14 research outputs found

    A Social Media mHealth Solution to Address the Needs of Dengue Prevention and Management in Sri Lanka

    Get PDF
    Background: Sri Lanka has witnessed a series of dengue epidemics over the past five years, with the western province, home to the political capital of Colombo, bearing more than half of the dengue burden. Existing dengue monitoring prevention programs are exhausted as public health inspectors (PHIs) cope with increasing workloads and paper-based modes of surveillance and education, characterizing a reactive system unable to cope with the enormity of the problem. On the other hand, the unprecedented proliferation and affordability of mobile phones since 2009 and a supportive political climate have thus far remained unexploited for the use of mobile-based interventions for dengue management. Objective: To conduct a needs assessment of PHIs in Colombo with respect to their dengue-related tasks and develop a new mobile-based system to address these needs while strengthening existing systems. Methods: One-on-one in-depth interviews were conducted with 29 PHIs to a) gain a nuanced, in-depth understanding of the current state of surveillance practices, b) understand the logistical, technological and social challenges they confront, and c) identify opportunities for mobile-based interventions. Quantitative analysis included simple descriptive statistics while qualitative analysis comprised textual analysis of 209 pages of transcripts (or nearly 600 minutes of conversations) using grounded theory approaches. Results: Current paper-based data collection practices for dengue surveillance involved a circuitous, time consuming process that could take between 7-10 days to officially report and record a single case. PHIs confronted challenges in terms of unreliable, standalone GIS devices, delays in registering mosquito breeding sites and lack of engagement from communities while delivering dengue education. These findings, in concert with a high motivation to use mobile-based systems, informed the development of Mo-Buzz, a mobile-based system that integrates three components – digitized surveillance, dynamic disease mapping and digitized dengue education – on a common platform. The system was developed through an iterative, evolutionary, collaborative process, consistent with the Spiral model of software development and is currently being used by all 55 PHIs in the CMC system. Conclusions: Given the entrenched nature of existing paper-based systems in PHIs’ work habits, we expect a gradual adoption curve for Mo-Buzz in the future. Equally, we expect variable adoption of the system with respect to its specific components, and specific PHI sub-groups (younger versus older). The Mo-Buzz intervention is a response to multiple calls by the global mHealth community for collaborations in the area of mobile interventions for global health. Our experience revealed that the benefits of this paradigm lies in alleviating country-specific public health challenges through a commonly shared understanding of cultural mores, and sharing of knowledge and technologies. We call upon future researchers to further dissect the applicability of the Spiral Model of software development to mHealth interventions and contribute to the mHealth evidence debate from theoretical and applied perspectives

    Comparison of different sequencing techniques for identification of SARS-CoV-2 variants of concern with multiplex real-time PCR

    Get PDF
    As different SARS-CoV-2 variants emerge and with the continuous evolvement of sub lineages of the delta variant, it is crucial that all countries carry out sequencing of at least >1% of their infections, in order to detect emergence of variants with higher transmissibility and with ability to evade immunity. However, due to limited resources as many resource poor countries are unable to sequence adequate number of viruses, we compared to usefulness of a two-step commercially available multiplex real-time PCR assay to detect important single nucleotide polymorphisms (SNPs) associated with the variants and compared the sensitivity, accuracy and cost effectiveness of the Illumina sequencing platform and the Oxford Nanopore Technologies’ (ONT) platform. 138/143 (96.5%) identified as the alpha and 36/39 (92.3%) samples identified as the delta variants due to the presence of lineage defining SNPs by the multiplex real time PCR, were assigned to the same lineage by either of the two sequencing platforms. 34/37 of the samples sequenced by ONT had <5% ambiguous bases, while 21/37 samples sequenced using Illumina generated <5%. However, the mean PHRED scores averaged at 32.35 by Illumina reads but 10.78 in ONT. This difference results in a base error probability of 1 in 10 by the ONT and 1 in 1000 for Illumina sequencing platform. Sub-consensus single nucleotide variations (SNV) are highly correlated between both platforms (R2 = 0.79) while indels appear to have a weaker correlation (R2 = 0.13). Although the ONT had a slightly higher error rate compared to the Illumina technology, it achieved higher coverage with a lower number or reads, generated less ambiguous bases and was significantly less expensive than Illumina sequencing technology

