58 research outputs found
Weighted Least-Squares Finite Element Method for Cardiac Blood Flow Simulation with Echocardiographic Data
As both fluid flow measurement techniques and computer simulation methods continue to improve, there is a growing need for numerical simulation approaches that can assimilate experimental data into the simulation in a flexible and mathematically consistent manner. The problem of interest here is the simulation of blood flow in the left ventricle with the assimilation of experimental data provided by ultrasound imaging of microbubbles in the blood. The weighted least-squares finite element method is used because it allows data to be assimilated in a very flexible manner so that accurate measurements are more closely matched with the numerical solution than less accurate data. This approach is applied to two different test problems: a flexible flap that is displaced by a jet of fluid and blood flow in the porcine left ventricle. By adjusting how closely the simulation matches the experimental data, one can observe potential inaccuracies in the model because the simulation without experimental data differs significantly from the simulation with the data. Additionally, the assimilation of experimental data can help the simulation capture certain small effects that are present in the experiment, but not modeled directly in the simulation
Impact of pericardial adhesions on diastolic function as assessed by vortex formation time, a parameter of transmitral flow efficiency
<p>Abstract</p> <p>Background</p> <p>Pericardial adhesions are a pathophysiological marker of constrictive pericarditis (CP), which impairs cardiac filling by limiting the total cardiac volume compliance and diastolic filling function. We studied diastolic transmitral flow efficiency as a new parameter of filling function in a pericardial adhesion animal model. We hypothesized that vortex formation time (VFT), an index of optimal efficient diastolic transmitral flow, is altered by patchy pericardial-epicardial adhesions.</p> <p>Methods</p> <p>In 8 open-chest pigs, the heart was exposed while preserving the pericardium. We experimentally simulated early pericardial constriction and patchy adhesions by instilling instant glue into the pericardial space and using pericardial-epicardial stitches. We studied left ventricular (LV) function and characterized intraventricular blood flow with conventional and Doppler echocardiography at baseline and following the experimental intervention.</p> <p>Results</p> <p>Significant decreases in end-diastolic volume, ejection fraction, stroke volume, and late diastolic filling velocity reflected the effects of the pericardial adhesions. The mean VFT value decreased from 3.61 ± 0.47 to 2.26 ± 0.45 (P = 0.0002). Hemodynamic variables indicated the inhibiting effect of pericardial adhesion on both contraction (decrease in systolic blood pressure and +dP/dt decreased) and relaxation (decrease in the magnitude of -dP/dt and prolongation of Tau) function.</p> <p>Conclusion</p> <p>Patchy pericardial adhesions not only negatively impact LV mechanical functioning but the decrease of VFT from normal to suboptimal value suggests impairment of transmitral flow efficiency.</p
Measurement of isotopic separation of argon with the prototype of the cryogenic distillation plant Aria for dark matter searches
The Aria cryogenic distillation plant, located in Sardinia, Italy, is a key component of the DarkSide-20k experimental program for WIMP dark matter searches at the INFN Laboratori Nazionali del Gran Sasso, Italy. Aria is designed to purify the argon, extracted from underground wells in Colorado, USA, and used as the DarkSide-20k target material, to detector-grade quality. In this paper, we report the first measurement of argon isotopic separation by distillation with the 26 m tall Aria prototype. We discuss the measurement of the operating parameters of the column and the observation of the simultaneous separation of the three stable argon isotopes: 36Ar , 38Ar , and 40Ar . We also provide a detailed comparison of the experimental results with commercial process simulation software. This measurement of isotopic separation of argon is a significant achievement for the project, building on the success of the initial demonstration of isotopic separation of nitrogen using the same equipment in 2019
Study on cosmogenic activation above ground for the DarkSide-20k project
The activation of materials due to the exposure to cosmic rays may become an
important background source for experiments investigating rare event phenomena.
