228 research outputs found

    Salt, blood pressure and cardiovascular risk : what is the most adequate preventive strategy? A Swiss perspective

    Get PDF
    Among the various strategies to reduce the incidence of non-communicable diseases reduction of sodium intake in the general population has been recognized as one of the most cost-effective means because of its potential impact on the development of hypertension and cardiovascular diseases. Yet, this strategic health recommendation of the WHO and many other international organizations is far from being universally accepted. Indeed, there are still several unresolved scientific and epidemiological questions that maintain an ongoing debate. Thus what is the adequate low level of sodium intake to recommend to the general population and whether national strategies should be oriented to the overall population or only to higher risk fractions of the population such as salt-sensitive patients are still discussed. In this paper, we shall review the recent results of the literature regarding salt, blood pressure and cardiovascular risk and we present the recommendations recently proposed by a group of experts of Switzerland. The propositions of the participating medical societies are to encourage national health authorities to continue their discussion with the food industry in order to reduce the sodium intake of food products with a target of mean salt intake of 5-6 grams per day in the population. Moreover, all initiatives to increase the information on the effect of salt on health and on the salt content of food are supported

    Blood pressure and physical activity : time to move (on)

    Get PDF

    Drug adherence in chronic kidney diseases and dialysis.

    Get PDF
    Poor long-term adherence and persistence to drug therapy is universally recognized as one of the major clinical issues in the management of chronic diseases, and patients with renal diseases are also concerned by this important phenomenon. Chronic kidney disease (CKD) patients belong to the group of subjects with one of the highest burdens of daily pill intake with up to >20 pills per day depending on the severity of their disease. The purpose of the present review is to discuss the difficulties encountered by nephrologists in diagnosing and managing poor adherence and persistence in CKD patients including in patients receiving maintenance dialysis. Our review will also attempt to provide some clues and new perspectives on how drug adherence could actually be addressed and possibly improved. Working on drug adherence may look like a long and tedious path, but physicians and healthcare providers should always be aware that drug adherence is in general much lower than what they may think and that there are many ways to improve and support drug adherence and persistence so that renal patients obtain the full benefits of their treatments

    Clinical determinants of adrenal vein sampling success

    Get PDF
    Background: Primary aldosteronism (PA) is one of the most prevalent forms of secondary hypertension, which may be cured by unilateral adrenalectomy. Adrenal vein sampling (AVS) is considered the gold-standard procedure for distinction between bilateral and unilateral aldosterone hypersecretion. However, the procedure is viewed as a technical challenge. The objectives of this study were to define the success rate of AVS, and its clinical determinants, and to compare the accuracy of high-resolution adrenal computed tomography (CT) with AVS. Methods: In this single-centre retrospective study, patients with biologically proven PA who were referred for AVS between 2009 and 2014 were included. Adrenal vein catheterisation was considered selective if the selectivity index (adrenal vein / inferior vena cava cortisol) was ≥2. Results: Data from 68 patients (48% women) were available. The success rate of catheterisation in bilateral AVS was 60% (41/68). The significant clinical determinants of success were male sex (r = 0.35, p = 0.004), a higher body mass index (BMI) (r = 0.54, p = 0.001) and plasma creatinine (r = 0.25, p = 0.048) in univariate analysis. In multivariate linear regression analysis, only BMI was associated with success (coefficient = 0.049, p = 0.004). CT was discordant with AVS in 53% of patients, and would have resulted in inappropriate adrenalectomy in 43% of the patients and inappropriate exclusion from surgery in 10% of the cases. Conclusion: Clinical characteristics such as BMI and sex may influence the success rate of AVS. The inaccuracy of CT may result in inappropriate treatment proposals if the indication for surgical intervention is based on CT only

    Hypertension de la personne âgée : les nouvelles recommandationsont-elles changé la prise en charge ? [Hypertension in the elderly : have new guidelines changed the management ?]

    Get PDF
    Hypertension is highly prevalent in elderly and represents the number one risk factor for cardiac and cerebrovascular complications including cognitive dysfunction. Recently published AHA/ACC and ESC/ESH guidelines for the management of hypertension in adults have modified the approach of hypertension in patients older than 65 years and particularly in those older than 85. The new concepts are the following: the thresholds and target blood pressures for patients older than 65 years are less conservative; emphasis is made on biological rather than chronological age; the use of single pill combinations is favored to simplify treatment algorithms and increase long-term drug adherence. At last, a regular assessment of adherence in collaboration with health care partners is highlighted

    Validation of the optical Aktiia bracelet in different body positions for the persistent monitoring of blood pressure.

