43,081 research outputs found
Microscopic resolution broadband dielectric spectroscopy
Results are presented for a non-contact measurement system capable of micron level spatial resolution. It utilises the novel electric potential sensor (EPS) technology, invented at Sussex, to image the electric field above a simple composite dielectric material. EP sensors may be regarded as analogous to a magnetometer and require no adjustments or offsets during either setup or use. The sample consists of a standard glass/epoxy FR4 circuit board, with linear defects machined into the surface by a PCB milling machine. The sample is excited with an a.c. signal over a range of frequencies from 10 kHz to 10 MHz, from the reverse side, by placing it on a conducting sheet connected to the source. The single sensor is raster scanned over the surface at a constant working distance, consistent with the spatial resolution, in order to build up an image of the electric field, with respect to the reference potential. The results demonstrate that both the surface defects and the internal dielectric variations within the composite may be imaged in this way, with good contrast being observed between the glass mat and the epoxy resin
Recommended from our members
Scientific drilling of the Boltysh impact crater, Ukraine
Introduction: The Boltysh crater has been known for several decades and was first drilled in the 1960s as part of a study of economic oil shale deposits. Unfortunately, the cores were not curated and have been lost. We have re-drilled the impact crater and have recovered a near continuous record of ~400 m of organicrich sediments together with 15 m of suevite
Recommended from our members
Organic geochemistry of the crater-fill sediments from Boltysh impact crater, Ukraine
The Boltysh impact crater, is a complex structure formed on the basement rocks of the Ukrainian shield which has been dated at 65.17±0.64 Ma [1]. The Boltysh crater has been know for several decades and was originally drilled in the 1960s-1980s in a study of economic oil shale deposits. Unfortunately, the cores were not curated and have been lost. However we have recently re-drilled the impact crater and have recovered a near continuous record of ~400 m of organic rich sediments deposited in a deep isolated lake which overlie the basement rocks spanning a period ~10 Ma. At 24km diameter, Boltysh will not have contributed substantially to the worldwide devastation at the end of the
Cretaceous. However, the precise age of the Boltysh impact relative to the Chicxulub impact and its location on a stable low lying coastal plain which allowed formation of the postimpact crater lake make it a particularly important locality. After the impact, the crater quickly filled with water in a short marine phase but returned to fresh water which persisted for >10Ma [2]. These strata contain a valuable record of Paleogene environmental change in central Europe, and one of very few terrestrial records of the KT event. This pre-eminent record of the Paleogene can help us to answer several related scientific questions including the relative age of Boltysh compared with Chicxulub, recovery from the impact, and later climate signals. The organic geochemistry and playnology indicate main inputs to be algal and higher plant within most of the core although there are some marked changes in inputs in some sections. A number of carbon isotope excursions are also present within the core which are currently being further investigated
The shape of primordial non-Gaussianity and the CMB bispectrum
We present a set of formalisms for comparing, evolving and constraining
primordial non-Gaussian models through the CMB bispectrum. We describe improved
methods for efficient computation of the full CMB bispectrum for any general
(non-separable) primordial bispectrum, incorporating a flat sky approximation
and a new cubic interpolation. We review all the primordial non-Gaussian models
in the present literature and calculate the CMB bispectrum up to l <2000 for
each different model. This allows us to determine the observational
independence of these models by calculating the cross-correlation of their CMB
bispectra. We are able to identify several distinct classes of primordial
shapes - including equilateral, local, warm, flat and feature (non-scale
invariant) - which should be distinguishable given a significant detection of
CMB non-Gaussianity. We demonstrate that a simple shape correlator provides a
fast and reliable method for determining whether or not CMB shapes are well
correlated. We use an eigenmode decomposition of the primordial shape to
characterise and understand model independence. Finally, we advocate a
standardised normalisation method for based on the shape
autocorrelator, so that observational limits and errors can be consistently
compared for different models.Comment: 32 pages, 20 figure
Primordial non-Gaussianity and the CMB bispectrum
We present a new formalism, together with efficient numerical methods, to
directly calculate the CMB bispectrum today from a given primordial bispectrum
using the full linear radiation transfer functions. Unlike previous analyses
which have assumed simple separable ansatze for the bispectrum, this work
applies to a primordial bispectrum of almost arbitrary functional form, for
which there may have been both horizon-crossing and superhorizon contributions.
