52 research outputs found

    Single-Shot Detection of Neurotransmitters in Whole-Blood Samples by Means of the Heat-Transfer Method in Combination with Synthetic Receptors.

    Get PDF
    Serotonin is an important neurotransmitter that plays a major role in the pathogenesis of a variety of conditions, including psychiatric disorders. The detection of serotonin typically relies on high-performance liquid chromatography (HPLC), an expensive technique that requires sophisticated equipment and trained personnel, and is not suitable for point-of-care applications. In this contribution, we introduce a novel sensor platform that can measure spiked neurotransmitter concentrations in whole blood samples in a fast and low-cost manner by combining synthetic receptors with a thermal readout technique-the heat-transfer method. In addition, the design of a miniaturized version of the sensing platform is presented that aims to bridge the gap between measurements in a laboratory setting and point-of-care measurements. This fully automated and integrated, user-friendly design features a capillary pumping unit that is compatible with point-of-care sampling techniques such as a blood lancet device (sample volume-between 50 µL and 300 µL). Sample pre-treatment is limited to the addition of an anti-coagulant. With this fully integrated setup, it is possible to successfully discriminate serotonin from a competitor neurotransmitter (histamine) in whole blood samples. This is the first demonstration of a point-of-care ready device based on synthetic receptors for the screening of neurotransmitters in complex matrices, illustrating the sensor's potential application in clinical research and diagnosis of e.g., early stage depression

    Label-free protein detection based on the heat-transfer method-a case study with the peanut allergen Ara h 1 and aptamer-based synthetic receptors

    Get PDF
    © 2015 American Chemical Society. Aptamers are an emerging class of molecules that, because of the development of the systematic evolution of ligands by exponential enrichment (SELEX) process, can recognize virtually every target ranging from ions, to proteins, and even whole cells. Although there are many techniques capable of detecting template molecules with aptamer-based systems with high specificity and selectivity, they lack the possibility of integrating them into a compact and portable biosensor setup. Therefore, we will present the heat-transfer method (HTM) as an interesting alternative because this offers detection in a fast and low-cost manner and has the possibility of performing experiments with a fully integrated device. This concept has been demonstrated for a variety of applications including DNA mutation analysis and screening of cancer cells. To the best our knowledge, this is the first report on HTM-based detection of proteins, in this case specifically with aptamer-type receptors. For proof-of-principle purposes, measurements will be performed with the peanut allergen Ara h 1 and results indicate detection limits in the lower nanomolar regime in buffer liquid. As a first proof-of-application, spiked Ara h 1 solutions will be studied in a food matrix of dissolved peanut butter. Reference experiments with the quartz-crystal microbalance will allow for an estimate of the areal density of aptamer molecules on the sensor-chip surface

    Baseline characteristics of patients in the reduction of events with darbepoetin alfa in heart failure trial (RED-HF)

    Get PDF
    <p>Aims: This report describes the baseline characteristics of patients in the Reduction of Events with Darbepoetin alfa in Heart Failure trial (RED-HF) which is testing the hypothesis that anaemia correction with darbepoetin alfa will reduce the composite endpoint of death from any cause or hospital admission for worsening heart failure, and improve other outcomes.</p> <p>Methods and results: Key demographic, clinical, and laboratory findings, along with baseline treatment, are reported and compared with those of patients in other recent clinical trials in heart failure. Compared with other recent trials, RED-HF enrolled more elderly [mean age 70 (SD 11.4) years], female (41%), and black (9%) patients. RED-HF patients more often had diabetes (46%) and renal impairment (72% had an estimated glomerular filtration rate <60 mL/min/1.73 m2). Patients in RED-HF had heart failure of longer duration [5.3 (5.4) years], worse NYHA class (35% II, 63% III, and 2% IV), and more signs of congestion. Mean EF was 30% (6.8%). RED-HF patients were well treated at randomization, and pharmacological therapy at baseline was broadly similar to that of other recent trials, taking account of study-specific inclusion/exclusion criteria. Median (interquartile range) haemoglobin at baseline was 112 (106–117) g/L.</p> <p>Conclusion: The anaemic patients enrolled in RED-HF were older, moderately to markedly symptomatic, and had extensive co-morbidity.</p&gt

    Non-Isolated DC-DC Converters in Fuel Cell Applications: Thermal Analysis and Reliability Comparison

