5 research outputs found

    Serum S100B levels after meningioma surgery: A comparison of two laboratory assays

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>S100B protein is a potential biomarker of central nervous system insult. This study quantitatively compared two methods for assessing serum concentration of S100B.</p> <p>Methods</p> <p>A prospective, observational study performed in a single tertiary medical center. Included were fifty two consecutive adult patients undergoing surgery for meningioma that provided blood samples for determination of S100B concentrations. Eighty samples (40 pre-operative and 40 postoperative) were randomly selected for batch testing. Each sample was divided into two aliquots. These were analyzed by ELISA (Sangtec) and a commercial kit (Roche Elecsys<sup>®</sup>) for S100B concentrations. Statistical analysis included regression modelling and Bland-Altman analysis.</p> <p>Results</p> <p>A parsimonious linear model best described the prediction of commercial kit values by those determined by ELISA (y = 0.045 + 0.277*x, x = ELISA value, R<sup>2 </sup>= 0.732). ELISA measurements tended to be higher than commercial kit measurements. This discrepancy increased linearly with increasing S100B concentrations. At concentrations above 0.7 μg/L the paired measurements were consistently outside the limits of agreement in the Bland-Altman display. Similar to other studies that used alternative measurement methods, sex and age related differences in serum S100B levels were not detected using the Elecsys<sup>® </sup>(p = 0.643 and 0.728 respectively).</p> <p>Conclusion</p> <p>Although a generally linear relationship exists between serum S100B concentrations measured by ELISA and a commercially available kit, ELISA values tended to be higher than commercial kit measurements particularly at concentrations over 0.7 μg/L, which are suggestive of brain injury. International standardization of commercial kits is required before the predictive validity of S100B for brain damage can be effectively assessed in clinical practice.</p

    S100 protein in serum as a prognostic marker for cerebral injury in term newborn infants with hypoxic ischemic encephalopathy

    No full text
    The astroglial protein S100 is an established biochemical marker for CNS injury in the adult. The aim was to investigate whether S100 in serum is a prognostic marker of cerebral injury in term newborn infants, with hypoxic ischemic encephalopathy (HIE) after perinatal asphyxia. Serum S100 was measured on postnatal days 1-4 in 62 term infants with birth asphyxia. The infants were classified for HIE and had follow-up for at least 18 mo. Infants with moderate and severe HIE had significantly higher S100 levels on postnatal day 1 (p = 0.031) and day 2 (p = 0.008) than infants with mild or no HIE. The levels of S100 decreased on days 2 and 3 in all infants with HIE. The median S 100 level on postnatal day I was higher in nine infants who died neonatally and in 10 infants who developed cerebral palsy (CP), compared with 43 infants with no signs of impairment at follow up, 14.0 (0.5-60.0) mug/L, 20.7 (0.2-64.0) mug/L and 5.5 (0.7-120.0) mug/L, respectively. A level of S100 above 12 mug/L the first day of life was significantly more trequent in infants who died or developed CP than in infants with no impairment at follow LIP (P = 0.02). Increased S100 levels were significantly inversely correlated with perinatal pH in the infants and associated with abnormal CTG at admission to the labor ward. Early determination of serum S100 may reflect the extent of brain damage in infants with HIE after asphyxia

    Consequences of Intrauterine Growth Restriction for the Kidney

    No full text
    corecore