    SARS-CoV-2 neutralizing antibodies in patients with varying severity of acute COVID-19 illness

    Get PDF
    In order to support vaccine development, and to aid convalescent plasma therapy, it would be important to understand the kinetics, timing and persistence of SARS-CoV-2 neutralizing antibodies (NAbs), and their association with clinical disease severity. Therefore, we used a surrogate viral neutralization test to evaluate their levels in patients with varying severity of illness, in those with prolonged shedding and those with mild/asymptomatic illness at various time points. Patients with severe or moderate COVID-19 illness had earlier appearance of NAbs at higher levels compared to those with mild or asymptomatic illness. Furthermore, those who had prolonged shedding of the virus, had NAbs appearing faster and at higher levels than those who cleared the virus earlier. During the first week of illness the NAb levels of those with mild illness was significantly less (p = 0.01), compared to those with moderate and severe illness. At the end of 4 weeks (28 days), although 89% had NAbs, 38/76 (50%) in those with > 90 days had a negative result for the presence of NAbs. The Ab levels significantly declined during convalescence (> 90 days since onset of illness), compared to 4 to 8 weeks since onset of illness. Our data show that high levels of NAbs during early illness associated with clinical disease severity and that these antibodies declined in 50% of individuals after 3 months since onset of illness

    Molecular epidemiology of AY.28 and AY.104 delta sub-lineages in Sri Lanka

    Get PDF
    Background: The worst SARS-CoV-2 outbreak in Sri Lanka was due to the two Sri Lankan delta sub-lineages AY.28 and AY.104. We proceeded to further characterize the mutations and clinical disease severity of these two sub-lineages. Methods: 705 delta SARS-CoV-2 genomes sequenced by our laboratory from mid-May to November 2021 using Illumina and Oxford Nanopore were included in the analysis. The clinical disease severity of 440/705 individuals were further analyzed to determine if infection with either AY.28 or AY.104 was associated with more severe disease. Sub-genomic RNA (sg-RNA) expression was analyzed using periscope. Results: AY.28 was the dominant variant throughout the outbreak, accounting for 67.7% of infections during the peak of the outbreak. AY.28 had three lineage defining mutations in the spike protein: A222V (92.80%), A701S (88.06%), and A1078S (92.04%) and seven in the ORF1a: R24C, K634N, P1640L, A2994V, A3209V, V3718A, and T3750I. AY.104 was characterized by the high prevalence of T95I (90.81%) and T572L (65.01%) mutations in the spike protein and by the absence of P1640L (94.28%) in ORF1a with the presence of A1918V (98.58%) mutation. The mean sgRNA expression levels of ORF6 in AY.28 were significantly higher compared to AY.104 (p < 0.0001) and B.1.617.2 (p < 0.01). Also, ORF3a showed significantly higher sgRNA expression in AY.28 compared to AY.104 (p < 0.0001). There was no difference in the clinical disease severity or duration of hospitalization in individuals infected with these sub lineages. Conclusions: Therefore, AY.28 and AY.104 appear to have a fitness advantage over the parental delta variant (B.1.617.2), while AY.28 also had a higher expression of sg-RNA compared to other sub-lineages. The clinical implications of these should be further investigated

    Sensitivity and specificity of two WHO approved SARS-CoV2 antigen assays in detecting patients with SARS-CoV2 infection

    Get PDF
    Background: SARS-CoV-2 rapid antigen (Ag) detection kits are widely used in addition to quantitative reverse transcription PCR PCR (RT-qPCR), as they are cheaper with a rapid turnaround time. As there are many concerns regarding their sensitivity and specificity, in different settings, we evaluated two WHO approved rapid Ag kits in a large cohort of Sri Lankan individuals. Methods: Paired nasopharangeal swabs were obtained from 4786 participants for validation of the SD-Biosensor rapid Ag assay and 3325 for the Abbott rapid Ag assay, in comparison to RT-qPCR. A short questionnaire was used to record symptoms at the time of testing, and blood samples were obtained from 2721 of them for detection of SARS-CoV-2 specific antibodies. Results: The overall sensitivity of the SD-Biosensor Ag kit was 36.5% and the Abbott Ag test was 50.76%. The Abbott Ag test showed specificity of 99.4% and the SD-Biosensor Ag test 97.5%. At Ct values  30 (46.1 to 82.9%). 32.1% of those who gave a positive result with the SD-Biosensor Ag test and 26.3% of those who gave positive results with the Abbott Ag test had SARS-CoV-2 antibodies at the time of detection. Conclusions: Both rapid Ag tests appeared to be highly sensitive in detecting individuals at lower Ct values, in a community setting in Sri Lanka, but it will be important to further establish the relationship to infectivity