    No full text
    An alternative energy source that has appeared beyond expectations and has seen a lot of progress is the fuel cell. A proton exchange membrane (PEM) fuel cell is chosen for analysis and requires a DC-DC boost converter as an interface between the fuel cell and the load to provide a high-gain regulated voltage. Although great effort towards developing different converter topologies has been made during recent decades, less attention has been devoted to the reliability and thermal performance assessment of the present converters. In this paper, five non-isolated DC-DC converters are analyzed in terms of both thermal behavior and reliability. The temperature estimation of semiconductor devices as a critical part of the thermal analysis has been made via a detailed thermal model and the reliability is evaluated by means of a power cycling test. Finally, a performance score has been attributed using the TOPSIS ranking methodology and considering all the criteria (e.g., the number of components and cost) at the same time. The results indicated that the floating interleaved boost converter is always at the top of the list, even if the weight of the indicators is changed. When the weight of the cost criterion is higher than the reliability criterion, the multi-switch boost converter will be in second place. If the weight of the reliability criterion is greater than cost, the interleaved and multi-switch converter are ranked second and third, respectively. Additionally, the Cuk converter with a closeness coefficient of zero is always associated with the most unfavorable performance

    Assessing the impact of PV panel climate-based degradation rates on inverter reliability in grid-connected solar energy systems

    No full text
    This paper provides an evaluation of a 4-kW grid-connected full-bridge PV inverter under three different scenarios to assess its reliability with a fixed PV degradation rate, with a climate-based degradation rate, and without considering PV degradation. The climate-based degradation rates are estimated using a physics-based model that considers the different parameters influencing the PV reliability. Three different locations representing three different climate zones (hot and dry, hot and humid, and moderate climates) have been chosen in this study. The estimated lifetime of the IGBT, the switching device in the PV inverter, varies depending on the location, with the inclusion of fixed and climate-based degradation rates extending the lifespan of the PV inverter in the examined locations. The results demonstrate the significant impact of PV climate-based degradation rates on power electronics' reliability assessment and the importance of considering various factors in predicting device failures. To ensure the PV inverter's lifespan over the desired period in areas with high solar irradiation rates and extremely hot climates, the design parameters should be slightly elevated above the standard value

    Carbon capture and utilization for industrial applications

    No full text
    Heavy industries such as cement, iron and steel, oil refining, and petrochemicals are responsible for about 22% of global carbon dioxide (CO2) emissions. There exist several pathways for global CO2 mitigation. Capturing, storage, and utilization of CO2 (CCS and CCU) provide an operational solution for significant emission mitigation. High purity CO2 streams are the most interesting points for CCS and CCU. Pure CO2 streams are suitable for compression, transport, and storage. Capture technology categories are typically pre-combustion, oxy-fuel combustion, and post-combustion processes. Moreover, the main challenges of the robust industrial CCS/U development are the high costs of CO2 separation from flue gas or ambient air and the conversion of CO2 in various utilization pathways. This research study includes a summary of several CCS technologies and CCU pathways, their current status, cost, and industrial deployment

    Combining Electrochemical Impedance Spectroscopy and Surface Plasmon Resonance into one Simultaneous Read-Out System for the Detection of Surface Interactions

    No full text
    In this article we describe the integration of impedance spectroscopy (EIS) and surface plasmon resonance (SPR) into one surface analytic device. A polydimethylsiloxane (PDMS) flow cell is created, matching the dimensions of a commercially available sensor chip used for SPR measurements. This flow cell allowed simultaneous measurements between an EIS and a SPR setup. After a successful integration, a proof of principle study was conducted to investigate any signs of interference between the two systems during a measurement. The flow cell was rinsed with 10 mM Tris-HCl and 1× PBS buffer in an alternating manner, while impedance and shifts of the resonance angle were monitored. After achieving a successful proof of principle, a usability test was conducted. It was assessed whether simultaneous detection occurred when: (i) Protein A is adsorbed to the gold surface of the chip; (ii) The non-occupied zone is blocked with BSA molecules and (iii) IgG1 is bound to the Protein A. The results indicate a successful merge between SPR and EIS.status: publishe

    Cell proliferation monitoring by multiplexed electrochemical impedance spectroscopy on microwell assays

    No full text
    Cell proliferation can be monitored by a wide range of well-established techniques. Most of the principles used rely on optical, single end-point methods, often involving the use of absorbent, fluorescent or luminescent compounds. These additives can interfere with the cell growth, thus producing distorted results. Electrochemical impedance spectroscopy provides a solution for this problem and enables continuous monitoring without interference. However equipment for this measurement technique is often bulky, highly expensive and lacks multichannel features. This paper presents a low-cost, compact hardware platform optimized for proliferation measurements, together with custom software to ease interpretation and physical modelling of data. Performance is demonstrated and measurement parameters are fine-tuned for three commonly used cell types in proliferation measurements. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.status: publishe
    corecore