40 research outputs found
Radiation Oncology Workforce Recruitment Survey of 2000-2010 Graduates: Is There Need for Better Physician Resource Planning?
Purpose of the Study: To survey employment and training characteristics of Canadian radiation oncology training program graduates and foreign medical graduates with Canadian radiation oncology post-graduate education or specialist certification. Methods: A 38-question, web-based survey was distributed to radiation oncologists who completed specialty training between 2000-2010. Results: Out of 256 radiation oncologists contacted, 148 completed the survey (58% response rate). Thirty-two respondents (22%) were foreign MD graduates. One-hundred and fifteen respondents (78%) undertook fellowship training after residency. Many Canadian MD graduates (77%) and foreign MD graduates (34%) had staff positions in Canada, while 11% of all respondents had staff positions outside Canada, and 21% did not have a commitment for staff employment. Of the 31 respondents without a staff position, 22 graduated from Canadian residency training in 2009 or 2010, and 21 had completed medical school training in Canada. Conclusions: The majority of respondents were successful in securing staff positions in Canada. A sizeable proportion extended training with fellowships. New graduates may have more difficulty in finding Canadian staff positions in radiation oncology in the near future. Implications for specialty training programs and for an improved national strategy for physician resource planning are discussed
Calibrating CHIME, A New Radio Interferometer to Probe Dark Energy
The Canadian Hydrogen Intensity Mapping Experiment (CHIME) is a transit
interferometer currently being built at the Dominion Radio Astrophysical
Observatory (DRAO) in Penticton, BC, Canada. We will use CHIME to map neutral
hydrogen in the frequency range 400 -- 800\,MHz over half of the sky, producing
a measurement of baryon acoustic oscillations (BAO) at redshifts between 0.8 --
2.5 to probe dark energy. We have deployed a pathfinder version of CHIME that
will yield constraints on the BAO power spectrum and provide a test-bed for our
calibration scheme. I will discuss the CHIME calibration requirements and
describe instrumentation we are developing to meet these requirements
Canadian Hydrogen Intensity Mapping Experiment (CHIME) Pathfinder
A pathfinder version of CHIME (the Canadian Hydrogen Intensity Mapping
Experiment) is currently being commissioned at the Dominion Radio Astrophysical
Observatory (DRAO) in Penticton, BC. The instrument is a hybrid cylindrical
interferometer designed to measure the large scale neutral hydrogen power
spectrum across the redshift range 0.8 to 2.5. The power spectrum will be used
to measure the baryon acoustic oscillation (BAO) scale across this poorly
probed redshift range where dark energy becomes a significant contributor to
the evolution of the Universe. The instrument revives the cylinder design in
radio astronomy with a wide field survey as a primary goal. Modern low-noise
amplifiers and digital processing remove the necessity for the analog
beamforming that characterized previous designs. The Pathfinder consists of two
cylinders 37\,m long by 20\,m wide oriented north-south for a total collecting
area of 1,500 square meters. The cylinders are stationary with no moving parts,
and form a transit instrument with an instantaneous field of view of
100\,degrees by 1-2\,degrees. Each CHIME Pathfinder cylinder has a
feedline with 64 dual polarization feeds placed every 30\,cm which
Nyquist sample the north-south sky over much of the frequency band. The signals
from each dual-polarization feed are independently amplified, filtered to
400-800\,MHz, and directly sampled at 800\,MSps using 8 bits. The correlator is
an FX design, where the Fourier transform channelization is performed in FPGAs,
which are interfaced to a set of GPUs that compute the correlation matrix. The
CHIME Pathfinder is a 1/10th scale prototype version of CHIME and is designed
to detect the BAO feature and constrain the distance-redshift relation.Comment: 20 pages, 12 figures. submitted to Proc. SPIE, Astronomical
Telescopes + Instrumentation (2014
Oral rehydration versus intravenous therapy for treating dehydration due to gastroenteritis in children: a meta-analysis of randomised controlled trials
