    List-Mode Maximum Likelihood Reconstruction of Compton Scatter Camera Images in Nuclear Medicine

    Full text link
    A Maximum Likelihood (ML) image reconstruction technique using list-mode data has been applied to Compton scattering camera imaging. List-mode methods are appealing in Compton camera image reconstruction because the total number of data elements in the list (the number of detected photons) is significantly smaller than the number of possible combinations of position and energy measurements, leading to a much smaller problem than that faced by traditional iterative reconstruction techniques. For a realistic size device, the number of possible detector bins can be as large as 10 billion per pixel of the image space, while the number of counted photons would typically be a very small fraction of that. The primary difficulty in applying the list-mode technique is in determining the parameters which describe the response of the imaging system. In this work, a simple method for determining the required system matrix coefficients is employed, in which a back-projection is performed in list-mode, and response coefficients determined for only tallied pixels. Projection data has been generated for a representative Compton camera system by Monte Carlo simulation for disk sources with hot and cold spots and energies of 141, 364, and 511 keV, and reconstructions performed.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/85815/1/Fessler155.pd

    Relativistic electron beam propagation in the Earth's atmosphere: Modeling results

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/95662/1/grl8999.pd

    Improved Modeling of System Response in List Mode EM Reconstruction of Compton Scatter Camera Images

    Full text link
    An improved List Mode EM method for reconstructing Compton scattering camera images has been developed. First, an approximate method for computation of the spatial variation in the detector sensitivity has been derived and validated by Monte Carlo computation. A technique for estimating the relative weight of system matrix coefficients for each gamma in the list has also been employed, as has a method for determining the relative probabilities of emission having some from pixels tallied in each list-mode back-projection. Finally, a technique has been developed for modeling the effects of Doppler broadening and finite detector energy resolution on the relative weights for pixels neighbor to those intersected by the back-projection, based on values for the FWHM of the spread in the cone angle computed by Monte Carlo. Memory issues typically associated with list mode reconstruction are circumvented by storing only a list of the pixels intersected by the back-projections, and computing the weights of the neighboring pixels at each iteration step. Simulated projection data has been generated for a representative Compton camera system (CSPRINT) for several source distributions and reconstructions performed. Reconstructions have also been performed for experimental data for distributed sources.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/86027/1/Fessler157.pd

    Improved Modeling of System Response in List Mode EM Reconstruction of Compton Scatter Camera Images

    Full text link
    An improved List Mode EM method for reconstructing Compton scattering camera images has been developed. First, an approximate method for computation of the spatial variation in the detector sensitivity has been derived and validated by Monte Carlo computation. A technique for estimating the relative weight of system matrix coefficients for each gamma in the list has also been employed, as has a method for determining the relative probabilities of emission having come from pixels tallied in each list-mode back-projection. Finally, a technique has been developed for modeling the effects of Doppler broadening and finite detector energy resolution on the relative weights for pixels neighbor to those intersected by the back-projection, based on values for the FWHM of the spread in the cone angle computed by Monte Carlo. Memory issues typically associated with list mode reconstruction are circumvented by storing only a list of the pixels intersected by the back-projections, and computing the weights of the neighboring pixels at each iteration step. Reconstructions have been performed on experimental data for both point and distributed sourcesPeer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/86026/1/Fessler77.pd

    List Mode EM Reconstruction of Compton Scatter Camera Images in 3-D

    Full text link
    A method has been developed for List Mode EM reconstruction of Compton scattering camera images in 3D, using a previously reported 2-D technique and refining and adapting it to three dimensions. Spatial variation in the system sensitivity is determined by an approximate numerical integration which accounts for solid angle effects, absorption and escape probabilities, and variation in the differential angular scattering cross section. The method for computing the system transition probabilities uses a similar method to determine values in pixels along exact back-projected cones for each detected event, and uses pre-computed values of the inherent system resolution (which includes the effects of spatial and energy measurement resolution and Doppler broadening) to model the response in pixels neighboring the back-projected cone. The algorithm has been parallelized, permitting reconstruction of images using larger number of detected events in relatively constant time by adding additional processors. Results are presented using 3-D simulated data.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/85814/1/Fessler162.pd

    Biological-Effect Modeling of Radioimmunotherapy for Non-Hodgkins Lymphoma: Determination of Model Parameters

    Full text link
    Treatment with Tositumomab and 131I tositumomab anti-CD20 radioimmunotherapy (Bexxar) yields a nonradioactive antibody antitumor response (the so-called cold effect) and a radiation response. Numerical parameter determination by least-squares (LS) fitting was implemented for more accurate parameter estimates in equivalent biological-effect calculations. Methods: One hundred thirty-two tumors in 37 patients were followed using five or six SPECT/CT studies per patient, three each (typical) post-tracer (0.2 GBq) and post-therapy (?3 GBq) injections. The SPECT/CT data were used to calculate position- and time-dependent dose rates and antibody concentrations for each tumor. CT-defined tumor volumes were used to track tumor volume changes. Combined biological-effect and cell-clearance models were fit to tumor volume changes. Optimized parameter values determined using LS fitting were compared to previous fitted values that were determined by matching calculated to measured tumor volume changes using visual assessment. Absorbed dose sensitivity (α) and cold-effect sensitivity (?p) parameters were the primary fitted parameters, yielding equivalent biological-effect (E) values. Results: Individual parameter uncertainties were approximately 10% and 30% for α and ?p, respectively. LS versus previously fit parameter values were highly correlated, although the averaged α value decreased and the averaged ?p value increased for the LS fits compared to the previous fits. Correlation of E with 2-month tumor shrinkage data was similar for the two fitting techniques. The LS fitting yielded improved fit quality and likely improved parameter estimation.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/140326/1/cbr.2012.1467.pd

    A vectorized Monte Carlo detector simulation program for electromagnetic interactions

    Full text link
    MC4 is a detector simulation program combining a vectorized ray-tracing algorithm with a vectorized version of the electromagnetic interaction routines from GEANT3. The implementation of ray tracing is able to represent moderately complex geometries such as single calorimeter modules or test-beam situations. Results from MC4 are compared with EGS4 simulations and with experimental results. Timing results are given for scalar machines and on a vector supercomputer. Production applications and applications to future versions of the GEANT code are discussed.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/27643/1/0000019.pd

    Microfocus X-ray sources for 3D microtomography

    Full text link
    An analytic model for the performance of cone beam microtomography is described. The maximum power of a microfocus X-ray source is assumed to be approximately proportional to the focal spot size. Radiation flux penetrating the specimen is predicted by a semi-empirical relation which is valid for X-ray energies less than 20 keV. Good signal to noise ratio is predicted for bone specimens of 0.1 to 10 mm when scanned at the optimal energy. A flux of about 1 x 1010 photons/mm2/s is identified for 0.2 mm specimens. Cone beam volumetric microtomography is found to compare favorably with synchrotron based methods.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/31116/1/0000012.pd
    • 