80 research outputs found

    Signal Improvement for Underwater LIBS

    Get PDF
    We employed a collinear long-short double-pulse laser induced breakdown spectroscopy (LS-DP-LIBS) to detect the underwater metal samples. The emission spectra, time-resolved signal, plasma images and sound characteristics of plasma shockwaves are experimentally investigated in this work. The results show that the underwater signal of Al, Cu and Fe spectral lines are significantly improved by collinear LS-DP-LIBS with inter-pulse delay of 35 us. The mechanism of the signal improvement is considered to be the pre irradiation effect of the long pulse laser beam. In the collinear LS-DP-LIBS method, the long pulse first generates a cavitation bubble in water and provides a gaseous environment. Then the short pulse generates the plasma from the sample surface. The present experiments show that the collinear LS-DP-LIBS method offers a significant signal improvement in underwater measurement of metal samples. This new method has great potential in deep-sea exploration using LIBS

    Efficacy of Intra-Articular Injection of Celecoxib in a Rabbit Model of Osteoarthritis

    Get PDF
    Introduction: Osteoarthritis is the most common form of arthritis. It is a slowly progressive joint disease typically seen in middle-age to elderly people. Intra-articular injection of hyaluronic acid is a well-documented treatment for knee osteoarthritis. Celebrex® (celecoxib) is a novel nonsteroidal anti-inflammatory drug, which could help to reduce inflammation and to reduce pain. The aim of this study was to evaluate the effects of intra-articular injection of celecoxib in a rabbit osteoarthritis model. Methods: Thirty New Zealand white rabbits underwent unilateral knee joint surgery using the Hulth technique. Six weeks post-surgery, the animals were randomly divided into three groups, and each group was respectively given weekly intra-articular injections with Celebrex®, hyaluronic acid and saline. On the sixth week, the results were assessed in rabbit models by gross observation, histological evaluation, and expression of IL-1β, TNF-α, MMP-3. Results: In the group given Celebrex® and hyaluronic acid, the pathological changes in the rabbit articular cartilage improved significantly, much more than in the saline group. The statistically significant suppression of IL-1β, TNF-α, MMP-3 was shown in the Celebrex group. No significant differences were detected between two treatment groups. Conclusions: Intra-articular injection of celecoxib is beneficial for knee osteoarthritis. It might repair and protect early osteoarthritis cartilage by delaying cartilage degeneration and impairing the function of inflammatory mediators, therefore, intra-articular injection of celecoxib can be used as an alternative to the current treatment of osteoarthritis

    Safety of HIF prolyl hydroxylase inhibitors for anemia in dialysis patients: a systematic review and network meta-analysis

    Get PDF
    Aim: We performed a systematic review and network meta-analysis evaluating the safety and efficacy of hypoxia-inducible factor prolyl hydroxylase inhibitors (HIF-PHIs) among dialysis chronic kidney disease patients.Methods: Safety was evaluated with any adverse events (AEs), serious adverse events (SAEs), and 12 common events. Efficacy was mainly analyzed with hemoglobin response. All reported results were summarized using mean difference and risk ratio (RR) with 95% confidence interval (CI). Publication bias was assessed through funnel plots.Results: Twenty trials (19 studies) with 14,947 participants were included, comparing six HIF-PHIs with erythropoiesis-stimulating agents (ESAs). No significant differences were indicated in overall AEs and SAEs between each HIF-PHI and ESA. The occurrence of gastrointestinal disorder was higher in enarodustat and roxadustat than in ESAs (RR: 6.92, 95% CI: 1.52–31.40, p = 0.01; RR: 1.30, 95% CI: 1.04–1.61, p = 0.02). The occurrence of hypertension was lower in vadadustat than in ESAs (RR: 0.81, 95% CI: 0.69–0.96, p = 0.01). The occurrence of vascular-access complications was higher in roxadustat (RR: 1.15, 95% CI: 1.04–1.27, p<0.01) and lower in daprodustat (RR: 0.78, 95% CI: 0.66–0.92, p<0.01) than in ESAs. In the risk of the other nine events, including cardiovascular events, no significant differences were observed between HIF-PHIs and ESAs. For hemoglobin response, network meta-analysis showed that compared with ESAs, significant increases were shown in roxadustat (RR: 1.04, 95% CI: 1.01–1.07, p<0.01) and desidustat (RR: 1.22, 95% CI: 1.01–1.48, p = 0.04), whereas noticeable reductions were indicated in vadadustat (RR: 0.88, 95% CI: 0.82–0.94, p<0.01) and molidustat (RR: 0.83, 95% CI: 0.70–0.98, p = 0.02). There was no significant difference between daprodustat and ESAs (RR: 0.97, 95% CI: 0.89–1.06, p = 0.47).Conclusion: Although HIF-PHIs did not show significant differences from ESAs in terms of overall AEs and SAEs, statistical differences in gastrointestinal disorder, hypertension, and vascular-access complications were observed between HIF-PHIs, which deserved to be noted in clinical decision making.Systematic review registration: This study is registered with PROSPERO (registration number CRD42022312252