    Transmission dynamics, clinical characteristics and sero-surveillance in the COVID-19 outbreak in a population dense area of Colombo, Sri Lanka April- May 2020

    Get PDF
    Background The transmission dynamics of SARS-CoV-2 varies depending on social distancing measures, circulating SARS-CoV-2 variants, host factors and other environmental factors. We sought to investigate the clinical and epidemiological characteristics of a SARS-CoV-2 outbreak that occurred in a highly dense population area in Colombo, Sri Lanka from April to May 2020. Methodology/principal findings We carried out RT-qPCR for SARS-CoV2, assessed the SARS-CoV-2 specific total and neutralizing antibodies (Nabs) in a densely packed, underserved settlement (n = 2722) after identification of the index case on 15th April 2020. 89/2722 individuals were detected as infected by RT-qPCR with a secondary attack rate among close contacts being 0.077 (95% CI 0.063–0.095). Another 30 asymptomatic individuals were found to have had COVID-19 based on the presence of SARS-CoV-2 specific antibodies. However, only 61.5% of those who were initially seropositive for SARS-CoV-2 had detectable total antibodies at 120 to 160 days, while only 40.6% had detectable Nabs. 74/89 (83.1%) of RT-qPCR positive individuals were completely asymptomatic and all 15 (16.9%) who experienced symptoms were classified as having a mild illness. 18 (20.2%) were between the ages of 61 to 80. 11/89 (12.4%) had diabetes, 8/89 (9%) had cardiovascular disease and 4 (4.5%) had asthma. Of the two viruses that were sequenced and were of the B.1 and B.4 lineages with one carrying the D614G mutation. Discussion/conclusion Almost all infected individuals developed mild or asymptomatic illness despite the presence of comorbid illnesses. Since the majority of those who were in this underserved settlement were not infected despite circulation of the D614G variant, it would be important to further study environmental and host factors that lead to disease severity and transmission

    Kinetics of immune responses to SARS-CoV-2 proteins in individuals with varying severity of infection and following a single dose of the AZD1222

    Get PDF
    To characterize the IgG and IgA responses to different SARS-CoV-2 proteins, we investigated the antibody responses to SARS-CoV-2 following natural infection and following a single dose of AZD1222 (Covishield), in Sri Lankan individuals. The IgG and IgA responses were assessed to S1, S2, RBD, and N proteins in patients at 4 weeks and 12 weeks since the onset of illness or following vaccination. Antibodies to the receptor-binding domain of SARS-CoV-2 wild type (WT), α, β, and λ and ACE2 (Angiotensin Converting Enzyme 2) receptor blocking antibodies were also assessed in these cohorts. For those with mild illness and in vaccines, the IgG responses to S1, S2, RBD, and N protein increased from 4 weeks to 12 weeks, while it remained unchanged in those with moderate/severe illness. In the vaccines, IgG antibodies to the S2 subunit had the highest significant rise (P < 0.0001). Vaccines had several-fold lower IgA antibodies to all the SARS-CoV-2 proteins tested than those with natural infection. At 12 weeks, the haemagglutination test (HAT) titres were significantly lower to the α in vaccines and significantly lower in those with mild illness and in vaccines to β and for λ. No such difference was seen in those with moderate/severe illness. Vaccines had significantly less IgA to SARS-CoV-2, but comparable IgG responses those with natural infection. However, following a single dose vaccines had reduced antibody levels to the VOCs, which further declined with time, suggesting the need to reduce the gap between the two doses, in countries experiencing outbreaks due to VOCs

    Seroprevalence of SARS-CoV-2 infection in the Colombo Municipality region, Sri Lanka

