4 research outputs found

    Development of a high-accuracy, low-cost, and portable fluorometer with smartphone application for the detection of urinary albumin towards the early screening of chronic kidney and renal diseases

    Get PDF
    This study presents the development of a portable fluorometer with a smartphone application designed to facilitate the early screening of chronic kidney and renal diseases by enabling the sensitive detection of urinary albumin. Utilizing a fluorescence-based aptasensor, the device achieved a linear calibration curve (0.001–1.5 mg/mL) with a linearity of up to 0.98022 and a detection limit of 0.203 µg/mL for human serum albumin (HSA). The analysis of 130 urine samples demonstrated comparable performance between this study’s fluorometer, a commercial fluorometer, and the standard automated method. These findings validate the feasibility of the portable fluorometer and aptasensor combination as a reliable instrument for the sensitive and specific measurement of HSA in urine samples. Moreover, the fluorometer’s portability offers potential applications in portable point-of-care testing, enhancing its utility in clinical settings for early disease screening

    Immobilization-Free Electrochemical Sensor Coupled with a Graphene-Oxide-Based Aptasensor for Glycated Albumin Detection

    No full text
    An immobilization-free electrochemical sensor coupled with a graphene oxide (GO)-based aptasensor was developed for glycated human serum albumin (GHSA) detection. The concentration of GHSA was monitored by measuring the electrochemical response of free GO and aptamer-bound GO in the presence of glycated albumin; their currents served as the analytical signals. The electrochemical aptasensor exhibited good performance with a base-10 logarithmic scale. The calibration curve was achieved in the range of 0.01–50 µg/mL. The limit of detection (LOD) was 8.70 ng/mL. The developed method was considered a one-drop measurement process because a fabrication step and the probe-immobilization process were not required. This simple sensor offers a cost-effective, rapid, and sensitive detection method, and could be an alternative approach for determination of GHSA levels

    Effects of Boric Acid and Storage Temperature on the Analysis of Microalbumin Using Aptasensor-Based Fluorescent Detection

    No full text
    The instability of human serum albumin (HSA) in urine samples makes fresh urine a requirement for microalbumin analyses using immunoturbidimetry. Here, we determined the ability of an aptasensor-based fluorescent platform to detect microalbumin in old, boric acid-preserved urine samples. Our results show that the cleavage site of protease enzymes on urine albumin protein differed from the binding position of the aptamer on HSA protein, suggesting the aptasensor may be effective for albumin detection in non-fresh urine. Furthermore, the addition of boric acid in urine samples over a short term (at ambient temperature (Ta) and 4 °C), long term (−20 and −80 °C), and following freeze–thawing (1–3 cycles) did not significantly affect albumin stability, as analyzed using the aptasensor. Therefore, boric acid stabilized has in urine stored over a short- and long-term. Thus, the aptasensor developed by us is applicable for HSA detection in boric acid-preserved urine that has been stored for 7-d at Ta and 4 °C, and in the long-term at −80 °C

    Albuminuria detection using graphene oxide-mediated fluorescence quenching aptasensor

    Get PDF
    A simple and sensitive graphene oxide-mediated fluorescence quenching aptasensor is developed to quantify albuminuria in urine samples. The developed aptasensor used the specific target binding property of aptamer and fluorescence quenching property of graphene oxide to determine the concentration of human serum albumin in urine. The limit of detection of the developed platform is 0.05 µg.mL−1 and the detection range is 0.1–600 µg.mL−1, which covers the albuminuria concentration range present in normal human urine and the urine of the patient with chronic kidney disease. This approach can be modified to measure albuminuria using a high-throughput quantification platform and portable point of care testing. In addition, the production cost for one reaction is cheaper than those for the standard automated method. Therefore, this aptasensor has significant potential for commercialization and public use. Our protocol is customized by using the fluorescence quenching property of graphene oxide and specific binding property of human serum albumin aptamer to detect human serum albumin in urine sample. The limit of detection of our developed platform is 0.05 µg.mL−1. The detection range of our aptasensor is 0.1–600 µg.mL−
    corecore