    Transcatheter Versus Surgical Closure of Perimembranous Ventricular Septal Defects in Children A Randomized Controlled Trial

    Get PDF
    ObjectivesThe objective of this study was to evaluate the safety and efficacy of the surgical versus transcatheter approach to correct perimembranous ventricular septal defects (pmVSDs) in a prospective, randomized, controlled clinical trial.BackgroundpmVSD is a common congenital heart disease in children. Surgical closure of pmVSD is a well-established therapy but requires open-heart surgery with cardiopulmonary bypass. Although the transcatheter approach is associated with significant incidence of complete atrioventricular block, it may provide a less invasive alternative. Critical comparison of the safety and efficacy of the 2 interventions necessitates a prospective, randomized, controlled trial.MethodsBetween January 2009 and July 2010, 229 children with pmVSD were randomly assigned to surgical or transcatheter intervention. Clinical, laboratory, procedural, and follow-up data over a 2-year period were compared.ResultsNeither group had mortality or major complications. However, statistical analysis of the 2 groups demonstrated significant differences (p < 0.001) in minor adverse events (32 vs. 7), quantity of blood transfused, duration of the procedure, median hospital stay, median intensive care unit stay, median hospitalization cost, and median blood loss. During a median follow-up of 2 years, the left ventricular end-diastolic dimension of both groups returned to normal and there was no difference in closure rate, adverse events, and complications between groups.ConclusionsTranscatheter device closure and surgical repair are effective interventions with excellent midterm results for treating pmVSD in children. Transcatheter device closure has a lower incidence of myocardial injury, less blood transfused, faster recovery, shorter hospital stay, and lower medical expenses. (Transcatheter Closure Versus Surgery of Perimembranous Ventricular Septal Defects; NCT00890799

    Cutting Force Transition Model Considering the Influence of Tool System by Using Standard Test Table

    No full text
    The cutting force prediction model usually uses the classical oblique transformation method, which introduces the orthogonal cutting parameters into the oblique milling edge shape, and combines the geometric parameters of the tool to convert the orthogonal cutting force into the actual cutting force, thereby predicting the cutting force. However, this cutting force prediction method ignores the impact of tool vibration in actual machining, resulting in a large difference between the prediction model and the actual measurement. This paper proposes a cutting force conversion model considering the influence of the tool system. The proposed model fully considers the impact of tool vibration on the cutting force. On the basis of the orthogonal model, superimposing the additional cutting force generated by tool vibration makes the predicted value of the model closer to the actual cutting force. The results of milling experiments show that the conversion model can obtain higher prediction accuracy. Moreover, compared with the original conversion model, the accuracy of the proposed model is significantly improved

    An integration system for investment An integration system for investment turbine blade

    No full text
    An integration system was developed to satisfy the need of information integration in the process of designing, investment casting and monitoring aero-engine’s turbo blade. The general architecture is detailed presented in this paper. The system mainly comprises of product master model, design information management, anti-deformation design of mould cavity, intelligence mould design and blade testing. The developed system can manage mould design and blade test data fl ow, optimize mould design process and achieve the goal of integration design

    Energy Consumption Model for Drilling Processes Based on Cutting Force

    No full text
    Accurate energy consumption modelling is critical for the improvement of energy efficiency in machining. Existing energy models of machining processes mainly focus on turning or milling, and there are few energy models for drilling. However, since drilling is often applied to roughing and semi-finishing, and the cutting parameters are large, the energy consumption is huge, and it is urgent to study the consumption of energy during the drilling process. In this paper, an energy consumption model for drilling processes was proposed. Idle power, cutting power, and auxiliary power were included in the proposed energy consumption model, using the cutting force to obtain the cutting power during drilling. Further, the relationship between cutting power and auxiliary power was analyzed. Cutting experiments were then carried out which confirmed the correctness of the proposed model. In addition, compared with several existing energy consumption models, the proposed model had better accuracy and applicability. It is expected that the proposed energy consumption model will have applications for the minimization of energy consumption and improvement of energy efficiency but not limited to only drilling energy consumption prediction
    • …
    corecore