446 research outputs found
The Interpersonal Circumplex and the Five-Factor Theory of personality as frames of reference
This article reviews existing approaches to defining and distinguishing
communication styles and proposes a common frame of reference for future
research. The literature review yields two schools of thought: the behavior-
centered perspective and the personality-oriented perspective. Although these
lines of research differ in their ways of defining communication styles, they
show considerable similarities with respect to their classification. Many
researchers build their taxonomies on two key dimensions: assertiveness and
responsiveness. We propose embedding communication styles into the Five-Factor
Theory (FFT) and defining them as characteristic adaptations of personality.
We also suggest the Interpersonal Circumplex (IPC) as a reference model for
distinguishing communication styles as it is able to integrate substantial
dimensions and facets of existing taxonomies in a parsimonious way
Dark states of single NV centers in diamond unraveled by single shot NMR
The nitrogen-vacancy (NV) center in diamond is supposed to be a building
block for quantum computing and nanometer scale metrology at ambient
conditions. Therefore, precise knowledge of its quantum states is crucial.
Here, we experimentally show that under usual operating conditions the NV
exists in an equilibrium of two charge states (70% in the expected negative
(NV-) and 30% in the neutral one (NV0)). Projective quantum non-demolition
measurement of the nitrogen nuclear spin enables the detection even of the
additional, optically inactive state. The nuclear spin can be coherently driven
also in NV0 (T1 ~ 90 ms and T2 ~ 6 micro-s).Comment: 4 pages, 3 figure
The clinical value of [90Y-DOTA]-D-Phe1-Tyr3-octreotide (90Y-DOTATOC) in the treatment of neuroendocrine tumours: A clinical phase II study
Purpose: The aim of this phase II study was to evaluate the tumour response of neuroendocrine tumours to targeted irradiation with the radiolabelled somatostatin analogue 90Y-DOTATOC. In addition, the palliative effect of 90-Y-DO-TATOC treatment on the malignant carcinoid syndrome and tumour-associated pain was investigated. Patients and methods: Forty-one patients (mean age 53 years) with neuroendocrine gastroenteropancreatic and bronchial tumours were included. Eighty-two percent of the patients had therapy resistant and progressive disease. The treatment con sisted of four intravenous injections ofa total of 6000 MBq/m2 90Y-DOTATOC, administered at intervals of six weeks. Results:The overall response rate was 24%. For endocrine pancreatic tumours it was 36%. Complete remissions (CR) were found in 2% (1 of 41), partial remissions (PR) in 22% (9 of 41), minor response in 12% (5 of 41), stable disease (SD) in 49% (20 of4l) and progressive disease (PD) in 15% (6 of4l). The median follow up was 15 months (range 1 month to 36 months). The median duration of response has not been reached at 26 months. The two-year survival time was 76 ± 16%. Eighty-three percent of the patients suffering from the malignant carcinoid syndrome achieved a significant reduction of symptoms. The treatment was well tolerated. A reduction of pain score was observed in all patients (5 of 41) with morphine dependent tumour-associated pain. Side effects included grade LU (NCIGC) pancytopenia in 5%, and vomiting shortly after injection in 23%. No grade III—IV renal toxicity was observed. Conclusion: Targeted radiotherapy with 90Y-DOTATOC is a novel, well-tolerated treatment for neuroendocrine turnours with a remarkable objective response rate, survival time, and symptomatic respons
A comparison of 111In-DOTATOC and 111In-DOTATATE: biodistribution and dosimetry in the same patients with metastatic neuroendocrine tumours
[Yttrium-90-DOTA-Tyr3]-octreotide (DOTATOC) and [177Lu-DOTA-Tyr3-Thr8]-octreotide (DOTATATE) are used for peptide receptor-mediated radionuclide therapy (PRMRT) in neuroendocrine tumours. No human data comparing these two compounds are available so far. We used 111In as a surrogate for 90Y and 177Lu and examined whether one of the 111In-labelled peptides had a more favourable biodistribution in patients with neuroendocrine tumours. Special emphasis was given to kidney uptake and tumour-to-kidney ratio since kidney toxicity is usually the dose-limiting factor. Five patients with metastatic neuroendocrine tumours were injected with 222MBq 111In-DOTATOC and 111In-DOTATATE within 2 weeks. Up to 48h after injection, whole-body scans were performed and blood and urine samples were collected. The mean absorbed dose was calculated for tumours, kidney, liver, spleen and bone marrow. In all cases 111In-DOTATATE showed a higher uptake (%IA) in kidney and liver. The amount of 111In-DOTATOC excreted into the urine was significantly higher than for 111In-DOTATATE. The mean absorbed dose to the red marrow was nearly identical. 111In-DOTATOC showed a higher tumour-to-kidney absorbed dose ratio in seven of nine evaluated tumours. The variability of the tumour-to-kidney ratio was high and the significance level in favour of 111In-DOTATOC was P=0.065. In five patients the pharmacokinetics of 111In-DOTATOC and 111In-DOTATATE was found to be comparable. The two peptides appear to be nearly equivalent for PRMRT in neuroendocrine tumours, with minor advantages for 111In/90Y-DOTATOC; on this basis, we shall continue to use 90Y-DOTATOC for PRMRT in patients with metastatic neuroendocrine tumour
Opening up the Quantum Three-Box Problem with Undetectable Measurements
One of the most striking features of quantum mechanics is the profound effect
exerted by measurements alone. Sophisticated quantum control is now available
in several experimental systems, exposing discrepancies between quantum and
classical mechanics whenever measurement induces disturbance of the
interrogated system. In practice, such discrepancies may frequently be
explained as the back-action required by quantum mechanics adding quantum noise
to a classical signal. Here we implement the 'three-box' quantum game of
Aharonov and Vaidman in which quantum measurements add no detectable noise to a
classical signal, by utilising state-of-the-art control and measurement of the
nitrogen vacancy centre in diamond.
Quantum and classical mechanics then make contradictory predictions for the
same experimental procedure, however classical observers cannot invoke
measurement-induced disturbance to explain this discrepancy. We quantify the
residual disturbance of our measurements and obtain data that rule out any
classical model by > 7.8 standard deviations, allowing us for the first time to
exclude the property of macroscopic state-definiteness from our system. Our
experiment is then equivalent to a Kochen-Spekker test of quantum
non-contextuality that successfully addresses the measurement detectability
loophole
Composite-pulse magnetometry with a solid-state quantum sensor
The sensitivity of quantum magnetometers is challenged by control errors and,
especially in the solid-state, by their short coherence times. Refocusing
techniques can overcome these limitations and improve the sensitivity to
periodic fields, but they come at the cost of reduced bandwidth and cannot be
applied to sense static (DC) or aperiodic fields. Here we experimentally
demonstrate that continuous driving of the sensor spin by a composite pulse
known as rotary-echo (RE) yields a flexible magnetometry scheme, mitigating
both driving power imperfections and decoherence. A suitable choice of RE
parameters compensates for different scenarios of noise strength and origin.
The method can be applied to nanoscale sensing in variable environments or to
realize noise spectroscopy. In a room-temperature implementation based on a
single electronic spin in diamond, composite-pulse magnetometry provides a
tunable trade-off between sensitivities in the microT/sqrt(Hz) range,
comparable to those obtained with Ramsey spectroscopy, and coherence times
approaching T1
- …