We employ adaptive methods on a hierarchical triangular grid and we establish
their accuracy by direct comparison with an exact analytic solution, valid on
large angular scales. We demonstrate that we can calculate the full CMB
bispectrum to greater than 1% precision out to multipoles l<1800 on reasonable
computational timescales. We plot the bispectrum for both the superhorizon
('local') and horizon-crossing ('equilateral') asymptotic limits, illustrating
its oscillatory nature which is analogous to the CMB power spectrum
Dynamical decompactification from brane gases in eleven-dimensional supergravity
Brane gas cosmology provides a dynamical decompactification mechanism that
could account for the number of spacetime dimensions we observe today. In this
work we discuss this scenario taking into account the full bosonic sector of
eleven-dimensional supergravity. We find new cosmological solutions that can
dynamically explain the existence of three large spatial dimensions
characterised by an universal asymptotic scaling behaviour and a large number
of initially unwrapped dimensions. This type of solutions enlarge the possible
initial conditions of the Universe in the Hagedorn phase and consequently can
potentially increase the probability of dynamical decompactification from
anisotropically wrapped backgrounds.Comment: 8 figures, JHEP3 styl
Effective Field Theory Approach to String Gas Cosmology
We derive the 4D low energy effective field theory for a closed string gas on
a time dependent FRW background. We examine the solutions and find that
although the Brandenberger-Vafa mechanism at late times no longer leads to
radion stabilization, the radion rolls slowly enough that the scenario is still
of interest. In particular, we find a simple example of the string inspired
dark matter recently proposed by Gubser and Peebles.Comment: 19 pages, 2 figures, comments adde
X-ray and UV observations of V751 Cyg in an optical high state
Aims: The VY Scl system (anti-dwarf nova) V751 Cyg is examined following a
claim of a super-soft spectrum in the optical low state. Methods: A
serendipitous XMM-Newton X-ray observation and, 21 months later, Swift X-ray
and UV observations, have provided the best such data on this source so far.
These optical high-state datasets are used to study the flux and spectral
variability of V751 Cyg. Results: Both the XMM-Newton and Swift data show
evidence for modulation of the X-rays for the first time at the known 3.467 hr
orbital period of V751 Cyg. In two Swift observations, taken ten days apart,
the mean X-ray flux remained unchanged, while the UV source brightened by half
a magnitude. The X-ray spectrum was not super-soft during the optical high
state, but rather due to multi-temperature optically thin emission, with
significant (10^{21-22} cm^-2) absorption, which was higher in the observation
by Swift than that of XMM-Newton. The X-ray flux is harder at orbital minimum,
suggesting that the modulation is related to absorption, perhaps linked to the
azimuthally asymmetric wind absorption seen previously in H-alpha.Comment: 6 pages, 9 figures, accepted for publication in A&
Diagnosis of Helicobacter pylori by carbon-13 urea breath test using a portable mass spectrometer
CONTEXT: In the non-invasive detection of markers of disease, mass spectrometry is able to detect small quantities of volatile markers in exhaled air. However, the problem of size, expense and immobility of conventional mass spectrometry equipment has restricted its use. Now, a smaller, less expensive, portable quadrupole mass spectrometer system has been developed. Helicobacter pylori has been implicated in the development of chronic gastritis, gastric and duodenal ulcers and gastric cancer. OBJECTIVES: To compare the results obtained from the presence of H. pylori by a carbon-13 urea test using a portable quadrupole mass spectrometer system with those from a fixed mass spectrometer in a hospital-based clinical trial. METHODS: Following ethical approval, 45 patients attending a gastroenterology clinic at the Royal Liverpool University Hospital exhaled a breath sample into a Tedlar gas sampling bag. They then drank an orange juice containing urea radiolabelled with carbon and 30 min later gave a second breath sample. The carbon-13 content of both samples was measured using both quadrupole mass spectrometer systems. If the post-drink level exceeded the pre-drink level by 3% or more, a positive diagnosis for the presence of H. pylori was made. RESULTS: The findings were compared to the results using conventional isotope ratio mass spectrometry using a laboratory-based magnetic sector instrument off-site. The results showed agreement in 39 of the 45 patients. CONCLUSIONS: This study suggests that a portable quadrupole mass spectrometer is a potential alternative to the conventional centralised testing equipment. Future development of the portable quadrupole mass spectrometer to reduce further its size and cost is indicated, together with further work to validate this new equipment and to enhance its use in mass spectrometry diagnosis of other medical conditions
- …