DarkSide-20k is a direct detection experiment for galactic dark matter
particles, using a two-phase liquid argon time projection chamber filled with
49.7 tonnes (active mass) of Underground Argon (UAr) depleted in 39Ar. Here,
the cosmogenic activity of relevant long-lived radioisotopes induced in the
argon and other massive components of the set-up has been estimated; production
of 120 t of radiopure UAr is foreseen. The expected exposure above ground and
production rates, either measured or calculated, have been considered. From the
simulated counting rates in the detector due to cosmogenic isotopes, it is
concluded that activation in copper and stainless steel is not problematic.
Activation of titanium, considered in early designs but not used in the final
design, is discussed. The activity of 39Ar induced during extraction,
purification and transport on surface, in baseline conditions, is evaluated to
be 2.8% of the activity measured in UAr from the same source, and thus
considered acceptable. Other products in the UAr such as 37Ar and 3H are shown
to not be relevant due to short half-life and assumed purification methods
Directionality of nuclear recoils in a liquid argon time projection chamber
The direct search for dark matter in the form of weakly interacting massive
particles (WIMP) is performed by detecting nuclear recoils (NR) produced in a
target material from the WIMP elastic scattering. A promising experimental
strategy for direct dark matter search employs argon dual-phase time projection
chambers (TPC). One of the advantages of the TPC is the capability to detect
both the scintillation and charge signals produced by NRs. Furthermore, the
existence of a drift electric field in the TPC breaks the rotational symmetry:
the angle between the drift field and the momentum of the recoiling nucleus can
potentially affect the charge recombination probability in liquid argon and
then the relative balance between the two signal channels. This fact could make
the detector sensitive to the directionality of the WIMP-induced signal,
enabling unmistakable annual and daily modulation signatures for future
searches aiming for discovery. The Recoil Directionality (ReD) experiment was
designed to probe for such directional sensitivity. The TPC of ReD was
irradiated with neutrons at the INFN Laboratori Nazionali del Sud, and data
were taken with 72 keV NRs of known recoil directions. The direction-dependent
liquid argon charge recombination model by Cataudella et al. was adopted and a
likelihood statistical analysis was performed, which gave no indications of
significant dependence of the detector response to the recoil direction. The
aspect ratio R of the initial ionization cloud is estimated to be 1.037 +/-
0.027 and the upper limit is R < 1.072 with 90% confidence levelComment: 20 pages, 10 figures, submitted to Eur. Phys. J.
Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel
Dark matter lighter than 10 GeV/c encompasses a promising range of
candidates. A conceptual design for a new detector, DarkSide-LowMass, is
presented, based on the DarkSide-50 detector and progress toward DarkSide-20k,
optimized for a low-threshold electron-counting measurement. Sensitivity to
light dark matter is explored for various potential energy thresholds and
background rates. These studies show that DarkSide-LowMass can achieve
sensitivity to light dark matter down to the solar neutrino floor for GeV-scale
masses and significant sensitivity down to 10 MeV/c considering the Migdal
effect or interactions with electrons. Requirements for optimizing the
detector's sensitivity are explored, as are potential sensitivity gains from
modeling and mitigating spurious electron backgrounds that may dominate the
signal at the lowest energies
Left Ventricular Flow Analysis: Recent Advances in Numerical Methods and Applications in Cardiac Ultrasound
The left ventricle (LV) pumps oxygenated blood from the lungs to the rest of the body through systemic circulation. The efficiency of such a pumping function is dependent on blood flow within the LV chamber. It is therefore crucial to accurately characterize LV hemodynamics. Improved understanding of LV hemodynamics is expected to provide important clinical diagnostic and prognostic information. We review the recent advances in numerical and experimental methods for characterizing LV flows and focus on analysis of intraventricular flow fields by echocardiographic particle image velocimetry (echo-PIV), due to its potential for broad and practical utility. Future research directions to advance patient-specific LV simulations include development of methods capable of resolving heart valves, higher temporal resolution, automated generation of three-dimensional (3D) geometry, and incorporating actual flow measurements into the numerical solution of the 3D cardiovascular fluid dynamics
- …