    Get PDF
    Background: As the Municipality Council area in Colombo (CMC) experienced the highest number of cases until the end of January 2021, in Sri Lanka, we carried out a serosurvey prior to initiation of the vaccination program to understand the extent of the SARS-CoV-2 outbreak. Methods: SARS-CoV-2 seropositivity was determined in 2,547 individuals between the ages of 10–86 years, by the Wantai total antibody ELISA. We also compared seroprevalence using the haemagglutination test (HAT) to evaluate its usefulness in carrying out serosurveys. Results: The overall seropositivity rate was 24.46%, while seropositivity by HAT was 18.90%. Although The SARS-CoV-2 infection detection rates by PCR were highest in the population between the ages of 20–60 years of age, there was no statistically significant difference in the seropositivity rates in different age groups. For instance, although the seropositivity rate was highest in the 10–20 age group (34.03%), the PCR positivity rate was 9.80%. Differences in the PCR positivity rates and seropositivity rates were also seen in 60–70-year-olds (8.90 vs. 30.4%) and in individuals >70 years (4.10 vs. 1.20%). The seropositivity rate of the females was 29.70% (290/976), which was significantly higher (p < 0.002) than in males 21.2% (333/1,571). Conclusions: A high seroprevalence rate (24.5%) was seen in all age groups in the CMC suggesting that a high level of transmission was seen during this time. The higher PCR positivity rates between the ages of 20–60 are likely to be due to increased testing carried out in the working population. Therefore, the PCR positivity rates, appear to underestimate the true extent of the outbreak and the age groups which were infected

    Kinetics of immune responses to the AZD1222/Covishield vaccine with varying dose intervals in Sri Lankan individuals

    Get PDF
    Background To understand the kinetics of immune responses with different dosing gaps of the AZD1222 vaccine, we compared antibody and T cell responses in two cohorts with two different dosing gaps. Methods Antibodies to the SARS-CoV-2 virus were assessed in 297 individuals with a dosing gap of 12 weeks, sampled 12 weeks post second dose (cohort 1) and in 77 individuals with a median dosing gap of 21.4 weeks (cohort 2) sampled 6 weeks post second dose. ACE2-blocking antibodies (ACE2-blocking Abs), antibodies to the receptor-binding domain (RBD) of variants of concern (VOC), and ex vivo T cell responses were assessed in a subcohort. Results All individuals (100%) had SARS-CoV-2-specific total antibodies and 94.2% of cohort 1 and 97.1% of cohort 2 had ACE2-blocking Abs. There was no difference in antibody titers or positivity rates in different age groups in both cohorts. The ACE2-blocking Abs (p Conclusions Both dosing schedules resulted in high antibody and T cell responses post vaccination, although those with a longer dosing gap had a higher magnitude of responses, possibly as immune responses were measured 6 weeks post second dose compared to 12 weeks post second dose

    Comparison of the immunogenicity of five COVID-19 vaccines in Sri Lanka

    Get PDF
    To determine the antibody responses elicited by different vaccines against SARS-CoV-2, we compared antibody responses in individuals 3 months post-vaccination in those who had received different vaccines in Sri Lanka. Abs to the receptor binding domain (RBD) of the ancestral (wild type) virus (WT) as well as to variants of concern (VoCs), and ACE2 blocking Abs, were assessed in individuals vaccinated with Moderna (n = 225), Sputnik V (n = 128) or Sputnik light (n = 184) and the results were compared with previously reported data on Sinopharm and AZD1222 vaccinees. A total of 99.5% of Moderna, >94% of AZD1222 or Sputnik V and >70% of Sputnik light, >60% of Sinopharm vaccine recipients, had a positive response to ACE2 blocking antibodies. The ACE2 blocking antibody levels were highest to lowest was Moderna > Sputnik V/AZD1222 (had equal levels) > Sputnik light > Sinopharm. All Moderna recipients had antibodies to the RBD of WT, alpha and beta, while positivity rates for delta variant was 80%. The positivity rates for Sputnik V vaccinees for the WT and VoCs were higher than for AZD1222 vaccinees while those who received Sinopharm had the lowest positivity rates (<16.7%). The total antibodies to the RBD were highest for the Sputnik V and AZD1222 vaccinees. The Moderna vaccine elicited the highest ACE2 blocking antibody levels followed by Sputnik V/AZD1222, while those who received Sinopharm had the lowest levels. These findings highlight the need for further studies to understand the effects on clinical outcomes
    corecore