102 research outputs found
Relationship of VO2 Peak, Body Fat Percentage, and Power Output Measured During Repeated Bouts of a Wingate Protocol
The principle of specificity would indicate that being aerobically trained would not necessarily enhance performance in events relying principally on oxygen-independent metabolic pathways (i.e. “anaerobic” exercise). Body fatness may be associated with aerobic and anaerobic performance. VO2 Peak was determined with a graded cycle ergometry and, in a separate session 4 consecutive Wingate power tests (3 min recovery) in 31 males. Pearson correlations were calculated for VO2 Peak and Body Fat Percentage with Peak Power, Mean Power, Minimum Power, Fatigue Index, Peak Heart Rate, and Recovery Heart Rate. No significant correlations were found for VO2 Peak or Body Fat Percentage with Peak Power on any bout (p\u3e0.05). Significant correlations were found for VO2 Peak and Body Fat Percentage with Mean Power, Minimum Power, and Fatigue Index. Significant correlations were found for VO2 Peak with delta values of power performance and heart rates (peak and 3 min recovery). Results indicate that VO2 Peak is associated with repeated anaerobic performance, possibly due to greater capacity to recover between bouts. Body Fat Percentage was correlated with measures of power performance (strongest relationships existing in the earlier bouts), but is not strongly correlated with either the heart rate response to power performance or the change in performance over successive bouts
Reliability of Upright and Supine Power Measurements Using an Inertial Load Cycle Ergometer
Practical, reliable, and time efficient methods of measuring muscular power are desirable for both research and applied testing situations. The inertial-load cycling method (ILC; Power/Cycle, Austin, TX) requires subjects to pedal as fast as possible against the inertial load of a flywheel for only 3-5 seconds, which could help reduce the time and effort required for maximal power testing. PURPOSE: 1) To test the intramachine reliability of ILC over 3 separate sessions, 2) to compare postural stance (upright vs. supine) during testing, and 3) to compare the maximal power (Pmax) output measured using ILC to that obtained from traditional isokinetic and leg press testing. METHODS: Subjects (n = 12) were tested on 4 non-consecutive days. The following tests were done on the first day of testing: isometric knee extension, isokinetic knee extension at several speeds, isokinetic power/endurance at 180/sec (Biodex System 4), leg press maximal isometric force, and leg press power/endurance. The other 3 days consisted exclusively of ILC testing. Subjects performed 6 ILC tests in an upright position and 6 ILC tests in a supine position on each day. The starting position was counterbalanced. Mixed-effects linear modeling was used to determine if any differences existed between testing days and between upright and supine for Pmax and revolutions per minute at Pmax (RPMpk). Mixed-modeling was also used to calculate intraclass correlation coefficients (ICC) to determine the reliability of the ILC on each testing day for Pmax and RPMpk (ICCs were calculated separately for upright and supine). gKendall fs Tau a h was used to determine the association between ILC Pmax and isokinetic and leg press data. RESULTS: For Pmax, significant differences were found between days 1 and 2 (upright: p = 0.018; supine: p = 0.014) and between days 1 and 3 (upright: p = 0.001; supine: p = 0.002), but not between days 2 and 3 (upright: p = 0.422; supine: p = 0.501). Pmax ICC values were greater than or equal to 0.97 for all days in both positions. Also, no significant differences between upright and supine postures were found for Pmax. No significant differences between days were found for RPMpk; however, there was a significant posture effect (upright greater than supine). Moderate correlations were observed between ILC Pmax and isokinetic and leg press tests (upright: 0.64-0.79, supine: 0.52-0.82). CONCLUSIONS: Overall, ILC is a very reliable test. Since a significant difference was found between day 1 and the other ILC testing days, it is suggested that day 1 of ILC testing should be used as a familiarization session to allow for subject learning. No significant difference in Pmax was seen from test 3 to test 6. However, an increase of 1.3% was observed from test 4 to test 6. Therefore, although 4 tests may be sufficient for most subjects to produce Pmax, in some cases 6 tests may be required. PRACTICAL APPLICATIONS: No differences were seen in Pmax between upright and supine positions despite differing RPMpk. This suggests that ILC testing can be used to provide reliable testing both in an upright position (appropriate for athletes) and in research (e.g., bed rest) or rehabilitation settings where supine testing is necessary. Future research should evaluate whether peak power measurements obtained with the ILC are sensitive to changes such as that observed with training and de-training
Scoping review to identify potential non-antimicrobial interventions to mitigate antimicrobial resistance in commensal enteric bacteria in North American cattle production systems
A scoping review was conducted to identify modifiable non-antimicrobial factors to reduce the occurrence of antimicrobial resistance in cattle populations. Searches were developed to retrieve peer-reviewed published studies in animal, human and in vitro microbial populations. Citations were retained when modifiable non-antimicrobial factors or interventions potentially associated with antimicrobial resistance were described. Studies described resistance in five bacterial genera, species or types, and 40 antimicrobials. Modifiable non-antimicrobial factors or interventions ranged widely in type, and the depth of evidence in animal populations was shallow. Specific associations between a factor or intervention with antimicrobial resistance in a population (e.g. associations between organic systems and tetracycline susceptibility in E. coli from cattle) were reported in a maximum of three studies. The identified non-antimicrobial factors or interventions were classified into 16 themes. Most reported associations between the non-antimicrobial modifiable factors or interventions and antimicrobial resistance were not statistically significant (P > 0·05 and a confidence interval including 1), but when significant, the results were not consistent in direction (increase or decrease in antimicrobial resistance) or magnitude. Research is needed to better understand the impacts of promising modifiable factors or interventions on the occurrence of antimicrobial resistance before any recommendations can be offered or adopted
Functional Task Test: 3. Skeletal Muscle Performance Adaptations to Space Flight