    Get PDF
    The diagnosis of hypertension and the adjustment of antihypertensive drugs are evolving from isolated measurements performed at the physician offices to the full phenotyping of patients in real-life conditions. Indeed, the strongest predictor of cardiovascular risk comes from night measurements. The aim of this study was to demonstrate that a wearable device (the Aktiia Bracelet) can accurately estimate BP in the most common body positions of daily life and thus become a candidate solution for the BP phenotyping of patients. We recruited 91 patients with BP ranging from low to hypertensive levels and compared BP values from the Aktiia Bracelet against auscultatory reference values for 4 weeks according to an extended ISO 81060-2 protocol. After initializing on day one, the observed means and standard deviations of differences for systolic BP were of 0.46 ± 7.75 mmHg in the sitting position, - 2.44 ± 10.15 mmHg in the lying, - 3.02 ± 6.10 mmHg in the sitting with the device on the lap, and - 0.62 ± 12.51 mmHg in the standing position. Differences for diastolic BP readings were respectively of 0.39 ± 6.86 mmHg, - 1.93 ± 7.65 mmHg, - 4.22 ± 6.56 mmHg and - 4.85 ± 9.11 mmHg. This study demonstrates that a wearable device can accurately estimate BP in the most common body positions compared to auscultation, although precision varies across positions. While wearable persistent BP monitors have the potential to facilitate the identification of individual BP phenotypes at scale, their prognostic value for cardiovascular events and its association with target organ damage will need cross-sectional and longitudinal studies. Deploying this technology at a community level may be also useful to drive public health interventions against the epidemy of hypertension

    Validation of the optical Aktiia bracelet in different body positions for the persistent monitoring of blood pressure.

    Get PDF
    The diagnosis of hypertension and the adjustment of antihypertensive drugs are evolving from isolated measurements performed at the physician offices to the full phenotyping of patients in real-life conditions. Indeed, the strongest predictor of cardiovascular risk comes from night measurements. The aim of this study was to demonstrate that a wearable device (the Aktiia Bracelet) can accurately estimate BP in the most common body positions of daily life and thus become a candidate solution for the BP phenotyping of patients. We recruited 91 patients with BP ranging from low to hypertensive levels and compared BP values from the Aktiia Bracelet against auscultatory reference values for 4 weeks according to an extended ISO 81060-2 protocol. After initializing on day one, the observed means and standard deviations of differences for systolic BP were of 0.46 ± 7.75 mmHg in the sitting position, - 2.44 ± 10.15 mmHg in the lying, - 3.02 ± 6.10 mmHg in the sitting with the device on the lap, and - 0.62 ± 12.51 mmHg in the standing position. Differences for diastolic BP readings were respectively of 0.39 ± 6.86 mmHg, - 1.93 ± 7.65 mmHg, - 4.22 ± 6.56 mmHg and - 4.85 ± 9.11 mmHg. This study demonstrates that a wearable device can accurately estimate BP in the most common body positions compared to auscultation, although precision varies across positions. While wearable persistent BP monitors have the potential to facilitate the identification of individual BP phenotypes at scale, their prognostic value for cardiovascular events and its association with target organ damage will need cross-sectional and longitudinal studies. Deploying this technology at a community level may be also useful to drive public health interventions against the epidemy of hypertension

    Quantification of endogenous Angiotensin 1-10, 1-9, 1-8, 1-7, and 1-5 in human plasma using micro-UHPLC-MS/MS: Outlining the importance of the pre-analytics for reliable results.

    Get PDF
    Angiotensin peptides (ANGs) play a central role in the renin-angiotensin-aldosterone system, rendering them interesting biomarkers associated with hypertension. Precise quantification of circulating ANGs holds the potential to assess the activity of angiotensin-converting enzyme (ACE), a key protease targeted by widely prescribed drugs, namely ACE inhibitors. This ability could pave the way for personalised medicine, offering insights into the prescription of inhibitors targeting either the proteases or the receptors within the system. Despite recent developments in liquid chromatography-mass spectrometry (LC-MS) methods for measuring circulating ANG concentrations, comprehensive stability studies of ANGs in human plasma are absent in the literature, raising concerns about the reliability of measured concentrations and their link to clinical conditions. To address this critical gap, we conducted an exhaustive evaluation of the pre-analytical stability of ANG1-10, ANG1-9, ANG1-8, ANG1-7, and ANG1-5. By employing surfactants to mitigate non-specific adsorption and a dedicated mix of protease inhibitors to limit protease activity, we established an MS-based assay for these five peptides. We used this method to quantify circulating concentrations of ANGs in the plasma of 11 healthy donors and 3 patients under kidney dialysis. Our findings revealed that ANG1-10 and ANG1-8 circulate at concentrations ranging from 1 to 10 pM in healthy subjects and exhibit a high degree of correlation. Notably, ANG1-9, ANG1-7, and ANG1-5 were undetectable in any of the 14 patients, despite a sub-picomolar limit of detection. This strikingly contrasts with the reference concentrations reported in the literature, which typically fall within the picomolar range. In light of these discrepancies, we strongly advocate for rigorous pre-analytical considerations and comprehensive stability studies to ensure reliable results. We emphasise the pivotal role of heightened pre-analytical awareness within the clinical chemistry community, and we hope for continued growth in this critical area
    corecore