514 research outputs found

    Tort Liability of the Media

    Get PDF

    Loss Dependence on Geometry and Applied Power in Superconducting Coplanar Resonators

    Full text link
    The loss in superconducting microwave resonators at low-photon number and low temperatures is not well understood but has implications for achievable coherence times in superconducting qubits. We have fabricated single-layer resonators with a high quality factor by patterning a superconducting aluminum film on a sapphire substrate. Four resonator geometries were studied with resonant frequencies ranging from 5 to 7 GHz: a quasi-lumped element resonator, a coplanar strip waveguide resonator, and two hybrid designs that contain both a coplanar strip and a quasi-lumped element. Transmitted power measurements were taken at 30 mK as a function of frequency and probe power. We find that the resonator loss, expressed as the inverse of the internal quality factor, decreases slowly over four decades of photon number in a manner not merely explained by loss from a conventional uniform spatial distribution of two-level systems in an oxide layer on the superconducting surfaces of the resonator.Comment: 4 pages, 5 figures, Submitted to ASC 2010 conference proceeding

    Direct measurement of the electron-phonon relaxation rate in thin copper films

    Full text link
    We have used normal metal-insulator-superconductor (NIS) tunnel junction pairs, known as SINIS structures, for ultrasensitive thermometry at sub-Kelvin temperatures. With the help of these thermometers, we have developed an ac-technique to measure the electron-phonon (e-p) scattering rate directly, without any other material or geometry dependent parameters, based on overheating the electron gas. The technique is based on Joule heating the electrons in the frequency range DC-10 MHz, and measuring the electron temperature in DC. Because of the nonlinearity of the electron-phonon coupling with respect to temperature, even the DC response will be affected, when the heating frequency reaches the natural cut-off determined by the e-p scattering rate. Results on thin Cu films show a T4T^{4} behavior for the scattering rate, in agreement with indirect measurement of similar samples and numerical modeling of the non-linear response.Comment: to appear in Phys. Stat. Solidi (2005

    Two stage superconducting quantum interference device amplifier in a high-Q gravitational wave transducer

    Full text link
    We report on the total noise from an inductive motion transducer for a gravitational-wave antenna. The transducer uses a two-stage SQUID amplifier and has a noise temperature of 1.1 mK, of which 0.70 mK is due to back-action noise from the SQUID chip. The total noise includes thermal noise from the transducer mass, which has a measured Q of 2.60 X 10^6. The noise temperature exceeds the expected value of 3.5 \mu K by a factor of 200, primarily due to voltage noise at the input of the SQUID. Noise from flux trapped on the chip is found to be the most likely cause.Comment: Accepted by Applied Physics Letters tentatively scheduled for March 13, 200
    • …
    corecore