearity, which occurs when multiple variables share relatively large absolute correlation. Since multicollinearity is expected and the number of variables is far greater than the number of observations, this paper adopts Zou and Hastie\u27s method of regularization via elastic net (ENET). In order to accurately estimate the maximum and expected maximum HCE among FCAS, well-known risk measures, such as Value at Risk and Conditional Value at Risk, and related quantities were obtained via Monte Carlo simulations. This paper obtained risk measures at 95 security level

    Systematics of the odd-even effect in the resonance ionization of Os and Ti

    Get PDF
    Measurements of the odd-even effect in the mass spectrometric analysis of Ti and Os isotopes by resonance ionization mass spectrometry have been performed for ΔJ = + 1, 0 and -1 transitions. Under saturating conditions of the ionization and for ΔJ = + 1 transitions odd-even effects are reduced below the 0.5% level. Depending on the polarization state of the laser large odd isotope enrichments are observed for ΔJ = 0 and -1 transitions which can be reduced below the 0.5% level by depolarization of the laser field

    Laser-induced isotopic selectivity in the resonance ionization of Os

    Get PDF
    Isotope selective effects in resonance ionization mass spectrometry (RIMS) pose a potentially serious limitation to the application of this technique to the precise and reproducible measurement of isotope ratios. In order to identify some of the underlying causes of isotope selectivity in RIMS and to establish procedures for minimizing these effects, we investigated laser-induced isotope selectivity in the resonance ionization of Os. A single-color, one-photon resonant ionization scheme was used for several different transitions to produce Os photoions from a thermal atomization source. Variations in Os isotope ratios were studied as a function of laser parameters such as wavelength, bandwidth, power and polarization state. Isotope selectivity is strongly dependent on laser power and wavelength, even when the bandwidth of the laser radiation is much larger than the optical isotope shift. Variations in the ^(190)Os/^(188)Os ratio of ≈20% for a detuning of 0.8 cm^(−1) were observed on a transition with a small oscillator strength. Large even—odd isotope selectivity with a 13% depletion of ^(189)Os was observed on a ΔJ = +1 transition at low laser intensity; the odd mass Os isotopes are systematically depleted. For ΔJ = −1 and 0 transitions the isotope selectivity was reduced by polarization scrambling and for strongly saturating conditions. A technique employing the wavelength dependence of even—even isotope selectivity as an internal wavelength standard was developed to permit accurate and reproducible wavelength adjustment of the laser radiation. This technique provides control over laser-induced isotope selectivity for single-color ionization and enabled us to obtain reproducible measurements of ^(192)Os/^(188)Os and ^(189)Os/^(190)Os ratios in the saturation regime for a ΔJ = +1 transition with a precision of better than 0.5%. The application of this wavelength-tuning procedure should significantly improve the quality of RIMS isotope ratio data for many elements

    Overcoming Spatial Deskilling Using Landmark-Based Navigation Assistance Systems

    Full text link
    Abstract Background The repeated use of navigation assistance systems leads to decreased spatial orienting abilities. Previous studies demonstrated that augmentation of landmarks using auditory navigation instructions can improve incidental spatial learning when driving on a single route through an unfamiliar environment. Objective Based on these results, a series of experiments was conducted to further investigate both the impairment of spatial knowledge acquisition by standard navigation instructions and the positive impact of landmark augmentation in auditory navigation instructions on incidental spatial learning. Method The first Experiment replicated the previous setup in a driving simulator without additional visual route indicators. In a second experiment, spatial knowledge was tested after watching a video depicting assisted navigation along a real-world urban route. Finally, a third Experiment investigated incidental spatial knowledge acquisition when participants actively navigated through an unrestricted real-world,urban environment. Results All three experiments demonstrated better cued-recall performance for participants navigating with landmark-based auditory navigation instructions as compared to standard instructions. Notably, standard instructions were associated with reduced learning of landmarks at navigation relevant intersections as compared to landmarks alongside straight segments and the recognition of novel landmarks. Conclusion The results revealed a suppression of spatial learning by established navigation instructions, which were overcome by landmark-based navigation instructions. This emphasizes the positive impact of auditory landmark augmentation on incidental spatial learning and its generalizability to real-life settings. Application This research is paving the way for navigation assistants that, instead of impairing orienting abilities, incidentally foster spatial learning during every-day navigation. Précis This series of three experiments replicates the suppression of spatial learning by standard navigation instructions and the positive impact of landmark augmentation in auditory navigation instructions on incidental spatial learning during assisted navigation. Three experiments with growing degree of realism revealed the applicability and generalizability to real-life settings

    Noncontact modulation calorimetry of metallic liquids in low Earth orbit

    Get PDF
    Noncontact modulation calorimetry using electromagnetic heating and radiative heat loss under ultrahigh-vacuum conditions has been applied to levitated solid, liquid, and metastable liquid samples. This experiment requires a reduced gravity environment over an extended period of time and allows the measurement of several thermophysical properties, such as the enthalpy of fusion and crystallization, specific heat, total hemispherical emissivity, and effective thermal conductivity with high precision as a function of temperature. From the results on eutectic glass forming Zr-based alloys thermodynamic functions are obtained which describe the glass-forming ability of these alloys

    Systematics of isotope ratio measurements with resonant laser photoionization sources

    Get PDF
    Sources of laser-induced even-even and odd-even isotopic selectivity in the resonance ionization mass spectroscopy of Os and Ti have been investigated experimentally for various types of transitions. A set of conditions with regard to laser bandwidth and frequency tuning, polarization state and intensity was obtained for which isotopic selectivity is either absent or reduced below the 2 % level

    Laser-induced isotopic effects in titanium resonance ionization

    Get PDF
    Titanium isotope ratios have been measured by resonance ionization mass spectrometry (RIMS) with special emphasis on the nature of laser-induced isotopic selectivity. A pronounced wavelength dependence of even mass isotope ratios is caused by large nuclear volume effects near the magic neutron number 28 in ^(50)Ti . Optical isotope shifts, ranging from 0.07 to 0.21 cm^(-l), between ^(50)Ti and ^(46)Ti were measured for several transitions. The ^(50)Ti/^(46)Ti and ^(48)Ti/^(46)Ti ratios, nevertheless, exhibited only mass-dependent fractionation, in which the lighter Ti isotopes were enriched by ~2.5%/amu, when the laser operating parameters were properly controlled. Odd-even mass isotopic selectivity in the resonant ionization process was also examined for several transitions as a function of the laser polarization state and intensity. Under saturating conditions for a ΔJ= +1 transition and a high degree of laser depolarization for a ΔJ = 0 transition, the odd-even isotopic enhancement was reduced below the 2% level. The Ti isotope data agree with our previous results for Os and indicate that, by a careful choice of resonance transitions and laser operating parameters, isotope ratios can be measured accurately and reliably with RIMS
    • …
    corecore