2,619 research outputs found

    Luminosities of AGB Variables

    Get PDF
    The prevailing evidence suggests that most large-amplitude AGB variables follow the period luminosity (PL) relation that has been established for Miras in the LMC and galactic globular clusters. Hipparcos observations indicate that most Miras in the solar neighbourhood are consistent with such a relation. There are two groups of stars with luminosities that are apparently greater than the PL relation would predict: (1) in the LMC and SMC there are large amplitude variables, with long periods, P> 420 days, which are probably undergoing hot bottom burning, but which are very clearly more luminous than the PL relation (these are visually bright and are likely to be among the first stars discovered in more distant intermediate age populations); (2) in the solar neighbourhood there are short period, P<235 days, red stars which are probably more luminous than the PL relation. Similar short-period red stars, with high luminosities, have not been identified in the Magellanic Clouds.Comment: 8 pages, 2 figure, to be published in Mass-Losing Pulsating Stars and their Circumstellar Matter, Y. Nakada & M. Honma (eds) Kluwer ASSL serie

    Photometric Properties of Long-period Variables in the Large Magellanic Cloud

    Get PDF
    Approximately four thousand light curves of red variable stars in the LMC were selected from the 2.3-years duration MOA database by a period analysis using the Phase Dispersion Minimization method. Their optical features (amplitudes, periodicities, position in CMD) were investigated. Stars with large amplitues and high periodicities were distributed on the only one strip amongst multiple structure on the LMC period-luminosity relation. In the CMD, the five strips were located in the order of the period. The stars with characterized light curves were also discussed.Comment: 8 pages, 5 figures, Proceeding of WS on Mass-Losing Pulsating Stars and Their Circumstellar Matter, Sendai, Japa

    Microperimetry hill of vision and volumetric measures of retinal sensitivity

    Get PDF
    Purpose: Mean retinal sensitivity is the main output measure used in microperimetry. It is, however, of limited use in patients with poor vision because averaging is weighted toward zero in those with significant scotomas creating an artificial floor effect. In contrast, volumetric measures avoid these issues and are displayed graphically as a hill of vision. Methods: An open-source program was created to manipulate raw sensitivity threshold data files obtained from MAIA microperimetry. Thin plate spline interpolated heat maps and three-dimensional hill of vision plots with an associated volume were generated. Retrospective analyses of microperimetry volumes were undertaken in patients with a range of retinal diseases to assess the qualitative benefits of three-dimensional visualization and volumetric measures. Simulated pathology was applied to radial grid patterns to investigate the performance of volumetric sensitivity in nonuniform grids. Results: Volumetric analyses from microperimetry in RPGR-related retinitis pigmentosa, choroideremia, Stargardt disease, and age-related macular degeneration were analyzed. In simulated nonuniform testing grids, volumetric sensitivity was able to detect differences in retinal sensitivity where mean sensitivity could not. Conclusions: Volumetric measures do not suffer from averaging issues and demonstrate superior performance in nonuniform testing grids. Additionally, volume measures enable detection of localized retinal sensitivity changes that might otherwise be undetectable in a mean change. Translational Relevance: As microperimetry has become an outcome measure in several gene-therapy clinical trials, three-dimensional visualization and volumetric sensitivity enables a complementary analysis of baseline disease characteristics and subsequent response to treatment, both as a signal of safety and efficacy

    A review of camera trapping for conservation behaviour research

    Get PDF
    An understanding of animal behaviour is important if conservation initiatives are to be effective. However, quantifying the behaviour of wild animals presents significant challenges. Remote-sensing camera traps are becoming increasingly popular survey instruments that have been used to non-invasively study a variety of animal behaviours, yielding key insights into behavioural repertoires. They are well suited to ethological studies and provide considerable opportunities for generating conservation-relevant behavioural data if novel and robust methodological and analytical solutions can be developed. This paper reviews the current state of camera-trap-based ethological studies, describes new and emerging directions in camera-based conservation behaviour, and highlights a number of limitations and considerations of particular relevance for camera-based studies. Three promising areas of study are discussed: (1) documenting anthropogenic impacts on behaviour; (2) incorporating behavioural responses into management planning and (3) using behavioural indicators such as giving up densities and daily activity patterns. We emphasize the importance of reporting methodological details, utilizing emerging camera trap metadata standards and central data repositories for facilitating reproducibility, comparison and synthesis across studies. Behavioural studies using camera traps are in their infancy; the full potential of the technology is as yet unrealized. Researchers are encouraged to embrace conservation-driven hypotheses in order to meet future challenges and improve the efficacy of conservation and management processes

    Determining the best method for first-line assessment of neonatal blood glucose levels

    Get PDF
    Objective: To evaluate and compare the accuracy and performance of two electrochemical glucose meters. To determine the user acceptability of these glucose meters and the ABL 620 Blood Gas Analyser (Radiometer, Copenhagen, Denmark) with an electrochemical glucose oxidase electrode for use in a Level 2 special care baby unit

    Calibration of myocardial T2 and T1 against iron concentration.

    Get PDF
    BACKGROUND: The assessment of myocardial iron using T2* cardiovascular magnetic resonance (CMR) has been validated and calibrated, and is in clinical use. However, there is very limited data assessing the relaxation parameters T1 and T2 for measurement of human myocardial iron. METHODS: Twelve hearts were examined from transfusion-dependent patients: 11 with end-stage heart failure, either following death (n=7) or cardiac transplantation (n=4), and 1 heart from a patient who died from a stroke with no cardiac iron loading. Ex-vivo R1 and R2 measurements (R1=1/T1 and R2=1/T2) at 1.5 Tesla were compared with myocardial iron concentration measured using inductively coupled plasma atomic emission spectroscopy. RESULTS: From a single myocardial slice in formalin which was repeatedly examined, a modest decrease in T2 was observed with time, from mean (± SD) 23.7 ± 0.93 ms at baseline (13 days after death and formalin fixation) to 18.5 ± 1.41 ms at day 566 (p<0.001). Raw T2 values were therefore adjusted to correct for this fall over time. Myocardial R2 was correlated with iron concentration [Fe] (R2 0.566, p<0.001), but the correlation was stronger between LnR2 and Ln[Fe] (R2 0.790, p<0.001). The relation was [Fe] = 5081•(T2)-2.22 between T2 (ms) and myocardial iron (mg/g dry weight). Analysis of T1 proved challenging with a dichotomous distribution of T1, with very short T1 (mean 72.3 ± 25.8 ms) that was independent of iron concentration in all hearts stored in formalin for greater than 12 months. In the remaining hearts stored for <10 weeks prior to scanning, LnR1 and iron concentration were correlated but with marked scatter (R2 0.517, p<0.001). A linear relationship was present between T1 and T2 in the hearts stored for a short period (R2 0.657, p<0.001). CONCLUSION: Myocardial T2 correlates well with myocardial iron concentration, which raises the possibility that T2 may provide additive information to T2* for patients with myocardial siderosis. However, ex-vivo T1 measurements are less reliable due to the severe chemical effects of formalin on T1 shortening, and therefore T1 calibration may only be practical from in-vivo human studies
    corecore