The functional task test is a multi-disciplinary study investigating how space-flight induced changes to physiological systems impacts functional task performance. Impairment of neuromuscular function would be expected to negatively affect functional performance of crewmembers following exposure to microgravity. This presentation reports the results for muscle performance testing in crewmembers. Functional task performance will be presented in the abstract "Functional Task Test 1: sensory motor adaptations associated with postflight alternations in astronaut functional task performance." METHODS: Muscle performance measures were obtained in crewmembers before and after short-duration space flight aboard the Space Shuttle and long-duration International Space Station (ISS) missions. The battery of muscle performance tests included leg press and bench press measures of isometric force, isotonic power and total work. Knee extension was used for the measurement of central activation and maximal isometric force. Upper and lower body force steadiness control were measured on the bench press and knee extension machine, respectively. Tests were implemented 60 and 30 days before launch, on landing day (Shuttle crew only), and 6, 10 and 30 days after landing. Seven Space Shuttle crew and four ISS crew have completed the muscle performance testing to date. RESULTS: Preliminary results for Space Shuttle crew reveal significant reductions in the leg press performance metrics of maximal isometric force, power and total work on R+0 (p<0.05). Bench press total work was also significantly impaired, although maximal isometric force and power were not significantly affected. No changes were noted for measurements of central activation or force steadiness. Results for ISS crew were not analyzed due to the current small sample size. DISCUSSION: Significant reductions in lower body muscle performance metrics were observed in returning Shuttle crew and these adaptations are likely contributors to impaired functional tasks that are ambulatory in nature (See abstract Functional Task Test: 1). Interestingly, no significant changes in central activation capacity were detected. Therefore, impairments in muscle function in response to short-duration space flight are likely myocellular rather than neuromotor in nature
"I am becoming more and more like my eldest brother!": the relationship between older siblings, adolescent gambling severity, and the attenuating role of parents in a large-scale nationally representative survey study
The present study examined the association between having older siblings who gamble and adolescent at-risk/problem gambling and how parents (i.e., parental knowledge of their whereabouts) and peers might moderate such effects. Data were drawn from the ESPAD®Italia2012 survey (European School Survey Project on Alcohol and Other Drugs) comprising a nationally representative Italian sample of adolescents. The analysis was carried out on a subsample of 10,063 Italian students aged 15–19 years (average age = 17.10; 55 % girls) who had at least one older sibling and who had gambled at some point in their lives. Respondents’ problem gambling severity, older gambler sibling, gambler peers, parental knowledge, and socio-demographic characteristics were individually assessed. Multinomial logistic regression analyses including two- and three-way interactions were conducted. The odds of being an at-risk/problem gambler were higher among high school students with older siblings that gambled and those with peers who gambled. Higher parental knowledge (of who the adolescent was with and where they were in their leisure time) was associated with lower rates of at-risk/problem gambling. There was also an interaction between gamblers with older siblings and parental knowledge. The combination of having siblings who gambled and a greater level of parental knowledge was associated with lower levels of problem gambling. The present study confirmed the occurrence of social risk processes (older siblings and peers who gambled) and demonstrated that gambling among older siblings and peers represents an important contextual factor for increased at-risk/problem gambling. However, parental knowledge appears to be sufficient to counterbalance the influence of older siblings
Functional Task Test: 1. Sensorimotor changes Associated with Postflight Alterations in Astronaut Functional Task Performance
Space flight is known to cause alterations in multiple physiological systems including changes in sensorimotor, cardiovascular, and neuromuscular systems. These changes may affect a crewmember s ability to perform critical mission tasks immediately after landing on a planetary surface. The overall goal of this project is to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. This presentation will focus on the sensorimotor contributions to postflight functional performance
Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons
The Compact Muon Solenoid Collaboration is designing a new high-granularity
endcap calorimeter, HGCAL, to be installed later this decade. As part of this
development work, a prototype system was built, with an electromagnetic section
consisting of 14 double-sided structures, providing 28 sampling layers. Each
sampling layer has an hexagonal module, where a multipad large-area silicon
sensor is glued between an electronics circuit board and a metal baseplate. The
sensor pads of approximately 1 cm are wire-bonded to the circuit board and
are readout by custom integrated circuits. The prototype was extensively tested
with beams at CERN's Super Proton Synchrotron in 2018. Based on the data
collected with beams of positrons, with energies ranging from 20 to 300 GeV,
measurements of the energy resolution and linearity, the position and angular
resolutions, and the shower shapes are presented and compared to a detailed
Geant4 simulation
Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20300 GeV/c
The upgrade of the CMS experiment for the high luminosity operation of the
LHC comprises the replacement of the current endcap calorimeter by a high
granularity sampling calorimeter (HGCAL). The electromagnetic section of the
HGCAL is based on silicon sensors interspersed between lead and copper (or
copper tungsten) absorbers. The hadronic section uses layers of stainless steel
as an absorbing medium and silicon sensors as an active medium in the regions
of high radiation exposure, and scintillator tiles directly readout by silicon
photomultipliers in the remaining regions. As part of the development of the
detector and its readout electronic components, a section of a silicon-based
HGCAL prototype detector along with a section of the CALICE AHCAL prototype was
exposed to muons, electrons and charged pions in beam test experiments at the
H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology
as foreseen for the HGCAL but with much finer longitudinal segmentation. The
performance of the calorimeters in terms of energy response and resolution,
longitudinal and transverse shower profiles is studied using negatively charged
pions, and is compared to GEANT4 predictions. This is the first report
summarizing results of hadronic showers measured by the HGCAL prototype using
beam test data.Comment: To be submitted to JINS
- …