2 research outputs found

    A Closed-Form Solution of Spatial Sliders for Rigid-Body Guidance

    No full text
    This paper presents a closed-form solution to the four-position synthesis problem by using a spatial slider, which is a spatial dyad of two perpendicularly intersected cylindrical joints. We utilize the dialytic elimination method to simplify the synthesis equations and to obtain a univariate ninth degree polynomial equation. Among the nine sets of solutions, two of them are infinite, and one is the displacement screw from the first position to the second position. Therefore, we have at most six real solutions that can be used to design spatial sliders for the four-position synthesis problem. A numerical example is provided in to demonstrate the validity of the solution procedure

    Differences between CEUS LI-RADS and CECT LI-RADS in the diagnosis of focal liver lesions in patients at risk for HCC

    No full text
    Abstract Objectives To compare the inter-modality consistency and diagnostic performances of the contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS) and contrast-enhanced computed tomography (CECT) LI-RADS in patients at risk for hepatocellular carcinoma (HCC), so as to help clinicians to select a more appropriate modality to follow the focal liver lesions (FLLs). Methods This retrospective study included untreated 277 FLLs from 247 patients who underwent both CEUS and CECT within 1 month. The ultrasound contrast medium used was SonoVue. FLL categories were independently assigned by two ultrasound physicians and two radiologists using CEUS LI-RADS v2017 and CECT LI-RADS v2018, respectively. The diagnostic performances of CEUS and CECT LI-RADS were evaluated using sensitivity, specificity, positive predictive value (PPV), and negative predictive value. Cohen’s Kappa was employed to evaluate the concordance of the LI-RADS category. Results The inter-modality consistency for CEUS and CECT LI-RADS was 0.31 (p < 0.001). HCC was more frequently observed in CECT LR-3 and LR-4 hepatic lesions than in CEUS (7.3% vs. 19.5%, p < 0.001). The specificity and PPV of CEUS and CECT LR-5 for the diagnosis of HCC were 89.5%, 95.0%, and 82.5%, 94.4%, respectively. The sensitivity of CEUS LR-5 + LR-M for the diagnosis of hepatic malignancies was higher than that of CECT (93.7% vs. 82.7%, p < 0.001). The specificity and PPV of CEUS LR-M for the diagnosis of non-HCC malignancies were lower than those of CECT (59.7% vs. 95.5%, p < 0.001; 23.4% vs. 70.3%, p < 0.001). Conclusions The inter-modality consistency between the CEUS and CECT LI-RADS categories is fair. CEUS LI-RADS was more sensitive than CECT LI-RADS in terms of identifying hepatic malignancies, but weaker in terms of separating HCC from non-HCC malignancies
    corecore