21 research outputs found
Noroviruses in Archival Samples
Application of recent techniques to detect current pathogens in archival effluent samples collected and concentrated in 1987 lead to the characterization of norovirus GGII.6 Seacroft, unrecognized until 1990 in a clinical sample. Retrospective studies will likely increase our knowledge about waterborne transmission of emerging pathogens
Sources of Hepatitis E Virus Genotype 3 in the Netherlands
Four subtypes have been detected, and pathogenicity, zoonotic potential, or stability may vary between subtypes
Long-term wastewater monitoring of SARS-CoV-2 viral loads and variants at the major international passenger hub Amsterdam Schiphol Airport: A valuable addition to COVID-19 surveillance
Wastewater-based epidemiological surveillance at municipal wastewater treatment plants has proven to play an important role in COVID-19 surveillance. Considering international passenger hubs contribute extensively to global transmission of viruses, wastewater surveillance at this type of location may be of added value as well. The aim of this study is to explore the potential of long-term wastewater surveillance at a large passenger hub as an additional tool for public health surveillance during different stages of a pandemic. Here, we present an analysis of SARS-CoV-2 viral loads in airport wastewater by reverse-transcription quantitative polymerase chain reaction (RT-qPCR) from the beginning of the COVID-19 pandemic in Feb 2020, and an analysis of SARS-CoV-2 variants by whole-genome next-generation sequencing from Sep 2020, both until Sep 2022, in the Netherlands. Results are contextualized using (inter)national measures and data sources such as passenger numbers, clinical surveillance data and national wastewater surveillance data. Our findings show that wastewater surveillance was possible throughout the study period, irrespective of measures, as viral loads were detected and quantified in 98.6 % (273/277) of samples. Emergence of SARS-CoV-2 variants, identified in 91.0 % (161/177) of sequenced samples, coincided with increases in viral loads. Furthermore, trends in viral load and variant detection in airport wastewater closely followed, and in some cases preceded, trends in national daily average viral load in wastewater and variants detected in clinical surveillance. Wastewater-based epidemiology at a large international airport is a valuable addition to classical COVID-19 surveillance and the developed expertise can be applied in pandemic preparedness plans for other (emerging) pathogens in the future
Patterns of SARS-CoV-2 circulation revealed by a nationwide sewage surveillance programme, the Netherlands, August 2020 to February 2022
BackgroundSurveillance of SARS-CoV-2 in wastewater offers a near real-time tool to track circulation of SARS-CoV-2 at a local scale. However, individual measurements of SARS-CoV-2 in sewage are noisy, inherently variable and can be left-censored.AimWe aimed to infer latent virus loads in a comprehensive sewage surveillance programme that includes all sewage treatment plants (STPs) in the Netherlands and covers 99.6% of the Dutch population.MethodsWe applied a multilevel Bayesian penalised spline model to estimate time- and STP-specific virus loads based on water flow-adjusted SARS-CoV-2 qRT-PCR data for one to four sewage samples per week for each of the more than 300 STPs.ResultsThe model captured the epidemic upsurges and downturns in the Netherlands, despite substantial day-to-day variation in the measurements. Estimated STP virus loads varied by more than two orders of magnitude, from ca 1012 virus particles per 100,000 persons per day in the epidemic trough in August 2020 to almost 1015 per 100,000 in many STPs in January 2022. The timing of epidemics at the local level was slightly shifted between STPs and municipalities, which resulted in less pronounced peaks and troughs at the national level.ConclusionAlthough substantial day-to-day variation is observed in virus load measurements, wastewater-based surveillance of SARS-CoV-2 that is performed at high sampling frequency can track long-term progression of an epidemic at a local scale in near real time
Aichi Virus in Sewage and Surface Water, the Netherlands
Detection of Aichi virus in humans was initially reported in Japan in 1989. To establish a timeline for the prevalence of Aichi virus infection among humans in the Netherlands, we conducted molecular analysis of archival water samples from 1987–2000 and 2009–2012. Aichi virus RNA was detected in 100% (8/8) of sewage samples and 100% (7/7) of surface water samples collected during 1987–2000 and 100% (8/8) of sewage samples and 71% (5/7) of surface water samples collected during 2009–2012. Several genotype A and B Aichi virus lineages were observed over the 25-year period studied, but the time course of viral genetic diversity showed recent expansion of the genotype B population over genotype A. Our results show that Aichi virus has been circulating among the human population in the Netherlands since before its initial detection in humans was reported and that genotype B now predominates in this country
Real-time detection of noroviruses in surface water by use of a broadly reactive nucleic acid sequence-based amplification assay.
Noroviruses are the most common agents causing outbreaks of viral gastroenteritis. Outbreaks originating from contaminated drinking water and from recreational waters have been described. Due to a lack of cell culture systems, noroviruses are detected mostly by molecular methods. Molecular detection assays for viruses in water are often repressed by inhibitory factors present in the environment, like humic acids and heavy metals. To study the effect of environmental inhibitors on the performance of nucleic acid sequence-based amplification (NASBA), we developed a real-time norovirus NASBA targeting part of the RNA-dependent RNA polymerase (RdRp) gene. Specificity of the assay was studied with 33 divergent clones that contained part of the targeted RdRp gene of noroviruses from 15 different genogroups. Viral RNA originated from commercial oysters, surface waters, and sewage treatment plants in The Netherlands. Ninety-seven percent of the clones derived from human noroviruses were detected by real-time NASBA. Two clones containing animal noroviruses were not detected by NASBA. We compared the norovirus detection by real-time NASBA with that by conventional reverse transcriptase PCR (RT-PCR) with large-volume river water samples and found that inhibitory factors of RT-PCR had little or no effect on the performance of the norovirus NASBA. This consequently resulted in a higher sensitivity of the NASBA assay than of the RT-PCR. We show that by combining an efficient RNA extraction method with real-time NASBA the sensitivity of norovirus detection in water samples increased at least 100 times, which consequently has implications for the outcome of the infectious risk assessment
Isolation and Detection of Enterovirus RNA from Large-Volume Water Samples by Using the NucliSens miniMAG System and Real-Time Nucleic Acid Sequence-Based Amplification
Concentration of water samples is a prerequisite for the detection of the low virus levels that are present in water and may present a public health hazard. The aim of this study was to develop a rapid, standardized molecular method for the detection of enteroviruses in large-volume surface water samples, using a concentration method suitable for the detection of infectious viruses as well as virus RNA. Concentration of water was achieved by a conventional filter adsorption-elution method and ultrafiltration, resulting in a 10,000-fold concentration of the sample. Isolation of virus RNA by a silica-based RNA extraction method was compared with the nonmagnetic and magnetic NucliSens RNA isolation methods. By using the silica-based RNA extraction method in two out of five samples, enterovirus RNA was detected, whereas four out of five samples were positive following RNA isolation with magnetic silica beads. Moreover, estimated RNA levels increased at least 100 to 500 times. Furthermore, we compared enterovirus detection by an in-house reverse transcription (RT)-PCR with a novel commercially available real-time nucleic acid sequence-based amplification (NASBA) assay. We found that the rapid real-time NASBA assay was slightly less sensitive than our in-house RT-PCR. The advantages, however, of a commercial real-time NASBA assay, like the presence of an internal control RNA, standardization, and enormous decrease in turnaround time, makes it an attractive alternative to RT-PCR