BACKGROUND: Despite treatment recommendations from various organizations, oral rehydration therapy (ORT) continues to be underused, particularly by physicians in high-income countries. We conducted a systematic review of randomised controlled trials (RCTs) to compare ORT and intravenous therapy (IVT) for the treatment of dehydration secondary to acute gastroenteritis in children. METHODS: RCTs were identified through MEDLINE, EMBASE, CENTRAL, authors and references of included trials, pharmaceutical companies, and relevant organizations. Screening and inclusion were performed independently by two reviewers in order to identify randomised or quasi-randomised controlled trials comparing ORT and IVT in children with acute diarrhea and dehydration. Two reviewers independently assessed study quality using the Jadad scale and allocation concealment. Data were extracted by one reviewer and checked by a second. The primary outcome measure was failure of rehydration. We analyzed data using standard meta-analytic techniques. RESULTS: The quality of the 14 included trials ranged from 0 to 3 (Jadad score); allocation concealment was unclear in all but one study. Using a random effects model, there was no significant difference in treatment failures (risk difference [RD] 3%; 95% confidence intervals [CI]: 0, 6). The Mantel-Haenzsel fixed effects model gave a significant difference between treatment groups (RD 4%; 95% CI: 2, 5) favoring IVT. Based on the four studies that reported deaths, there were six in the IVT groups and two in ORT. There were no significant differences in total fluid intake at six and 24 hours, weight gain, duration of diarrhea, or hypo/hypernatremia. Length of stay was significantly shorter for the ORT group (weighted mean difference [WMD] -1.2 days; 95% CI: -2.4,-0.02). Phlebitis occurred significantly more often with IVT (number needed to treat [NNT] 33; 95% CI: 25,100); paralytic ileus occurred more often with ORT (NNT 33; 95% CI: 20,100). These results may not be generalizable to children with persistent vomiting. CONCLUSION: There were no clinically important differences between ORT and IVT in terms of efficacy and safety. For every 25 children (95% CI: 20, 50) treated with ORT, one would fail and require IVT. The results support existing practice guidelines recommending ORT as the first course of treatment in appropriate children with dehydration secondary to gastroenteritis
Receiver development for BICEP Array, a next-generation CMB polarimeter at the South Pole
A detection of curl-type (B-mode) polarization of the primary CMB would be direct evidence for the inflationary paradigm of the origin of the Universe. The Bicep/Keck Array (BK) program targets the degree angular scales, where the power from primordial B-mode polarization is expected to peak, with ever-increasing sensitivity and has published the most stringent constraints on inflation to date. Bicep Array (BA) is the Stage-3 instrument of the BK program and will comprise four Bicep3-class receivers observing at 30/40, 95, 150 and 220/270 GHz with a combined 32,000+ detectors; such wide frequency coverage is necessary for control of the Galactic foregrounds, which also produce degree-scale B-mode signal. The 30/40 GHz receiver is designed to constrain the synchrotron foreground and has begun observing at the South Pole in early 2020. By the end of a 3-year observing campaign, the full Bicep Array instrument is projected to reach σr between 0.002 and 0.004, depending on foreground complexity and degree of removal of B-modes due to gravitational lensing (delensing). This paper presents an overview of the design, measured on-sky performance and calibration of the first BA receiver. We also give a preview of the added complexity in the time-domain multiplexed readout of the 7,776-detector 150 GHz receiver
Analysis of Temperature-to-Polarization Leakage in BICEP3 and Keck CMB Data from 2016 to 2018
The Bicep/Keck Array experiment is a series of small-aperture refracting telescopes observing degree-scale Cosmic Microwave Background polarization from the South Pole in search of a primordial B-mode signature. As a pair differencing experiment, an important systematic that must be controlled is the differential beam response between the co-located, orthogonally polarized detectors. We use high-fidelity, in-situ measurements of the beam response to estimate the temperature-to-polarization (T → P) leakage in our latest data including observations from 2016 through 2018. This includes three years of Bicep3 observing at 95 GHz, and multifrequency data from Keck Array. Here we present band-averaged far-field beam maps, differential beam mismatch, and residual beam power (after filtering out the leading difference modes via deprojection) for these receivers. We show preliminary results of "beam map simulations," which use these beam maps to observe a simulated temperature (no Q/U) sky to estimate T → P leakage in our real data
