46 research outputs found
Paxillin Dynamics Measured during Adhesion Assembly and Disassembly by Correlation Spectroscopy
Paxillin is an adaptor molecule involved in the assembly of focal adhesions. Using different fluorescence fluctuation approaches, we established that paxillin-EGFP is dynamic on many timescales within the cell, ranging from milliseconds to seconds. In the cytoplasmic regions, far from adhesions, paxillin is uniformly distributed and freely diffusing as a monomer, as determined by single-point fluctuation correlation spectroscopy and photon-counting histogram analysis. Near adhesions, paxillin dynamics are reduced drastically, presumably due to binding to protein partners within the adhesions. The photon-counting histogram analysis of the fluctuation amplitudes reveals that this binding equilibrium in new or assembling adhesions is due to paxillin monomers binding to quasi-immobile structures, whereas in disassembling adhesions or regions of adhesions, the equilibrium is due to exchange of large aggregates. Scanning fluctuation correlation spectroscopy and raster-scan image correlation spectroscopy analysis of laser confocal images show that the environments within adhesions are heterogeneous. Relatively large adhesions appear to slide transversally due to a treadmilling mechanism through the addition of monomeric paxillin at one side and removal of relatively large aggregates of proteins from the retracting edge. Total internal reflection microscopy performed with a fast acquisition EM-CCD camera completes the overall dynamic picture and adds details of the heterogeneous dynamics across single adhesions and simultaneous bursts of activity at many adhesions across the cell
Spatiotemporal image correlation spectroscopy measurements of flow demonstrated in microfluidic channels.
Accurate blood flow measurements during surgery can improve an operation's chance of success. We developed near-infrared spatio-temporal image spectroscopy (NIR-STICS), which has the potential to make blood flow measurements that are difficult to accomplish with existing methods. Specifically, we propose the technique and we show feasibility on phantom measurements. NIR-STICS has the potential of measuring the fluid velocity in small blood vessels (less than 1 mm in diameter) and of creating a map of blood flow rates over an area of approximately 1 cm(2). NIR-STICS employs near-infrared spectroscopy to probe inside blood vessel walls and spatiotemporal image correlation spectroscopy to directly-without the use of a model-extract fluid velocity from the fluctuations within an image. We present computer simulations and experiments on a phantom system that demonstrate the effectiveness of NIR-STICS
Recommended from our members
Spatiotemporal image correlation spectroscopy measurements of flow demonstrated in microfluidic channels.
Accurate blood flow measurements during surgery can improve an operation's chance of success. We developed near-infrared spatio-temporal image spectroscopy (NIR-STICS), which has the potential to make blood flow measurements that are difficult to accomplish with existing methods. Specifically, we propose the technique and we show feasibility on phantom measurements. NIR-STICS has the potential of measuring the fluid velocity in small blood vessels (less than 1 mm in diameter) and of creating a map of blood flow rates over an area of approximately 1 cm(2). NIR-STICS employs near-infrared spectroscopy to probe inside blood vessel walls and spatiotemporal image correlation spectroscopy to directly-without the use of a model-extract fluid velocity from the fluctuations within an image. We present computer simulations and experiments on a phantom system that demonstrate the effectiveness of NIR-STICS
Scanning laser image correlation for measurement of flow
Scanning laser image correlation (SLIC) is an optical correlation technique for measuring the fluid velocity of particles suspended in a liquid. This technique combines laser scanning of an arbitrary pattern with pair cross-correlation between any two points in the pattern. SLIC overcomes many of the limitations of other optical correlation techniques for flow measurement, such as laser speckle, spatial temporal image correlation spectroscopy, and two-foci methods. One of the main advantages of SLIC is that the concept can be applied to measurements on a range of scales through simple zooming or modifications in the instrumentation. Additionally, SLIC is relatively insensitive to instrument noise through the use of correlation analysis and is insensitive to background. SLIC can provide detailed information about the direction and pattern of flow. SLIC has potential applications ranging from microfluidics to blood flow measurements
Recommended from our members
Scanning laser image correlation for measurement of flow.
Scanning laser image correlation (SLIC) is an optical correlation technique for measuring the fluid velocity of particles suspended in a liquid. This technique combines laser scanning of an arbitrary pattern with pair cross-correlation between any two points in the pattern. SLIC overcomes many of the limitations of other optical correlation techniques for flow measurement, such as laser speckle, spatial temporal image correlation spectroscopy, and two-foci methods. One of the main advantages of SLIC is that the concept can be applied to measurements on a range of scales through simple zooming or modifications in the instrumentation. Additionally, SLIC is relatively insensitive to instrument noise through the use of correlation analysis and is insensitive to background. SLIC can provide detailed information about the direction and pattern of flow. SLIC has potential applications ranging from microfluidics to blood flow measurements
Recommended from our members
An optical technique for fluid velocity measurement applicable to intra-operative blood flow
Recommended from our members