349 research outputs found
Development of Micro-Heaters with Optimized Temperature Compensation Design for Gas Sensors
One of the key components of a chemical gas sensor is a MEMS micro-heater. Micro-heaters are used in both semiconductor gas sensors and NDIR gas sensors; however they each require different heat dissipation characteristics. For the semiconductor gas sensors, a uniform temperature is required over a wide area of the heater. On the other hand, for the NDIR gas sensor, the micro-heater needs high levels of infrared radiation in order to increase sensitivity. In this study, a novel design of a poly-Si micro-heater is proposed to improve the uniformity of heat dissipation on the heating plate. Temperature uniformity of the micro-heater is achieved by compensating for the variation in power consumption around the perimeter of the heater. With the power compensated design, the uniform heating area is increased by 2.5 times and the average temperature goes up by 40 °C. Therefore, this power compensated micro-heater design is suitable for a semiconductor gas sensor. Meanwhile, the poly-Si micro-heater without compensation shows a higher level of infrared radiation under equal power consumption conditions. This indicates that the micro-heater without compensation is more suitable for a NDIR gas sensor. Furthermore, the micro-heater shows a short response time of less than 20ms, indicating a very high efficiency of pulse driving
Long-term outcome of vertebral artery origin stenosis in patients with acute ischemic stroke
BACKGROUND: Vertebral artery origin (VAO) stenosis is occasionally observed in patients who have acute ischemic stroke. We investigated the long-term outcomes and clinical significance of VAO stenosis in patients with acute ischemic stroke. METHODS: We performed a prospective observational study using a single stroke center registry to investigate the risk of recurrent stroke and vascular outcomes in patients with acute ischemic stroke and VAO stenosis. To relate the clinical significance of VAO stenosis to the vascular territory of the index stroke, patients were classified into an asymptomatic VAO stenosis group and a symptomatic VAO stenosis group. RESULTS: Of the 774 patients who had acute ischemic stroke, 149 (19.3%) of them had more than 50% stenosis of the VAO. During 309 patient-years of follow-up (mean, 2.3 years), there were 7 ischemic strokes, 6 hemorrhagic strokes, and 2 unknown strokes. The annual event rates were 0.97% for posterior circulation ischemic stroke, 4.86% for all stroke, and 6.80% for the composite cardiovascular outcome. The annual event rate for ischemic stroke in the posterior circulation was significantly higher in patients who had symptomatic VAO stenosis than in patients who had asymptomatic stenosis (1.88% vs. 0%, p = 0.046). In a multivariate analysis, the hazard ratio, per one point increase of the Essen Stroke Risk Score (ESRS) for the composite cardiovascular outcome, was 1.46 (95% CI, 1.02-2.08, p = 0.036). CONCLUSIONS: Long-term outcomes of more than 50% stenosis of the VAO in patients with acute ischemic stroke were generally favorable. Additionally, ESRS was a predictor for the composite cardiovascular outcome. Asymptomatic VAO stenosis may not be a specific risk factor for recurrent ischemic stroke in the posterior circulation. However, VAO stenosis may require more clinical attention as a potential source of recurrent stroke when VAO stenosis is observed in patients who have concurrent ischemic stroke in the posterior circulation
Nail bed defect reconstruction using a thenar fascial flap and subsequent nail bed grafting
Background Full-thickness nail bed defects with significant exposure of the distal phalanx are typically challenging to reconstruct. We describe a novel method of nail bed defect reconstruction using a thenar fascial flap combined with nail bed grafting. Methods Full-thickness nail bed defects were reconstructed in a 2-stage operation involving the placement of a thenar fascial flap and subsequent nail bed grafting. A proximally-based skin flap was designed on the thenar eminence. The flap was elevated distally to proximally, and the fascial layer covering the thenar muscle was dissected proximally to distally. The skin flap was then closed and the dissected fascial flap was turned over (proximal to distal) and inset onto the defect. The finger was immobilized for 2 weeks, and the flap was dressed with wet and ointment dressings. After 2 weeks, the flap was divided and covered with a split-thickness nail bed graft from the great toe. Subsequent nail growth was evaluated on follow-up. Results Nine patients (9 fingers) treated with the novel procedure were evaluated at follow-up examinations. Complete flap survival was noted in all cases, and all nail bed grafts took successfully. Five outcomes (55.6%) were graded as excellent, three (33.3%) as very good, and one (11.1%) as fair. No donor site morbidities of the thenar area or great toe were observed. Conclusions When used in combination with a nail bed graft, the thenar fascial flap provides an excellent means of nail bed reconstruction
Management of Cerebrospinal Fluid Leakage by Pump-Regulated Volumetric Continuous Lumbar Drainage Following Anterior Cervical Decompression and Fusion for Ossification of the Posterior Longitudinal Ligament
Objective Cerebrospinal fluid (CSF) leakage is a major concern related to anterior cervical decompression and fusion for ossification of the posterior longitudinal ligament (OPLL). We propose a management algorithm for CSF leakage following anterior cervical decompression and fusion for OPLL involving the use of pump-regulated volumetric continuous lumbar drainage. Methods We retrospectively reviewed patients who underwent anterior cervical decompression and fusion for OPLL and were managed with the proposed algorithm between March 2018 and July 2022. The proposed management algorithm for CSF leakage by pump-regulated volumetric continuous lumbar drainage was as follows. On exposure of the arachnoid membrane with or without CSF leakage, a dural sealant patch was applied to manage the dural defect. In case of persistent CSF leakage despite application of the dural sealant patch, patients underwent pump-regulated volumetric continuous lumbar drainage. Results Fifty-one patients were included in the study. CSF leakage occurred in 14 patients. Of these 14 patients, 9 patients underwent lumbar drain insertion according to the proposed management algorithm. Successful resolution of CSF leakage was observed in 8 of the 9 patients who underwent lumbar drainage. All patients were encouraged to ambulate without concern of CSF overdrainage due to gravity, because it could be avoided with pump-regulated volumetric continuous CSF drainage. Therefore, complications associated with absolute bed rest or CSF overdrainage were not observed. Conclusion The proposed management algorithm with pump-regulated volumetric continuous lumbar drainage showed safety and efficacy for management of CSF leakage following anterior decompression and fusion for OPLL