Observing low elevation sky and the CMB Cold Spot with BICEP3 at the South Pole
BICEP3 is a 520 mm aperture on-axis refracting telescope at the South Pole, which observes the polarization of the cosmic microwave background (CMB) at 95 GHz to search for the B-mode signal from inflationary gravitational waves. In addition to this main target, we have developed a low-elevation observation strategy to extend coverage of the Southern sky at the South Pole, where BICEP3 can quickly achieve degree-scale E-mode measurements over a large area. An interesting E-mode measurement is probing a potential polarization anomaly around the CMB Cold Spot. During the austral summer seasons of 2018-19 and 2019-20, BICEP3 observed the sky with a flat mirror to redirect the beams to various low elevation ranges. The preliminary data analysis shows degree-scale E-modes measured with high signal-to-noise ratio
Analysis of Temperature-to-Polarization Leakage in BICEP3 and Keck CMB Data from 2016 to 2018
The Bicep/Keck Array experiment is a series of small-aperture refracting telescopes observing degree-scale Cosmic Microwave Background polarization from the South Pole in search of a primordial B-mode signature. As a pair differencing experiment, an important systematic that must be controlled is the differential beam response between the co-located, orthogonally polarized detectors. We use high-fidelity, in-situ measurements of the beam response to estimate the temperature-to-polarization (T → P) leakage in our latest data including observations from 2016 through 2018. This includes three years of Bicep3 observing at 95 GHz, and multifrequency data from Keck Array. Here we present band-averaged far-field beam maps, differential beam mismatch, and residual beam power (after filtering out the leading difference modes via deprojection) for these receivers. We show preliminary results of "beam map simulations," which use these beam maps to observe a simulated temperature (no Q/U) sky to estimate T → P leakage in our real data
Observing low elevation sky and the CMB Cold Spot with BICEP3 at the South Pole
BICEP3 is a 520 mm aperture on-axis refracting telescope at the South Pole, which observes the polarization of the cosmic microwave background (CMB) at 95 GHz to search for the B-mode signal from inflationary gravitational waves. In addition to this main target, we have developed a low-elevation observation strategy to extend coverage of the Southern sky at the South Pole, where BICEP3 can quickly achieve degree-scale E-mode measurements over a large area. An interesting E-mode measurement is probing a potential polarization anomaly around the CMB Cold Spot. During the austral summer seasons of 2018-19 and 2019-20, BICEP3 observed the sky with a flat mirror to redirect the beams to various low elevation ranges. The preliminary data analysis shows degree-scale E-modes measured with high signal-to-noise ratio
Polarization calibration of the BICEP3 CMB polarimeter at the South Pole
The BICEP3 CMB Polarimeter is a small-aperture refracting telescope located at the South Pole and is specifically designed to search for the possible signature of inflationary gravitational waves in the Cosmic Microwave Background (CMB). The experiment measures polarization on the sky by differencing the signal of co-located, orthogonally polarized antennas coupled to Transition Edge Sensor (TES) detectors. We present precise measurements of the absolute polarization response angles and polarization efficiencies for nearly all of BICEP3's ~800 functioning polarization-sensitive detector pairs from calibration data taken in January 2018. Using a Rotating Polarized Source (RPS), we mapped polarization response for each detector over a full 360 degrees of source rotation and at multiple telescope boresight rotations from which per-pair polarization properties were estimated. In future work, these results will be used to constrain signals predicted by exotic physical models such as Cosmic Birefringence