    The future of breast radiography: UK perspective

    Get PDF

    Percutaneous sentinel node removal using a vacuum-assisted needle biopsy in women with breast cancer:a feasibility and acceptability study

    Get PDF
    AIMS: To assess the feasibility and acceptability of large-gauge percutaneous removal of the axillary sentinel lymph node (SLN) using dual gamma probe and ultrasound guidance.MATERIALS AND METHODS: Technetium nanocolloid was administered the day before surgery. On the day of surgery, potential SLNs were identified with gamma probe and ultrasound scanning. A 7 G vacuum-assisted biopsy (VAB) device was inserted percutaneously deep to the target node and the node(s) removed. The gamma probe was used to confirm removal of radiolabelled tissue. At surgery, any residual radiolabelled or blue nodes were removed. Morbidity was assessed via (1) a pain questionnaire immediately after the percutaneous procedure, (2) relevant items from the FACT B+4 questionnaire 7-10 days after surgery, and (3) case note review 1 month after surgery.RESULTS: Twenty-two patients consented and 20 patients underwent the procedure. Radiolabelled nodal tissue was obtained in 18/20 (90%). The mean procedure time was 11 minutes. Four of 18 patients had metastatic disease identified in the VAB excision tissue with 100% sensitivity for axillary metastasis. At axillary surgery, additional intact SLN or fragments were found in 14 patients. No additional metastatic disease was found at surgery. One patient suffered a pneumothorax during instillation of local anaesthetic. The median pain score was 10/100 by visual analogue scale. Immediate post-procedure haematoma was common (14 of 20) and prolonged manual compression frequent.CONCLUSION: VAB removal of sentinel nodes using dual scanning is feasible. Although preliminary sensitivity and specificity levels are encouraging, complications may discourage widespread implementation.</p

    Development of an automated detection algorithm for patient motion blur in digital mammograms

    Get PDF
    The purpose is to develop and validate an automated method for detecting image unsharpness caused by patient motion blur in digital mammograms. The goal is that such a tool would facilitate immediate re-taking of blurred images, which has the potential to reduce the number of recalled examinations, and to ensure that sharp, high-quality mammograms are presented for reading. To meet this goal, an automated method was developed based on interpretation of the normalized image Wiener Spectrum. A preliminary algorithm was developed using 25 cases acquired using a single vendor system, read by two expert readers identifying the presence of blur, location, and severity. A predictive blur severity score was established using multivariate modeling, which had an adjusted coefficient of determination, R2 =0.63±0.02, for linear regression against the average reader-scored blur severity. A heatmap of the relative blur magnitude showed good correspondence with reader sketches of blur location, with a Spearman rank correlation of 0.70 between the algorithmestimated area fraction with blur and the maximum of the blur area fraction categories of the two readers. Given these promising results, the algorithm-estimated blur severity score and heatmap are proposed to be used to aid observer interpretation. The use of this automated blur analysis approach, ideally with feedback during an exam, could lead to a reduction in repeat appointments for technical reasons, saving time, cost, potential anxiety, and improving image quality for accurate diagnosis.</p

    Multilingual gendered identities: female undergraduate students in London talk about heritage languages

    Get PDF
    In this paper I explore how a group of female university students, mostly British Asian and in their late teens and early twenties, perform femininities in talk about heritage languages. I argue that analysis of this talk reveals ways in which the participants enact ‘culturally intelligible’ gendered subject positions. This frequently involves negotiating the norms of ‘heteronormativity’, constituting femininity in terms of marriage, motherhood and maintenance of heritage culture and language, and ‘girl power’, constituting femininity in terms of youth, sassiness, glamour and individualism. For these young women, I ask whether higher education can become a site in which they have the opportunities to explore these identifications and examine other ways of imagining the self and what their stories suggest about ‘doing being’ a young British Asian woman in London

    Does shear wave ultrasound independently predict axillary lymph node metastasis in women with invasive breast cancer?

    Get PDF
    Shear wave elastography (SWE) shows promise as an adjunct to greyscale ultrasound examination in assessing breast masses. In breast cancer, higher lesion stiffness on SWE has been shown to be associated with features of poor prognosis. The purpose of this study was to assess whether lesion stiffness at SWE is an independent predictor of lymph node involvement. Patients with invasive breast cancer treated by primary surgery, who had undergone SWE examination were eligible. Data were retrospectively analysed from 396 consecutive patients. The mean stiffness values were obtained using the Aixplorer(®) ultrasound machine from SuperSonic Imagine Ltd. Measurements were taken from a region of interest positioned over the stiffest part of the abnormality. The average of the mean stiffness value obtained from each of two orthogonal image planes was used for analysis. Associations between lymph node involvement and mean lesion stiffness, invasive cancer size, histologic grade, tumour type, ER expression, HER-2 status and vascular invasion were assessed using univariate and multivariate logistic regression. At univariate analysis, invasive size, histologic grade, HER-2 status, vascular invasion, tumour type and mean stiffness were significantly associated with nodal involvement. Nodal involvement rates ranged from 7 % for tumours with mean stiffness <50 kPa to 41 % for tumours with a mean stiffness of >150 kPa. At multivariate analysis, invasive size, tumour type, vascular invasion, and mean stiffness maintained independent significance. Mean stiffness at SWE is an independent predictor of lymph node metastasis and thus can confer prognostic information additional to that provided by conventional preoperative tumour assessment and staging
    • …