Alishewanella aestuarii sp. nov., isolated from tidal flat sediment, and emended description of the genus Alishewanella
The genus Alishewanella, proposed by Fonnesbech Strain B11 T was isolated from tidal flat sediment in Yeosu (34 u 479 260 N 127 u 349 010 E), Republic of Korea. The strain was isolated on R2A agar (Difco) followed by repeated restreaking to obtain a pure culture. The Gram reaction was determined according to the non-staining method described by T and closely related strains. Chromosomal DNA was extracted and purified using a DNA extraction kit (IntronBiotechnology). The G+C content was determined using HPLC as described by T is affiliated phylogenetically with A. fetalis; this affiliation is supported by high bootstrap values (100, 98 and 94 % by the neighbour-joining, maximum-parsimony and maximum-likelihood methods, respectively). Similarities between the 16S rRNA gene sequence of strain B11 T and those of A. fetalis CCUG 30811 T Rheinheimera aquimaris SW-353 T and Rheinheimera perlucida BA131 T were 98.3, 96.5 and 96.4 %, respectively. A DNA-DNA hybridization experiment was performed as described previously For quantitative analysis of cellular fatty acids, strain B11 T and A. fetalis CCUG 30811 T were grown under the same conditions on blood agar plates at 30 u C for 2 days. Cells were harvested and cellular fatty acids were saponified, methylated and extracted as described by the Sherlock Microbial Identification System T were C 18 : 1 v7c, C 17 : 1 v8c, summed feature 3 (C 16 : 1 v7c and/or iso-C 15 : 0 2-OH), C 16 : 0 and C 17 : 0 . Complete fatty acid compositions of the novel strain and A. fetalis CCUG 30811 T are shown in T and the type strain of A. fetalis are similar. In addition to 16S rRNA gene similarity, the major fatty acid components of strain B11 T and its temperature range for growth confirm affiliation of this strain with the genus Alishewanella
Are There Advantages in Cervical Intrafacetal Fusion With Minimal Posterolateral Fusion (PLF) Compared to Conventional PLF in Posterior Cervical Fusion?
Objective We propose that cervical intrafacetal fusion (cIFF) using bone chip insertion into the facetal joint space additional to minimal PLF is a supplementary fusion method to conventional posterolateral fusion (PLF). Methods Patients who underwent posterior cervical fixation accompanied by cIFF with minimal PLF or conventional PLF for cervical myelopathy from 2012 to 2023 were investigated retrospectively. Radiological parameters including Cobb angle and C2–7 sagittal vertical axis (SVA) were compared between the 2 groups. In cIFF with minimal PLF group, cIFF location and PLF location were carefully divided, and the fusion rates of each location were analyzed by computed tomography scan. Results Among enrolled 46 patients, 31 patients were in cIFF group, 15 in PLF group. The postoperative change of Cobb angle in 1-year follow-up in cIFF with minimal PLF group and conventional PLF group were 0.1° ± 4.0° and -9.7° ± 8.4° respectively which was statistically lower in cIFF with minimal PLF group (p = 0.022). Regarding the fusion rate in cIFF with minimal PLF group in postoperative 6 months, the rates was achieved in 267 facets (98.1%) in cIFF location, and 244 facets (89.7%) in PLF location (p < 0.001). Conclusion Postoperative sagittal alignment was more preserved in cIFF with minimal PLF group compared with conventional PLF group. Additionally, in cIFF with minimal PLF group, the bone fusion rate of cIFF location was higher than PLF location. Considering the concerns of bone chip migration onto the spinal cord and relatively low fusion rate in PLF method, applying cIFF method using minimized PLF might be a beneficial alternative for posterior cervical decompression and fixation
Sacropelvic Fixation for Adult Deformity Surgery Comparing Iliac Screw and Sacral 2 Alar-Iliac Screw Fixation: Systematic Review and Updated Meta-Analysis
Objective Two commonly used techniques for spinopelvic fixation in adult deformity surgery are iliac screw (IS) and sacral 2 alar-iliac screw (S2AI) fixations. In this article, we systematically meta-analyzed the complications of sacropelvic fixation for adult deformity surgery comparing IS and S2AI. Methods The PubMed, Embase, Web of Science, and Cochrane clinical trial databases were systematically searched until March 29, 2023. The proportion of postoperative complications, including implant failure, revision, screw prominence, and wound complications after sacropelvic fixation, were pooled with a random-effects model. Subgroup analyses for the method of sacropelvic fixation were conducted. Results Ten studies with a total of 1,931 patients (IS, 925 patients; S2AI, 1,006 patients) were included. The pooled proportion of implant failure was not statistically different between the IS and S2AI groups (21.9% and 18.9%, respectively) (p = 0.59). However, revision was higher in the IS group (21.0%) than that in the S2AI group (8.5%) (p = 0.02). Additionally, screw prominence was higher in the IS group (9.6%) than that in the S2AI group (0.0%) (p < 0.01), and wound complication was also higher in the IS group (31.7%) than that in the S2AI group (3.9%) (p < 0.01). Conclusion IS and S2AI fixations showed that both techniques had similar outcomes in terms of implant failure. However, S2AI was revealed to have better outcomes than IS in terms of revision, screw prominence, and wound complications
- …