3 research outputs found

    A case where rocuronium was unable to achieve neuromuscular block immediately after sugammadex administration

    Get PDF
    We present a case where immediatemuscle relaxation was needed following sugammadex administration. A 72 year-old female underwent surgery for a cerebral artery aneurysm. Upon conclusion of the operation sugammadex (9.3 mg/kg) was administered and the patient was noted to have left hemiplegia. Rocuronium (1.2 mg/kg 2 doses) was given in order to gain neuromuscular block approximately 25 minutes after sugammadex had been injected. Although TOF monitoring was not utilized in this case and assessing residual muscular block was difficult, spontaneous respirations continued and breathing had to be controlled with sevoflurane and remifentanil. Sugammadex is a potent reversal agent for rocuronium-induced neuromuscular block, however, certain situations require immediate neuromuscular blockade following sugammadex. In this case, rocuronium was unable to induce neuromuscular blockade immediately after sugammadex and that higher concentrations were necessary in addition to intravenous analgesics and inhaled anesthetics

    Usefulness of central venous oxygen saturation monitoring during bidirectional Glenn shunt

    Get PDF
    A PediaSat(TM) oximetry catheter (PediaSat : Edwards Lifesciences Co., Ltd., Irvine, CA, U.S.A.), which facilitates continuous measurement of central venous oxygen saturation (ScvO2), may be useful for surgery for pediatric congenital heart disease. We used PediaSat during a bidirectional Glenn shunt. The patient was a 13-month-old boy. Under a diagnosis of left single ventricle (pulmonary atresia, right ventricular hypoplasia, atrial septal defect) and residual left aortic arch/left superior vena cava, a modified right Blalock- Taussig shunt was performed. Cyanosis deteriorated, so a bidirectional Glenn shunt was scheduled. After anesthesia induction, a 4.5 Fr double-lumen (8 cm) PediaSat was inserted through the right internal jugular vein for continuous ScvO2 monitoring. Furthermore, the probe of a near-infrared, mixed blood oxygen saturation-measuring monitor was attached to the forehead for continuous monitoring of the regional brain tissue mixed blood oxygen saturation (rSO2) (INVOS(TM) 5100C, Covidien ; Boulder, CO, U.S.A.). Blockage of the right pulmonary artery and right superior vena cava decreased the oxygen saturation, ScvO2, and rSO2, but increased the central venous pressure. Although changes in ScvO2 were parallel to those in rSO2, the former showed more marked changes. A combination of ScvO2 and rSO2 for monitoring during Glenn shunt may be safer

    Recent Less-invasive Circulatory Monitoring during Renal Transplantation

    Get PDF
    For anesthetic management during renal transplantation, it is necessary to maintain the blood flow and function of the transplanted kidney by performing massive fluid management and stabilizing blood pressure. We report anesthetic management for renal transplantation with a less-invasive circulatory monitoring system (Edwards Life Sciences Co., Ltd., Irvine, California, U.S.A.). In November 2010, renal transplantation was started in our hospital, and performed in 6 patients. In the first patient, fluid/circulatory management was conducted by connecting a standard arterial line and a standard central venous (CV) line. In the second patient, a FloTracTM system and a standard CV line were used. In the third patient, a standard arterial line and a PreSepTM CV Oximetry Catheter were used. In the fourth and fifth patients, a FloTracTM and a PreSepTM were used. In the latest patient, FloTracTM and PreSepTM were connected to an EV1000TM Clinical Platform for fluid/circulatory management. The establishment of high-visibility monitors was useful for evaluating the condition and confirming the effects. As there are marked changes in hemodynamics, the CV pressure, which has been used as a parameter of fluid management, is not reliable in renal failure patients with a high incidence of cardiovascular complications. Advances in noninvasive circulatory monitoring with dynamic indices may improve the safety of anesthetic management during renal transplantation
    corecore